Choose a country or area to see content specific to your location
尋找感興趣的產品?
Bridging design and physical testing to evaluate drop, impact, shock, and vibration compliance before hardware exists.
Unlock your free upgrade to the next bandwidth tier.
Strengthen 1.6T network reliability for AI-scale workloads from transceivers to interconnects.
Pair Keysight VSA software with the new XA5 signal analyzer for advanced visualization, demodulation, and analysis — start your 30-day trial today.
With extra memory and storage, these enhanced NPBs run Keysight's AI security and performance monitoring software and AI stack.
Explore end-to-end workflows spanning IC design, validation, wafer test, and photonics.
Explore curated support plans, prioritized to keep you innovating at speed.
Maximize accuracy and performance with precision accessories engineered for Keysight instruments.
Explore dual-channel and ultra-wideband signal analysis for demanding RF workflows.
Get faster, clearer insights with our new multicore, 12-bit oscilloscope up to 33 GHz. Trade in your old oscilloscope and get credit toward a new XR8.
Authoritative application notes, data sheets, reference designs, and test procedures to accelerate design and validation decisions.
Hands‑on bootcamps that teach system design, test methods, and production workflows engineers can apply immediately.
Success Stories
Explore the complete portfolio of Keysight accessories designed to complement and extend your instruments. Use the filters below to quickly find compatible accessories such as modules, cables, adapters, and other system components to configure, expand, and optimize your test system for your specific measurement needs.
No Filter available
No Filter available
No Filter available
N2125A
Calibrate one or more channels of your 80 to 110 GHz UXR oscilloscopes, achieving a full factory quality frame calibration
The Infiniium UXR-Series is the first real-time oscilloscope to offer an optional self-optimization module – capable of performing the frame adjustments to align internal correction constants under site environmental conditions. Optimization modules are available for all UXR-Series bulkhead connector types and supported bandwidths.
A full factory certified calibration consists of frame calibration adjustments, and subsequent testing and performance verification to ensure the oscilloscope is performing to its documented specifications. The optimization module performs only the factory-quality frame adjustment calibration steps. Additional instruments and components are necessary to perform the required horizontal adjustments and vertical performance verification procedures to achieve a full self-verified calibration. If an accredited certified calibration certificate is required, the UXR must be returned to a qualified Keysight service center.
N2126A
Calibrate one or more channels of your 40 to 70 GHz UXR oscilloscopes, achieving a full factory quality frame calibration.
為確保您的高效能量測設備在運作時達到其規定的效能,您需要定期進行校驗。但是,一年一度的校驗在時間上可能正好與您的運作相衝突,進而影響專案進度或生產效率。Infiniium UXR 系列提供選配的自校驗套件,能夠執行完整的出廠級主機校驗。您再也不需要將 Infiniium UXR 系列示波器送出去校驗,可避免運作效率或時間上的損失。
利用 N2126A -- UXR 的 1.85 mm 校驗套件,您可以校驗 40 至 70 GHz UXR 示波器的一個或多個通道。它能在與您的待測裝置相同的環境條件下,執行完整的出廠級主機校驗。磷化銦(InP)晶片可在校驗通道時產生高速步進。透過附加設備,您還可以選擇提供時間刻度校驗。隨校驗套件一同提供的還包括校驗證書、3.5 mm 母頭至母頭轉接器、40 GHz 50 Ω SK-直通-公頭 SK-直通-公頭同軸纜線。
N2127A
Calibrate one or more channels of your 13 to 33 GHz UXR oscilloscopes, achieving a full factory quality frame calibration.
為確保您的高效能量測設備在運作時達到其規定的效能,您需要定期進行校驗。但是,一年一度的校驗在時間上可能正好與您的運作相衝突,進而影響專案進度或生產效率。Infiniium UXR 系列提供選配的自校驗套件,能夠執行完整的出廠級主機校驗。您再也不需要將 Infiniium UXR 系列示波器送出去校驗,可避免運作效率或時間上的損失。
利用 N2127A -- UXR 的 3.5 mm 校驗套件,您可以校驗 13 至 33 GHz UXR 示波器的一個或多個通道。它能在與您的待測裝置相同的環境條件下,執行完整的出廠級主機校驗。磷化銦(InP)晶片可在校驗通道時產生高速步進。透過附加設備,您還可以選擇提供時間刻度校驗。隨校驗套件一同提供的還包括校驗證書、3.5 mm 母頭至母頭轉接器、40 GHz 50 Ω SK-直通-公頭 SK-直通-公頭同軸纜線。
85058G
Keysight’s 85058G 1.85 mm data-based mechanical calibration kit calibrates the measurement setups using Keysight’s vector network analyzer for the devices under test with 1.85 mm connectors. The 85058G uses new data-based models and Option CDA provides better directivity performance than traditional mechanical calibration using polynomial models.
Option CDA provides characterized data specific to the serial number of the calibration kit to
Designed exclusively for Keysight's vector network analyzers
85056G
Keysight’s 85056G 2.4 mm data-based mechanical calibration kit calibrates the measurement setups using Keysight’s vector network analyzer for the devices under test with 2.4 mm connectors. The 85056G uses new data-based models and Option CDA provides better directivity performance than traditional mechanical calibration using polynomial models.
Option CDA provides characterized data specific to the serial number of the calibration kit to
Designed exclusively for Keysight's vector network analyzers
85055G
Keysight’s 85055G 2.92 mm data-based mechanical calibration kit calibrates the measurement setups using Keysight’s vector network analyzer for the devices under test with 2.92 mm connectors. The 85052G uses new data-based models and Option CDA provides better directivity performance than traditional mechanical calibration using polynomial models.
Option CDA provides characterized data specific to the serial number of the calibration kit to
Designed exclusively for Keysight's vector network analyzers
85054G
Keysight’s 85054G Type-N data-based mechanical calibration kit calibrates the measurement setups using Keysight’s vector network analyzer for the devices under test with Type-N connectors. The 85054G uses new data-based models and Option CDA provides better directivity performance than traditional mechanical calibration using polynomial models.
Option CDA provides characterized data specific to the serial number of the calibration kit to
Designed exclusively for Keysight's vector network analyzers
85052G
Keysight’s 85052G 3.5 mm data-based mechanical calibration kit calibrates the measurement setups using Keysight’s vector network analyzer for the devices under test with 3.5 mm connectors. The 85052G uses new data-based models and Option CDA provides better directivity performance than traditional mechanical calibration using polynomial models.
Option CDA provides characterized data specific to the serial number of the calibration kit to
Designed exclusively for Keysight's vector network analyzers
85050G
Keysight’s 85050G 7 mm data-based mechanical calibration kit calibrates the measurement setups using Keysight’s vector network analyzer for the devices under test with 7 mm connectors. The 85050G uses new data-based models and Option CDA provides better directivity performance than traditional mechanical calibration using polynomial models.
Option CDA provides characterized data specific to the serial number of the calibration kit to:
Designed exclusively for Keysight's vector network analyzers.
85521A
此模組在輕巧型裝置中整合了開路、短路、負載和穿透功能,可輕鬆校驗非插入式裝置。
Keysight 85521A 四合一機械校驗套件模組非常小巧,可提供開路、短路、負載和直通校驗。 該模組體積小、重量輕而且易於操作。 直通校驗讓使用者能夠輕鬆校驗非插入式元件,例如:纜線或配備母頭對母頭接頭的濾波器。 執行直通校驗時,可使用 85521A 直通校驗套件。
N4691D
使用適用於 3.5 mm 連接器的雙埠模組,實現更精準的量測。
Keysight N4691D 微波電子校驗(ECal)模組可快速、輕鬆又準確地對是德科技向量網路分析儀進行校驗。N4691D 是精密的 2 埠 ECal 模組,支援高達 26.5 GHz 的 3.5 mm 連接器。我們備有母頭對母頭、公頭對公頭,或是母頭對公頭等連接器供您選擇。N4691D 隨附塑膠儲放盒,可保護 ECal 模組和配件。
N4691D 選項 0DC 可將校驗頻率範圍擴展至直流,這有利於使用是德科技網路分析儀的增強時域分析特性,進行寬頻裝置建模或時域和信號完整性分析。
此 ECal 模組是校驗向量網路分析儀的理想解決方案。使用電子校驗進行全雙埠校驗的時間和連接次數還不到使用傳統機械校驗套件時的一半。操作人員只需透過 USB 將 ECal 模組連接到向量網路分析儀,接著韌體會進行其他部分的控制,進而減少操作人員出錯的機率。此外,連接器的磨損也降低了,使得測試埠連接器和校驗標準的維修成本隨之降低。
Q11644A
輕鬆校驗網路分析儀的系統誤差;包括用於執行 TRL 校驗的精密空氣傳輸線。
Keysight Q11644A 校驗套件內含精密型機械標準套件,可校驗是德科技網路分析儀的系統誤差。 此校驗套件內含一條精密的空氣傳輸線,可執行直通 - 反射 - 線路(TRL)校驗。這是校驗同軸量測誤差最準確的一種方法。 套件中還包含一張商業校驗證書、嵌入式短路器、一個精密墊片和固定終端。