Choose a country or area to see content specific to your location
O que você está procurando?
3D Interconnect Designer provides a flexible modeling and optimization environment for any advanced interconnect structure, including chiplets, stacked die, packages, and PCBs.
Get faster digital validation for less with a trade-in.
Emulate every part of your data center infrastructure. Emulate Anything. Optimize Everything.
Use 25+ X-Series applications to analyze, demodulate, and troubleshoot signals across wireless, aerospace/defense, EMI, and phase noise.
With extra memory and storage, these enhanced NPBs run Keysight's AI security and performance monitoring software and AI stack.
Achieve fast, accurate board-level testing with robust inline and offline ICT designed for modern manufacturing.
Explore curated support plans, prioritized to keep you innovating at speed.
Pinpoint interference with post-processing spectrum management software in the lab.
Use this selector tool to quickly identify the best power supply for your aerospace and defense ATE requirements.
Explore engineer-authored content and a vast knowledge base with thousands of learning opportunities.
Keysight Learn offers immersive content on topics of interest, including solutions, blogs, events, and more.
Quick access to the most frequent support related self-help tasks.
Additional content to support your product needs.
Explore services to accelerate every step of your innovation journey.
Explore the complete portfolio of Keysight accessories designed to complement and extend your instruments. Use the filters below to quickly find compatible accessories such as modules, cables, adapters, and other system components to configure, expand, and optimize your test system for your specific measurement needs.
No Filter available
No Filter available
The M9341A digital I/O with the 24-bit digital I/O connector and triggering ports provides communication signals between the PXI vector network analyzer (VNA) installed in the same PXI chassis and an external handler.
The M9341A digital I/O with the 24-bit digital I/O connector and triggering ports provides communication signals between the PXI vector network analyzer (VNA) installed in the same PXI chassis and an external handler.
M9341A
The M9341A digital I/O with the 24-bit digital I/O connector and triggering ports provides communication signals between the PXI vector network analyzer (VNA) installed in the same PXI chassis and an external handler.
The M9341A digital I/O with 24-bit digital I/O connector and triggering ports provides communication signals between the PXI vector network analyzer (VNA) installed in the same PXI chassis and an external handler. This allows the PXI VNA, such as the Keysight M937xA and M9485A, to operate in an automated test environment.
The M9341A digital I/O is compatible to the 24-bit digital I/O connector on the rear panel of the Keysight VNA such as the PNA and ENA Series.
Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. This kit is specified from dc to 9 GHz.
Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. This kit is specified from dc to 9 GHz.
85033E
Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. This kit is specified from dc to 9 GHz.
The Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. A torque wrench is also included for proper connection. This kit is specified from dc to 9 GHz.
Options are available to add 3.5 mm female to female, 3.5 mm male to male and 3.5 mm female to male adapters. Other options add four 3.5mm to type-N adapters or four 3.5 mm to 7 mm adapters.
Characterize the systematic errors of network analyzers in the 3.5-mm interface; includes 50 Ω airline for TRL calibration.
Characterize the systematic errors of network analyzers in the 3.5-mm interface; includes 50 Ω airline for TRL calibration.
85052C
Characterize the systematic errors of network analyzers in the 3.5-mm interface; includes 50 Ω airline for TRL calibration.
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
Combines unmatched flexibility of configuration with excellent repeatability, long life, and reliability.
Combines unmatched flexibility of configuration with excellent repeatability, long life, and reliability.
N1810UL
Combines unmatched flexibility of configuration with excellent repeatability, long life, and reliability.
The Keysight N1810UL latching coaxial switch combines unmatched flexibility of configuration with excellent repeatability, long life, and reliability.
For additional information regarding configuration options and performance tradeoffs view the online product overview.
Achieve more precise and accurate measurements with this 2-port module for 3.5-mm connectors.
Achieve more precise and accurate measurements with this 2-port module for 3.5-mm connectors.
N4691D
Achieve more precise and accurate measurements with this 2-port module for 3.5-mm connectors.
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
The N4691D Option 0DC extends the calibration frequency range down to DC, which is beneficial for broadband device modeling or time domain and signal integrity analysis using enhanced time domain-analysis on the Keysight network analyzers.
This ECal module is an ideal solution for calibrating vector network analyzers. Performing a full two-port calibration takes less than half the time and number of connections versus traditional mechanical cal kits. The operator simply connects the ECal module to the vector network analyzer via USB and the firmware controls the rest, thus reducing the chance for operator error. Wear and tear on connectors is reduced as well, lowering repair costs on both the test port connectors and calibration standards.
The E4412A CW power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -70 to +20 dBm (90 dB dynamic range).
The E4412A CW power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -70 to +20 dBm (90 dB dynamic range).
E4412A
The E4412A CW power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -70 to +20 dBm (90 dB dynamic range).
The N1921A wideband power sensor (50MHz to 18GHz) provides peak, peak-to-average ratio, average power, rise/fall time and statistical data of wideband signals.
The N1921A wideband power sensor (50MHz to 18GHz) provides peak, peak-to-average ratio, average power, rise/fall time and statistical data of wideband signals.
N1921A
The N1921A wideband power sensor (50MHz to 18GHz) provides peak, peak-to-average ratio, average power, rise/fall time and statistical data of wideband signals.
The N192xA wideband power sensors are the first to feature internal zero and calibration, integrating a DC reference source and switching circuits directly into the sensor. This innovation eliminates the need for multiple connections to an external calibration source, reducing connector wear, shortening test time, and minimizing measurement uncertainty.
Achieve more precise and accurate measurements with this 2-port module for 2.92-mm connectors.
Achieve more precise and accurate measurements with this 2-port module for 2.92-mm connectors.
N4692D
Achieve more precise and accurate measurements with this 2-port module for 2.92-mm connectors.
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
The N4692D Option 0DC extends the calibration frequency range down to DC, which is beneficial for broadband device modeling or time domain and signal integrity analysis using enhanced time domain-analysis on the Keysight network analyzers.
This ECal module is an ideal solution for calibrating vector network analyzers. Performing a full two-port calibration takes less than half the time and number of connections versus traditional mechanical cal kits. The operator simply connects the ECal module to the vector network analyzer via USB and the firmware controls the rest, thus reducing the chance for operator error. Wear and tear on connectors is reduced as well, lowering repair costs on both the test port connectors and calibration standards.
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
85563A
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
The 85563A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and light weight. All standards in the 85563A are female 2.4 mm.
For more information about calibration kits, please visit Mechanical and Electronic Calibration Kits.
Designed to protect the test set port with a special rugged female connector and a return loss of 23 dB or better
Designed to protect the test set port with a special rugged female connector and a return loss of 23 dB or better
85130G
Designed to protect the test set port with a special rugged female connector and a return loss of 23 dB or better
The Keysight 85130G test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a NMD-2.4 mm (f) to NMD-2.4 mm (m) adapter and a NMD-2.4 mm (f) to PSC-2.4 mm (f) adapter. The frequency range for these adapters is dc to 50 GHz with a return loss of 23 dB or better.
Designed to protect the test set port with a special rugged female connector and a return loss of 26 dB or better
Designed to protect the test set port with a special rugged female connector and a return loss of 26 dB or better
85130F
Designed to protect the test set port with a special rugged female connector and a return loss of 26 dB or better
The Keysight 85130F test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 2.4 mm to PSC-3.5 mm male adapter and a 2.4 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 26 dB or better.
Designed to protect the test set port when with a special rugged female connector and a return loss of 28 dB or better
Designed to protect the test set port when with a special rugged female connector and a return loss of 28 dB or better
85130D
Designed to protect the test set port when with a special rugged female connector and a return loss of 28 dB or better
The Keysight 85130D test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 3.5 mm to PSC-3.5 mm male adapter and a 3.5 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 28 dB or better.
For more information about 3.5 mm cables and adapters, please visit Cables for Network Analyzers with 3.5 mm Test Ports.