3D Interconnect Designer provides a flexible modeling and optimization environment for any advanced interconnect structure, including chiplets, stacked die, packages, and PCBs.
Get faster digital validation for less with a trade-in.
Emulate every part of your data center infrastructure. Emulate Anything. Optimize Everything.
With extra memory and storage, these enhanced NPBs run Keysight's AI security and performance monitoring software and AI stack.
Achieve fast, accurate board-level testing with robust inline and offline ICT designed for modern manufacturing.
Explore curated support plans, prioritized to keep you innovating at speed.
Achieve 200+ Gbaud multi-level modulated signals with high-speed AWGs for digital and optical standards.
Pinpoint interference with post-processing spectrum management software in the lab.
Use this selector tool to quickly identify the best power supply for your aerospace and defense ATE requirements.
Authoritative application notes, data sheets, reference designs, and test procedures to accelerate design and validation decisions.
Hands‑on bootcamps that teach system design, test methods, and production workflows engineers can apply immediately.
Success Stories
Quick access to support related self-help tasks.
Additional content to support your product needs.
Explore services to accelerate every step of your innovation journey.
Explore the complete portfolio of Keysight accessories designed to complement and extend your instruments. Use the filters below to quickly find compatible accessories such as modules, cables, adapters, and other system components to configure, expand, and optimize your test system for your specific measurement needs.
No Filter available
Connect test fixtures with a 7 mm connector to the network analyzer’s test ports (type-N)
Connect test fixtures with a 7 mm connector to the network analyzer’s test ports (type-N)
16201A
Connect test fixtures with a 7 mm connector to the network analyzer’s test ports (type-N)
The 16201A terminal adapter is provided for the connection between the network analyzer’s test ports (type-N) and test fixtures with a 7 mm connector. Impedance analysis using the reflection method is supported with the E5061B ENA LF-RF Network Analyzer (Option 3L3/3L4/3L5) and impedance analysis software (Option 005).
Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. This kit is specified from dc to 9 GHz.
Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. This kit is specified from dc to 9 GHz.
85033E
Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. This kit is specified from dc to 9 GHz.
The Keysight 85033E calibration kit contains precision 3.5mm standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. A torque wrench is also included for proper connection. This kit is specified from dc to 9 GHz.
Options are available to add 3.5 mm female to female, 3.5 mm male to male and 3.5 mm female to male adapters. Other options add four 3.5mm to type-N adapters or four 3.5 mm to 7 mm adapters.
Complete high-frequency probing without adversely loading the circuit under test
Complete high-frequency probing without adversely loading the circuit under test
85024A
Complete high-frequency probing without adversely loading the circuit under test
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.
For more information about RF Probes, please visit Keysight RF Probes.
16200B can operate with high frequency LCR meters and impedance analyzers that can supply a bias current across the device of up to 5 Adc with 7 mm port.
16200B can operate with high frequency LCR meters and impedance analyzers that can supply a bias current across the device of up to 5 Adc with 7 mm port.
16200B
16200B can operate with high frequency LCR meters and impedance analyzers that can supply a bias current across the device of up to 5 Adc with 7 mm port.
The 16200B test fixture is designed to operate with high frequency LCR meters and impedance analyzers. It allows you to supply a bias current across the device of up to 5 Adc through a 7 mm port by using an external DC current source.
Designed to protect the test set port with a special rugged female connector and a return loss of 23 dB or better
Designed to protect the test set port with a special rugged female connector and a return loss of 23 dB or better
85130G
Designed to protect the test set port with a special rugged female connector and a return loss of 23 dB or better
The Keysight 85130G test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a NMD-2.4 mm (f) to NMD-2.4 mm (m) adapter and a NMD-2.4 mm (f) to PSC-2.4 mm (f) adapter. The frequency range for these adapters is dc to 50 GHz with a return loss of 23 dB or better.
Designed to protect the test set port with a special rugged female connector and a return loss of 26 dB or better
Designed to protect the test set port with a special rugged female connector and a return loss of 26 dB or better
85130F
Designed to protect the test set port with a special rugged female connector and a return loss of 26 dB or better
The Keysight 85130F test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector designed for connecting to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. The set contains a 2.4 mm to PSC-3.5 mm male adapter and a 2.4 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 26 dB or better.
Designed to protect the test set port when with a special rugged female connector and a return loss of 28 dB or better
Designed to protect the test set port when with a special rugged female connector and a return loss of 28 dB or better
85130D
Designed to protect the test set port when with a special rugged female connector and a return loss of 28 dB or better
The Keysight 85130D test port adapter protects the test set port from being directly connected to the device under test. These adapters have a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a 3.5 mm to PSC-3.5 mm male adapter and a 3.5 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 28 dB or better.
Characterize the systematic errors of network analyzers in the 1.85-mm interface; includes connector gauges
Characterize the systematic errors of network analyzers in the 1.85-mm interface; includes connector gauges
85058B
Characterize the systematic errors of network analyzers in the 1.85-mm interface; includes connector gauges
The Keysight 85058B standard mechanical calibration kit contains precision standard devices to characterize the systematic errors of the Keysight network analyzers in the 1.85 mm interface. This kit also contains adapters to change the gender of the test port, connector gauges for verifying and maintaining the connector interface, and a torque wrench for proper connection.
Characterize the systematic errors of network analyzers in the 3.5-mm interface; includes 50 Ω airline for TRL calibration.
Characterize the systematic errors of network analyzers in the 3.5-mm interface; includes 50 Ω airline for TRL calibration.
85052C
Characterize the systematic errors of network analyzers in the 3.5-mm interface; includes 50 Ω airline for TRL calibration.
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
Provides high-input impedance and can be used with a network and spectrum analyzer for circuit signal analysis.
Provides high-input impedance and can be used with a network and spectrum analyzer for circuit signal analysis.
41800A
Provides high-input impedance and can be used with a network and spectrum analyzer for circuit signal analysis.
The Keysight 41800A Active Probe provides high input impedance from 5 Hz to 500 MHz. The Keysight 41800A is a valuable tool when used with a network and spectrum analyzer for circuit signal analysis.
For more information about RF Probes, please visit Keysight RF Probes.
Suppress low frequency signals that can damage expensive measuring equipment or affect measurement accuracy.
Suppress low frequency signals that can damage expensive measuring equipment or affect measurement accuracy.
11742A
Suppress low frequency signals that can damage expensive measuring equipment or affect measurement accuracy.
The Keysight 11742A blocking capacitor blocks dc signals below 45 MHz and passes signals up to 26.5 GHz. Ideal for use with high-frequency oscilloscopes or in biased microwave circuits, the Keysight 11742A will suppress low frequency signals that can damage expensive measuring equipment or affect the accuracy of your RF and microwave measurements.
85032F Standard Mechanical Calibration Kit, DC to 9 GHz.
85032F Standard Mechanical Calibration Kit, DC to 9 GHz.
85032F
85032F Standard Mechanical Calibration Kit, DC to 9 GHz.
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
Options are available to add type-N female to female, type-N male to male and type-N female to male adapters. Another option also exists to add four type-N to 7 mm adapters.