N7878A PXI Multiport Vector Network Analyzer Calibration Application
是德建議使用最新的版本,其中包括最新的漏洞修復與安全覆蓋
| 發佈日期 | 版本 | 版本說明 |
|---|---|---|
| 2017-12-01 | E.02.00 | Added support for the UUT models M9377A, M9378A and M9378B. Added support for 8496G Option H52 step attenuator. Added support for E9304A Option H19 power sensor. Added "Store Cal Info to Module" test to store the calibration date into the module. Fixed the error encountered when running tests using the N1912A power meter. Fixed the connection check error in the Dynamic Accuracy - 1MHz test. Removed the reflection size and reflection angle calibration data requirement for 8496G and 8496H step attenuators, thus default value (zero) entry is allowed. Updated the step attenuator's connection prompt and diagram to define the port used for testing and for entering calibration data in TME. Enhanced M9376A's Receiver Compression test for better source accuracy. Enhanced the installation package to support multi-language installations. |
| 發佈日期 | 版本 |
|---|---|
| 2017-12-01 | E.02.00 |
| Version Description |
|---|
| Added support for the UUT models M9377A, M9378A and M9378B. Added support for 8496G Option H52 step attenuator. Added support for E9304A Option H19 power sensor. Added "Store Cal Info to Module" test to store the calibration date into the module. Fixed the error encountered when running tests using the N1912A power meter. Fixed the connection check error in the Dynamic Accuracy - 1MHz test. Removed the reflection size and reflection angle calibration data requirement for 8496G and 8496H step attenuators, thus default value (zero) entry is allowed. Updated the step attenuator's connection prompt and diagram to define the port used for testing and for entering calibration data in TME. Enhanced M9376A's Receiver Compression test for better source accuracy. Enhanced the installation package to support multi-language installations. |
如何下載
- Close all applications.
- Download application .exe file to the PC desktop.
如何安裝
- Download the Setup.exe file to the PC desktop.
- Run Setup.exe as follows: Right-click the Setup.exe file and select “Run as Administrator” to start the installation.
- Follow the instructions on the screen to install the Test Management Environment.
Important Note: After the initial N7800A TME installation, be sure to launch the application in Normal mode. Do not launch in Administrator mode. Administrator mode is only used for the initial installation of the N7800A TME application.
授權
- Requires a License
To obtain a key contact your local Keysight Technologies Sales Representative.
支援文件
Installs on: PC
作業系統
- Windows 10
Minimum Requirements to Run TME N78xxA Application Software:
- TME revision E.03.91 or higher
- Check individual N78xxA Application’s ReadMe files for specific requirements
參加條件
支援的儀器
- M9340A, M9376A, M9377A, M9378A, M9378B
如何下載
- Close all applications.
- Download application .exe file to the PC desktop.
如何安裝
- Download the Setup.exe file to the PC desktop.
- Run Setup.exe as follows: Right-click the Setup.exe file and select “Run as Administrator” to start the installation.
- Follow the instructions on the screen to install the Test Management Environment.
Important Note: After the initial N7800A TME installation, be sure to launch the application in Normal mode. Do not launch in Administrator mode. Administrator mode is only used for the initial installation of the N7800A TME application.
授權
- Requires a License
To obtain a key contact your local Keysight Technologies Sales Representative.
支援文件
Installs on: PC
作業系統
- Windows 10
Minimum Requirements to Run TME N78xxA Application Software:
- TME revision E.03.91 or higher
- Check individual N78xxA Application’s ReadMe files for specific requirements
參加條件
支援的儀器
- M9340A, M9376A, M9377A, M9378A, M9378B
SHOW MORE