Keysight는 가능한 최신 버전을 사용하는 것을 권장하며, 최신 버전에는 현재 사용 가능한 가장 최신 버그 수정 및 보안 패치가 포함되어 있습니다.
릴리스 날짜 버젼 버전 설명
2026-11-20 2026 Update 2 Build A.26.02.758
릴리스 날짜 버젼
2026-11-20 2026 Update 2
Version Description
Build A.26.02.758

This software is designed to run on:

  • Keysight Infiniium XR8 real-time oscilloscopes.
  • Personal computers with the Windows 11 operating system.

New Features and Enhancements

  • New protocol decodes:
    • D9310MPMP: MIPI M-PHY UFS v5
    • D9310USBP: USB v3.2 Gen 1-2
    • D9310PCIP: PCIe Gen 1-7
    • D9310MPMP: MIPI M-PHY UniPro v3.0
    • D9310USBP: USB4 Tunneling USB3
    • D9310USBP: USB4 Tunneling PCIe Gen 3-5
    • D9310MCDP: MIPI DPHY v2.1 CSI-2 v2.1
    • D9310MCDP: MIPI DPHY v2.1 DSI-2 v1.1
  • Protocol demos have been added.
  • Hardware-based digital down conversion (DDC):
    • Standard: Hardware Accelerated DDC for XR8, 200MHz BW
    • XR804KA-602: Hardware Accelerated DDC for XR8, 3.2 GHz BW
    • XR804KA-606: Hardware Accelerated DDC for XR8, 6.4 GHz BW
  • Frequency extension window:
    • XR804KA-610: 10 GHz Frequency extension, movable bandwidth window
    • XR804KA-620: 20 GHz Frequency extension, movable bandwidth window
  • These probes are now supported:
    • N7004A 33GHz Optical-to-Electrical Converter
    • N7005A 60 GHz Optical-to-Electrical Converter
    • N7024A 6GHz Power Rail Probe
  • Cable and probe calibrated de-embedding has been added.
  • You can now use XR3 Low Profile oscilloscopes as a high impedance probing solution for the XR8 oscilloscopes (MultiScope instrument configuration).
  • Offline installation (on a PC) no longer requires MATLAB.
  • You can now save/load multiple waveforms to/from a single HDF5 or BIN format file.
  • You can now save jitter graph and histogram data through the documentation wizard or SCPI.
  • With XR8 oscilloscope acquisition averaging, the minimum number of averages increased to 4 and the maximum number of averages increased to 2,000,000. You must now select an even number of averages.
  • Trigger status (Arm'd, Trig'd, Auto, Stop'd) is now shown in the trigger badge.
  • You can now reset the sequential hardware trigger using a pattern condition.
  • Clock Recovery now offers channel Automatic Clock Skew.
  • Grid Lines, Axis Labels, and Connect Points display setup graticule options do not reset with Default Setup, only with Factory Default.
  • When running on XR8 oscilloscopes, the Use On-Screen Keyboard preference (in the Display Setup dialog box Appearance tab) is selected by default.
  • Enhanced Multipurpose 'Save' action to optionally save both screenshots and waveforms.
  • These new functions have been added:
    • Envelope
    • CTLE/FFE/DFE Co-optimization
      • Requires license D9320ASIA
  • Automatic taps for Linear Square Error DFE for PAM4 signal has been enabled:
    • Requires licenses D9320ASIA and D9320PAMA
  • These new measurements have been added:
    • Area
    • Clock Unit Interval
  • The 'Hide' option for individual markers and annotations has been replaced with an on/off control per instance.
  • Global regions are now grouped by X-Units type.
  • You can now create a gating region from within the region dialog box.
  • PAM eye measurement settings are now per signal. PAM eye and level measurements now have per-measurement amplitude unit settings.
  • PAM-3/6/8 Jitter and Noise measurements have been added:
    • Requires license D9320ASIA
  • Added Gaussian shape to PAM4 analysis.
  • The Y-axis on Jitter spectrum graphs no longer autoscale.
  • Measurement Limit Test Search and Mark has been added.
  • The Apps menu item (under Tools) is now always visible and contains a link to the help topic that has links for downloading compliance apps.
  • You can now save SPCI Recorder output as a Python script.
  • Several SCPI commands that have boolean SCPI parameters now correctly take 0 and 1 as well as ON and OFF. The query form now returns 0 and 1 instead of ON and OFF.
  • You can now use indefinite-length block transfers from/to files when data is larger than
    1GB:
    • DISK:FILE:IBLock:READ
    • DISK:FILE:IBLock:WRITE
  • Added Waveform Count to measurement statistics:
    • :MEASure:RESults?
  • Can now query all occurrences of waveform measurements:
    • :MEASure:LIST:ITEM{N}:RESults:DOUBle:DATA?
    • :MEASure:LIST:ITEM{N}:RESults:DOUBle:XDATA?
  • Added Jitter and Noise query all results:
    • :MEASure:JITTer<n>:JITTer:ALL?
    • :MEASure:JITTer<n>:NOISe:ALL?
  • You can now query PAM Jitter results in bulk via SCPI:
    • :MEASure:PJITter{0}:TABLe:DATA:{J3U, J4U, J5U, J6U, J8U, JRMS, EOJ}?
    • :MEASure:PJITter{0}:DDIRac:DATA:{J3U, J4U, J5U, J6U, JRMS, TRJ, TUDJ, TUTJ, RJComp}?

Fixes

  • Multi-waveform BIN format save (DIFF1 and DIFF3) now returns consistent record lengths.
  • The minimum bandwidth allowed for channel bandwidth filters and bandwidth filter functions has been changed.
  • Clock skew for CDR is now per-signal. The global clock skew has been removed. Auto clock skew is applied by default for each channel. The :CRECovery:CSKew SCPI command has been removed.
  • Removed dialog box sizing capability to prevent offscreen dialog boxes.
  • User Defined Function X/Y units can be set only on first pass or by user input, and no longer dynamically.
  • Improved auto thresholds, auto set top-base button, auto set manual thresholds.
  • The Copy From thresholds button now copies all threshold settings.
  • The jitter histogram algorithm has changed slightly for more accurate results. This will cause a small change in measured jitter values in tailfit mode.

 

다운로드 방법

  • Click the download button and save the file to a temporary directory on your oscilloscope or PC.

설치 방법

  • On the oscilloscope or PC, right-click the downloaded file and choose "Run as administrator" (or some other option for running with elevated privileges); then, follow the on-screen installation instructions.

라이센스

  • Does Not Require a License

Installs on: XR8 real-time oscilloscope or PC

운영 체제

  • Windows 11

선결 조건

  • Information Not Available

지원되는 계측기

  • XR8 Real-Time Oscilloscopes

This software is designed to run on:

  • Keysight Infiniium XR8 real-time oscilloscopes.
  • Personal computers with the Windows 11 operating system.

Fixes

  • Fixed probe connectivity issues.

 

다운로드 방법

  • Click the download button and save the file to a temporary directory on your oscilloscope or PC.

설치 방법

  • On the oscilloscope or PC, right-click the downloaded file and choose "Run as administrator" (or some other option for running with elevated privileges); then, follow the on-screen installation instructions.

라이센스

  • Does Not Require a License

Installs on: XR8 real-time oscilloscope or PC

운영 체제

  • Windows 11

선결 조건

  • Information Not Available

지원되는 계측기

  • XR8 Real-Time Oscilloscopes

This software is designed to run on:

  • Keysight Infiniium XR8 real-time oscilloscopes.
  • Personal computers with the Windows 11 operating system.

Enhancements

  • Added :CHANnel<n>:PROBe:CORRection:SIMPedance SCPI command.

 

다운로드 방법

  • Click the download button and save the file to a temporary directory on your oscilloscope or PC.

설치 방법

  • On the oscilloscope or PC, right-click the downloaded file and choose "Run as administrator" (or some other option for running with elevated privileges); then, follow the on-screen installation instructions.

라이센스

  • Does Not Require a License

Installs on: XR8 real-time oscilloscope or PC

운영 체제

  • Windows 11

선결 조건

  • Information Not Available

지원되는 계측기

  • XR8 Real-Time Oscilloscopes