Infiniium 2026 Real-Time Oscilloscope Analysis Software
Keysight recommends using the most current version, which includes the most up-to-date bug fixes and security patches available.
| Release Date | Version | Version Description |
|---|---|---|
| 2026-11-20 | 2026 Update 2 | Build A.26.02.758 |
| Release Date | Version |
|---|---|
| 2026-11-20 | 2026 Update 2 |
| Version Description |
|---|
| Build A.26.02.758 |
This software is designed to run on:
- Keysight Infiniium XR8 real-time oscilloscopes.
- Personal computers with the Windows 11 operating system.
New Features and Enhancements
- New protocol decodes:
- D9310MPMP: MIPI M-PHY UFS v5
- D9310USBP: USB v3.2 Gen 1-2
- D9310PCIP: PCIe Gen 1-7
- D9310MPMP: MIPI M-PHY UniPro v3.0
- D9310USBP: USB4 Tunneling USB3
- D9310USBP: USB4 Tunneling PCIe Gen 3-5
- D9310MCDP: MIPI DPHY v2.1 CSI-2 v2.1
- D9310MCDP: MIPI DPHY v2.1 DSI-2 v1.1
- Protocol demos have been added.
- Hardware-based digital down conversion (DDC):
- Standard: Hardware Accelerated DDC for XR8, 200MHz BW
- XR804KA-602: Hardware Accelerated DDC for XR8, 3.2 GHz BW
- XR804KA-606: Hardware Accelerated DDC for XR8, 6.4 GHz BW
- Frequency extension window:
- XR804KA-610: 10 GHz Frequency extension, movable bandwidth window
- XR804KA-620: 20 GHz Frequency extension, movable bandwidth window
- These probes are now supported:
- N7004A 33GHz Optical-to-Electrical Converter
- N7005A 60 GHz Optical-to-Electrical Converter
- N7024A 6GHz Power Rail Probe
- Cable and probe calibrated de-embedding has been added.
- You can now use XR3 Low Profile oscilloscopes as a high impedance probing solution for the XR8 oscilloscopes (MultiScope instrument configuration).
- Offline installation (on a PC) no longer requires MATLAB.
- You can now save/load multiple waveforms to/from a single HDF5 or BIN format file.
- You can now save jitter graph and histogram data through the documentation wizard or SCPI.
- With XR8 oscilloscope acquisition averaging, the minimum number of averages increased to 4 and the maximum number of averages increased to 2,000,000. You must now select an even number of averages.
- Trigger status (Arm'd, Trig'd, Auto, Stop'd) is now shown in the trigger badge.
- You can now reset the sequential hardware trigger using a pattern condition.
- Clock Recovery now offers channel Automatic Clock Skew.
- Grid Lines, Axis Labels, and Connect Points display setup graticule options do not reset with Default Setup, only with Factory Default.
- When running on XR8 oscilloscopes, the Use On-Screen Keyboard preference (in the Display Setup dialog box Appearance tab) is selected by default.
- Enhanced Multipurpose 'Save' action to optionally save both screenshots and waveforms.
- These new functions have been added:
- Envelope
- CTLE/FFE/DFE Co-optimization
- Requires license D9320ASIA
- Automatic taps for Linear Square Error DFE for PAM4 signal has been enabled:
- Requires licenses D9320ASIA and D9320PAMA
- These new measurements have been added:
- Area
- Clock Unit Interval
- The 'Hide' option for individual markers and annotations has been replaced with an on/off control per instance.
- Global regions are now grouped by X-Units type.
- You can now create a gating region from within the region dialog box.
- PAM eye measurement settings are now per signal. PAM eye and level measurements now have per-measurement amplitude unit settings.
- PAM-3/6/8 Jitter and Noise measurements have been added:
- Requires license D9320ASIA
- Added Gaussian shape to PAM4 analysis.
- The Y-axis on Jitter spectrum graphs no longer autoscale.
- Measurement Limit Test Search and Mark has been added.
- The Apps menu item (under Tools) is now always visible and contains a link to the help topic that has links for downloading compliance apps.
- You can now save SPCI Recorder output as a Python script.
- Several SCPI commands that have boolean SCPI parameters now correctly take 0 and 1 as well as ON and OFF. The query form now returns 0 and 1 instead of ON and OFF.
- You can now use indefinite-length block transfers from/to files when data is larger than
1GB:- DISK:FILE:IBLock:READ
- DISK:FILE:IBLock:WRITE
- Added Waveform Count to measurement statistics:
- :MEASure:RESults?
- Can now query all occurrences of waveform measurements:
- :MEASure:LIST:ITEM{N}:RESults:DOUBle:DATA?
- :MEASure:LIST:ITEM{N}:RESults:DOUBle:XDATA?
- Added Jitter and Noise query all results:
- :MEASure:JITTer<n>:JITTer:ALL?
- :MEASure:JITTer<n>:NOISe:ALL?
- You can now query PAM Jitter results in bulk via SCPI:
- :MEASure:PJITter{0}:TABLe:DATA:{J3U, J4U, J5U, J6U, J8U, JRMS, EOJ}?
- :MEASure:PJITter{0}:DDIRac:DATA:{J3U, J4U, J5U, J6U, JRMS, TRJ, TUDJ, TUTJ, RJComp}?
Fixes
- Multi-waveform BIN format save (DIFF1 and DIFF3) now returns consistent record lengths.
- The minimum bandwidth allowed for channel bandwidth filters and bandwidth filter functions has been changed.
- Clock skew for CDR is now per-signal. The global clock skew has been removed. Auto clock skew is applied by default for each channel. The :CRECovery:CSKew SCPI command has been removed.
- Removed dialog box sizing capability to prevent offscreen dialog boxes.
- User Defined Function X/Y units can be set only on first pass or by user input, and no longer dynamically.
- Improved auto thresholds, auto set top-base button, auto set manual thresholds.
- The Copy From thresholds button now copies all threshold settings.
- The jitter histogram algorithm has changed slightly for more accurate results. This will cause a small change in measured jitter values in tailfit mode.
How to Download
Click the download button and save the file to a temporary directory on your oscilloscope or PC.
How to Install
- On the oscilloscope or PC, right-click the downloaded file and choose "Run as administrator" (or some other option for running with elevated privileges); then, follow the on-screen installation instructions.
Licensing
- Does Not Require a License
Supporting Documentation
Installs on: XR8 real-time oscilloscope or PC
Operating System
- Windows 11
Prerequisites
- Information Not Available
Supported Instruments
- XR8 Real-Time Oscilloscopes
This software is designed to run on:
- Keysight Infiniium XR8 real-time oscilloscopes.
- Personal computers with the Windows 11 operating system.
Fixes
- Fixed probe connectivity issues.
How to Download
Click the download button and save the file to a temporary directory on your oscilloscope or PC.
How to Install
- On the oscilloscope or PC, right-click the downloaded file and choose "Run as administrator" (or some other option for running with elevated privileges); then, follow the on-screen installation instructions.
Licensing
- Does Not Require a License
Supporting Documentation
Installs on: XR8 real-time oscilloscope or PC
Operating System
- Windows 11
Prerequisites
- Information Not Available
Supported Instruments
- XR8 Real-Time Oscilloscopes
This software is designed to run on:
- Keysight Infiniium XR8 real-time oscilloscopes.
- Personal computers with the Windows 11 operating system.
Enhancements
- Added :CHANnel<n>:PROBe:CORRection:SIMPedance SCPI command.
How to Download
Click the download button and save the file to a temporary directory on your oscilloscope or PC.
How to Install
- On the oscilloscope or PC, right-click the downloaded file and choose "Run as administrator" (or some other option for running with elevated privileges); then, follow the on-screen installation instructions.
Licensing
- Does Not Require a License
Supporting Documentation
Installs on: XR8 real-time oscilloscope or PC
Operating System
- Windows 11
Prerequisites
- Information Not Available
Supported Instruments
- XR8 Real-Time Oscilloscopes
SHOW MORE