Column Control DTX

FieldFox Handheld Analyzers 4/6.5/9/14/18/26.5/32/44/50 GHz

데이터 시트

Definitions

Specification (spec)

Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Specifications are warranted performance. FieldFox must be within its calibration cycle. No warm-up required for the spectrum analyzer specifications listed on pages 25 through 50.

Typical

Describes additional product performance information not covered by the product warranty. It is performance beyond specifications that 80% of the units exhibit with a 90% confidence level over the temperature range 23 ± 5°C, unless otherwise noted. Typical performance does not include measurement uncertainty. FieldFox must be within its calibration cycle.

Nominal

A general, descriptive term or design parameter. It is not tested, and not covered by the product warranty. FieldFox must be within its calibration cycle.

Test port output specifications

High power in N991xA and N992xA refers to the target output power level of the analyzer when the Power Setting is set to High. As an example, if you have a frequency sweep from 3 to 6.5 GHz, the analyzer will achieve the power level of -1 dBm across the band.

Low power level for N991xA and N992xA analyzers is a flat -45 dBm across the whole frequency band and is the output of the analyzer when the Power Setting is set to Low.

High power in the N995xA refers to the target output power level of the analyzer when the Power Setting is set to High. As an example, if you have a frequency sweep from 39 to 46 GHz, the analyzer will achieve the power level of -2 dBm across the band.

Low power level for N995xA analyzers is the lowest power level that can be set and is the output of the analyzer when the Power Setting is set to Low.

Max leveled power in the N995xA refers to the maximum leveled (flattened) power that can be achieved across the designated frequency range. For example, if you have a frequency sweep from 32 to 44 GHz and set up the analyzer to measure all four S-parameters, needing both ports 1 and 2, the maximum power the analyzer can be set to is -6 dBm.

×

판매 문의 부탁드립니다.

선호하는 연락방법을 선택해 주십시오. *필수입력항목
Preferred method of communication? 이메일 변경하기
Preferred method of communication?

체크 박스를 클릭하시면 이메일, 전화 및 문자 광고성 정보 수신동의를 의미합니다. 참고 : 이미 수신 동의를 한 경우 광고성 정보를 계속 받을 수 있으며, 만약 수신 거부를 원하는 경우 https://www.keysight.com/key/privacy에서 신청할 수 있습니다.
[키사이트 개인정보 수집 및 이용]

  1. 개인정보 수집 및 이용 동의
  2. 키사이트 파트너 업무 위탁 동의
  3. 키사이트 해외 본사 및 지사 제공 동의
양식을 작성하여 제출하시면 개인정보 수집 및 이용에 동의한 것으로 간주합니다. 보다 자세한 내용은 개인정보보호정책을 참조하시기 바랍니다.

감사합니다!

A sales representative will contact you soon.

Column Control DTX