根據需要更新的元件類型,更新可能需要 60 分鐘完成。 在更新過程中,安裝在機箱中的儀器模組取消啟動 ATCA 服務狀態,並且可以停用,以便降低功耗。 機箱風扇速度可能在更新過程中發生變化。 更新結束後,藉由開啟和關閉機箱電源以完成安裝。

是德建議使用最新的版本,其中包括最新的漏洞修復與安全覆蓋
發佈日期 版本 版本說明
2024-02-16 1.4.0 and 2.2.0 See below. Version 1.4.0 is to be used with ESM M9505-00132, M9505-00232 or older only. Version 2.2.0 is to be used with ESM M9505-00133, M9505-00233 or greater only. Download button is removed due to unresolved fan issue. Update to latest FW version instead.
發佈日期 版本
2024-02-16 1.4.0 and 2.2.0
版本說明
See below. Version 1.4.0 is to be used with ESM M9505-00132, M9505-00232 or older only. Version 2.2.0 is to be used with ESM M9505-00133, M9505-00233 or greater only. Download button is removed due to unresolved fan issue. Update to latest FW version instead.

 

Chassis firmware 1.4.0 contains:

  • For use with ESM M9505-00132, M9505-00232, or older only. DO NOT upgrade to this FW version if you are using ESM M9505-00133, M9505-00233 or greater.
  • Support M9502-00019 and M9505-00019 fan assemblies.
  • Improve fan algorithm to limit fan speed in high CPU usage applications.

 

Chassis firmware 2.2.0 contains:

  • For use with ESM M9505-00133, M9505-00233 or greater only. DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.
  • Support M9502-00019 and M9505-00019 fan assemblies.
  • Improve fan algorithm to limit fan speed in high CPU usage applications.
  • Add delay feature for PCIe Upstream Connection.

 

如何下載

  • Click the download button and save the file to your PC

授權

  • Does Not Require a License

Installs on: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • Version 1.4.0: For use with ESM M9505-00132, M9505-00232, or older only. DO NOT upgrade to this FW version if you are using ESM M9505-00133, M9505-00233 or greater. 
  • Version 2.2.0: For use with ESM M9505-00133, M9505-00233 or greater only. DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.

支援的儀器

  • M9502A, M9505A

 

Chassis firmware 1.3.46 contains:

  • For use with ESM M9505-00132, M9505-00232, or older only. DO NOT upgrade to this FW version if you are using ESM M9505-00133, M9505-00233 or greater.
  • Resolve chassis FRU issue with checksum error during firmware bootup showing behaviors of ESM status LED always flashing green and not enumerating installed modules.
  • Firmware update to 1.3.46 or later is recommended if the ESM is moved to a different chassis.

 

Chassis firmware 2.1.6 contains:

  • For use with ESM M9505-00133, M9505-00233 or greater only. DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.
  • Resolve chassis FRU issue causes modules unable to enumerate when using with USB ESM.
  • Resolve unable to set fan speed issue when using with non_USB ESM

 

 

 

如何下載

  • Click the download button and save the file to your PC

授權

  • Does Not Require a License

Installs on: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • Version 1.3.46: For use with ESM M9505-00132, M9505-00232, or older only. DO NOT upgrade to this FW version if you are using ESM M9505-00133, M9505-00233 or greater. 
  • Version 2.1.6: For use with ESM M9505-00133, M9505-00233 or greater only. DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.

支援的儀器

  • M9502A, M9505A

Chassis firmware 1.3.46 contains:

  • For use with ESM M9505-00132, M9505-00232, or older only. DO NOT upgrade to this FW version if you are using ESM M9505-00133, M9505-00233 or greater.
  • Resolve chassis FRU issue with checksum error during firmware bootup showing behaviors of ESM status LED always flashing green and not enumerating installed modules.
  • Firmware update to 1.3.46 or later is recommended if the ESM is moved to a different chassis.

 

Chassis firmware 2.1.5 contains:

  • For use with ESM M9505-00133, M9505-00233 or greater only. DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.
  • Allow ESM M9505-00133, M9505-00233 or greater to work with chassis serial number TW61130000 or below.
  • Resolve chassis FRU issue with checksum error during firmware bootup showing behaviors of ESM status LED always flashing green and not enumerating installed modules.
  • Firmware update to 2.1.5 or later is recommended if the ESM is moved to a different chassis.

 

 

如何下載

  • Click the download button and save the file to your PC

授權

  • Does Not Require a License

Installs on: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • Version 1.3.46: For use with ESM M9505-00132, M9505-00232, or older only. DO NOT upgrade to this FW version if you are using ESM M9505-00133, M9505-00233 or greater. 
  • Version 2.1.5: For use with ESM M9505-00133, M9505-00233 or greater only. DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.

支援的儀器

  • M9502A, M9505A

Chassis firmware 2.1.4 contains:
 

  • Initial release to support newer version of ESMs used together with chassis serial number TW61130001 or greater. This FW can only be used with ESM M9505-00133, M9505-00233, or greater.  DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.
  • Chassis serial number TW61130000 or below with ESM M9505-00132, M9505-00232, or older should only use FW version 1.3.45.  This FW can only be used with ESM M9505-00133, M9505-00233, or greater.  DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232, or older.
  • Repair issue with hotplug of the USB cable for ESM M9505-00233 or greater.
  • Add new "Publish Address" ipmi command for ESM M9505-00233 or greater. This allows the DDS modules such as U4421A and U4431A to work in chassis with serial number TW61130001 or greater.

授權

  • Does Not Require a License

Installs on: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • For use with chassis serial number TW61130001 or greater and with ESM M9505-00133, M9505-00233 or greater only.  DO NOT upgrade to this FW version if you are using ESM M9505-00132, M9505-00232 or older.

支援的儀器

  • M9502A, M9505A

Chassis firmware 1.3.45 will:
 

  • Rebrand the Chassis Web Interface from “Agilent” to “Keysight”.
  • Repair Health tab on M950xA Web Interface showed incorrect values at Sensor readings.

如何下載

  • Click the download button and save the file to your PC

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • 無相關資訊

支援的儀器

  • M9502A, M9505A

Chassis firmware 1.3.44 will:
 

  • Update the shelf manager to firmware 1.44.
  • Repair an intermittent issue where the chassis is unable to communicate with modules after a boot up if this firmware is combined with chassis drivers 1.4.4.1 or later. This will support obtaining chassis IP address through PCIe switch register instead of using LxiMdnsResponder to resolve the issue.

如何下載

  • Click the download button and save the file to your PC

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • 無相關資訊

支援的儀器

  • M9502A, M9505A

Fixed 3 problems that caused:

  1. embedded controller M9537A to fail to detect some AXIe modules.
  2. embedded controller M9037A to fail to establish a PCIe link to the M9502A/M9505A when using some Y1202A PCIe cables.
  3. the minimum fan level to not be enforced during startup after the dynamic minimum fan level was set in the previous session.
     

如何下載

  • Click the download button and save the file to your PC

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP
  • Windows 8.1
  • Windows 10

參加條件

  • No specific prerequisites

支援的儀器

  • M9502A, M9505A

如何下載

  • Click the download button and save the file to your PC

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP

參加條件

  • 無相關資訊

支援的儀器

  • M9502A, M9505A

如何下載

  • 無相關資訊

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP

參加條件

  • 無相關資訊

支援的儀器

  • M9502A, M9505A

如何下載

  • 無相關資訊

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP

參加條件

  • 無相關資訊

支援的儀器

  • M9502A, M9505A

如何下載

  1. Click Download button
  2. Save .zip file to host computer (c:/tmp)
  3. Unzip the package to your PC

如何安裝

  • Refer to Firmware Update Guide (included in .zip file)

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP

參加條件

  • To upgrade the AXIe chassis firmware, you must have Agilent IO Libraries installed on the host PC. If it is not already installed, you can download it here: https://www.keysight.com/find/iosuite

支援的儀器

  • M9502A, M9505A

如何下載

  1. Click Download button
  2. Save .zip file to host computer (c:/tmp)
  3. Unzip the package to your PC

如何安裝

  • Refer to Firmware Update Guide (included in .zip file)

授權

  • 不需要授權

安裝於: Instrument

作業系統

  • Windows 7
  • Windows XP

參加條件

  • To upgrade the AXIe chassis firmware, you must have Agilent IO Libraries installed on the host PC. If it is not already installed, you can download it here: https://www.keysight.com/find/iosuite

支援的儀器

  • M9502A, M9505A
SHOW MORE