Column Control DTX

Use the Right Vector Network Analyzer for the Job

Product Fact Sheets

Use the Right Vector Network Analyzer for the Job

 

Keysight E5071C ENA users chose their platform because they needed the absolute best tool of its time for the job. But much has changed since then. Today’s devices are becoming highly integrated, requiring more than S-parameter measurements. As device characterization demands more measurement types, higher frequencies, and tighter tolerances, you need to adapt to the current situation and future-proof against new challenges. Gain deeper confidence in your measurements wherever you are with proven hardware and advanced software.

 

Find the Model Tailored to Your Exact Needs

 

The E5081A ENA-X vector network analyzer (VNA) offers advanced integrated noise receivers, direct receiver access, and modulated distortion software on a single test setup, enabling component characterization under high power, complex modulation schemes up to 44 GHz. These features consolidate the design verification setup necessary to conduct reliable characterization, minimizing test cycle time.

 

The E5080B ENA VNA brings excellent performance up to 53 GHz and flexibility to a midrange platform. It provides complete passive and active component characterization in a single instrument.

 

Keysight P50xxB Streamline Series network analyzers bring high-end performance of benchtop instruments into a compact form factor. It’s easy to share these instruments between test locations to make the same measurements reliably. 

 

The M980xA PXIe VNA is a completely independent VNA with 2-, 4- or 6-ports, and the modules are easily configured as a true multiport VNA. A VNA with up to 50-ports can be configured in a single chassis for multiport applications.

 

Performance Comparisons – ENA-X / ENA / Streamline Series VNA / PXI VNA  vs. E5071C ENA 

 

Specifications

 E5081A ENA-X

 E5080B ENA

 P50xxB Streamline Series VNA

 P50xxB Streamline Series VNA

 E5071C ENA

Min frequency

10 MHz

9 kHz / 100 kHz

9 kHz / 100 kHz

9 kHz / 100 kHz

9 kHz / 300 kHz

Max frequency

20 / 44 GHz

4.5 / 6.5 / 9 / 14 / 18 / 20 GHz

26.5 / 32 / 44 / 53 GHz

4.5 / 6.5 / 9 / 14 / 20 GHz

26.5 / 32 / 44 / 53 GHz

4.5 / 6.5 / 9 / 14 / 20 GHz

26.5 / 32 / 44 / 53 GHz

4.5 / 6.5 / 8.5 / 14 / 20 GHz

Number of ports

2 / 4

2 / 4

2 / 4 / 6

2 / 4 / 6

2 / 4

Number of configurable ports

2

0

0

0

0

Max number of ports for full calibration

4

4

12

66

4

Connector type

3.5-mm (m), 2.4-mm (m)

Type-N (f), 3.5-mm (m), 2.4-mm

(m), 1.85-mm (m)

3.5-mm (f), 2.4-mm (f), 1.85-mm (f)

3.5-mm (f), 2.4-mm (f), 1.85-mm (f)

Type-N (f), 3.5-mm (m)

Dynamic range (10 Hz IFBW)

@ 4 GHz

143 dB (port 1 and 2)

140 dB

140 dB

140 dB

123 dB

@ 20 GHz

134 dB (port 1 and 2)

126 dB

126 dB

126 dB

96 dB

Trace noise @ 4 GHz

0.0015 dBrms (10 kHz IFBW)

0.0015 dBrms (10 kHz IFBW)

0.0015 dBrms (10 kHz IFBW)

0.0015 dBrms (10 kHz IFBW)

0.003 dBrms (70 kHz IFBW)

Power sweep range

@ 4 GHz

-80 to 16 dBm (port 1 and 2)

-60 to 10 dBm

-60 to 10 dBm

-60 to 10 dBm

-55 to 10 dBm

@ 20 GHz

-80 to 11 dBm (port 1 and 2)

-60 to 4 dBm

-60 to 4 dBm

-60 to 4 dBm

-25 to 0 dBm

IF bandwidth

1 Hz to 15 MHz

1 Hz to 15 MHz

1 Hz to 15 MHz

1 Hz to 15 MHz

10 Hz to 1.5 MHz

Typical performance

Temperature stability @ 4 GHz

0.005 dB/deg.C

0.005 dB/deg.C

0.005 dB/deg.C

0.005 dB/deg.C

0.005 dB/deg.C

Cycle time (2-port cal, narrow span, 201 points)

2 ms (1 MHz IFBW)

2 ms (1 MHz IFBW)

2 ms (1 MHz IFBW)

2 ms (1 MHz IFBW)

9 ms (500 kHz IFBW)

Hardware features

Display

12.1 inch touchscreen, WXGA

12.1 inch touchscreen, WXGA

Not applicable

Not applicable

10.4 inch touchscreen, XGA

Configurable test set

Yes (port 1 and 2)

No

No

No

No

Low noise receivers for noise figure measurements

Yes (port 1 and 2)

No

No

No

No

Upconverter for modulation distortion analysis

Yes

No

No

No

No

Internal pulse modulators

Yes

Yes

Yes

Yes

No

Internal pulse generators

Yes

Yes

Yes

Yes

No

Internal second source

Yes

Yes

Yes

No

No

High stability timebase

Yes

Yes

No

No

Yes

AUX ports for DC measurements

Yes

Yes

No

No

Yes

Internal DC sources

Yes

Yes

No

No

No

Internal bias tees

No

Yes

No

No

Yes

Display interface

DisplayPort and VGA

DisplayPort and VGA

No

No

VGA

I/O interface

USB/LAN/GPIB/Handler IO

USB/LAN/GPIB/Handler IO

No

USB

USB/LAN/GPIB/Handler IO

×

Please have a salesperson contact me.

*Indicates required field

Select a preferred method of communication*Required Field
Preferred method of communication? Change email?
Preferred method of communication?

By continuing, you are providing Keysight with your personal data. See the Keysight Privacy Statement Informationen darüber, wie wir diese Daten verwenden.

Thank you

A sales representative will contact you soon.

Column Control DTX