保护您的仪器- 将 KeysightCare 服务和全新校准服务添加到您的报价中
ID: U06-2524129
Keysight N7764C
Variable Optical Attenuator (4 Channel) - Single Mode
节省 45%
CNY 113,378.10
原价 CNY 206,142.00

是德科技原厂二手仪器
Keysight N7764C CNY 113,378.10
从
CNY 113,378.10 节省 45%
| 022 | ANGLED CONNECTOR | Installed |
您可以通过索取报价的方式咨询该仪器是否可以定制
安心体验,基于是德科技的专业保障:KeysightCare Assured 服务+ 原厂校准服务
|
Fresh Calibration* 交付周期延长约4周 | CNY 8,353.00 |
|
KeysightCare Assured - 1 year 包括是德科技延长保修 | CNY 7,908.00 |
|
KeysightCare Assured - 2 years 包括是德科技延长保修 | CNY 15,816.00 |
|
KeysightCare Assured - 3 years 包括是德科技延长保修 | CNY 23,724.00 |
|
KeysightCare Assured - 5 years 包括是德科技延长保修 | CNY 39,540.00 |
*若仪器尚未校准(详见商品详情),需先完成校准方可购买 KeysightCare 计划。
The N7764C four-channel variable optical attenuators for single-mode fiber enables highly efficient optical transceiver and network integration testing. It is based on electrically controlled variable optical attenuator (VOA) modules. Applications Optical transceiver testing Optical network integration testing Power Setting and Control Modes In power setting mode, which is available on all N77-C variable optical attenuators, the power level at the attenuator output is set. The N7764C uses the feedback signal from a photodiode after a monitor tap to control the desired power level at the optical output. When power control is active, the instrument also automatically corrects for power changes at the input so that the output power level you set is maintained with ±0.02 dB typical repeatability. Attenuation setting mode In attenuation mode, the calibrated value of attenuation in dB is set directly, without use of the power monitor. This supports use with legacy software written for attenuators without power monitors or when the power monitor reading is impaired, as due to modulation or from a signal at another wavelength or in the reverse direction. Advanced control of power change Especially for testing devices that are sensitive to rapid power changes, the rate of change can be set on the instrument and applies to the attenuation mode. The N7764C can be set from 0.1 to 1000 dB/s. New with the N77-C attenuators is the ability to program a ramp of attenuation steps, including dwell time at each step, which can be either stepped automatically or synchronized with an external trigger. Trigger outputs are also available. This new functionality can be used instead of sending individual program commands for each step and aid in efficient synchronization with other instruments. In power control mode, during attenuation sweeps, as well as when activating the shutter mode, 1000 dB/s change rate is applied. Calibration offsets for external losses Comprehensive offset functionality allows you to calibrate the optical path in various test set-ups. There is an offset for the attenuation factor, and an independent offset for the output power level, to calibrate for losses due to patch cords, connectors, and switches. Additionally, wavelength and offset value pairs can be stored in a table to compensate for wavelength-dependent effects in the optical path of the set-up. This allows you to precisely set the optical power level directly at the input interface of your device under test. New user attenuation-mode calibration To calibrate the attenuation setting mode for a chosen source wavelength, a new self-calibration has been implemented. The calibration process, executed at the chosen wavelength and power higher than 0 dBm, and with the setup kept stable, will run for about 2 minutes. The calibration data can be reenabled after a preset or reboot, or the configuration can be saved with enabled calibration.












