Agilent L44xx Labview Driver Read Me

***********************
**** Read Me First ****
***********************

Version 1.0
June 20, 2006


Introducing the LabVIEW 7.0/7.1 Driver for the Agilent L4400 Series Modules
---------------------------------------------------------------------------
The instrument driver provides access to the functionality of
the Agilent L4400 Series Modules from National Instruments LabVIEW software.


Supported Instruments
---------------------
Module:
L4421A
L4433A
L4437A
L4445A
L4450A
L4451A
L4452A


Installation
-------------
Run the self-extracting ".exe" and verify that the default path is correct for
your \instr.lib directory for LabVIEW. Then click Unzip to complete the installation.
Note. The default path (C:\Program Files\National Instruments\LabVIEW 7.1\instr.lib)
assumes that you have LabVIEW 7.1. If you have LabVIEW 7.0, you will need to change
the path name in the window.

When the installation is complete, a directory structure similar to the following is
created:

\LabVIEW 7.0\instr.lib\agl44xx\
Examples
actstat.counter.mnu
actstat.dac.mnu
actstat.digital.inputmemory.mnu
actstat.digital.mnu
actstat.digital.outputmemory.mnu
actstat.digital.trace.mnu
actstat.mnu
actstat.sequence.mnu
actstat-microwave.mnu
agl44xx.llb
config.dac.mnu
config.digital.input.mnu
config.digital.mnu
config.digital.output.mnu
config.digital.trace.mnu
config.microwave.mnu
config.mnu
config.sequence.mnu
data.advanced.mnu
data.counter.mnu
data.dac.mnu
data.digital.mnu
data.mnu
dir.mnu
utility.mnu

Supported Operating Systems:
Those that support National Instruments LabVIEW.

Disc Space:
Driver: 3,580 k


VISA-COM
Any compliant implementation is acceptable. Typically, VISA-COM is
installed with VISA and other I/O library modules.

If you are using Agilent Technologies' VISA-COM, use
version 2.4.0.4 or later. The latest version of Agilent's IO
Libraries includes the required version of VISA-COM.

I/O
If you are using Agilent Technologies' IO Libraries, use version
M.01.04 or later. You can download the latest version from:
http://www.agilent.com/find/iolibsforivicom

If you are using National Instruments I/O libraries, use NI-VISA
version 3.0.1 or later and NI-488.2 version 2.2 or later.


Known Issues
------------
This driver does not have any known defects.


Revision History
----------------

Version Date Notes
------- --------- -----
1.0 Jun 20, 2006 Initial release


More Information
----------------
For more information about this driver and other instrument drivers
and software available from Agilent Technologies visit:
http://www.agilent.com/find/drivers

A list of contact information is available from:
http://www.agilent.com/find/assist


© Copyright Agilent Technologies, Inc. 2006