Agilent USB Modular DAQ vTools 1.1 are extension
objects that are targeted to work with VEE 9.3. As such,
Agilent USB Modular DAQ vTools 1.1 cannot be installed on PCs that do not have VEE 9.3
installed.
Supported VEE platforms
Agilent USB Modular DAQ vTools 1.1 are targeted
for the following VEE platform, namely:
- VEE Pro 9.3
- VEE RunTime 9.3
- VEE Student 9.3
Please note that to install Agilent USB Modular DAQ vTools 1.1, at least one of the supported
VEE platform stated above must present on the PC.
Installation
will be aborted if none found.
Supported Products
Agilent USB Modular DAQ vTools 1.1 are targeted
for the following USB Modular DAQ, namely:
- Agilent U2300A Series USB Multifunction Data Acquisition : U2331A, U2351A, U2352A, U2353A, U2354A, U2355A, U2356A
- Agilent U2500A Series USB Simultaneous Sampling Multifunction Data Acquisition : U2531A, U2541A, U2542A
System Requirements
Supported Operating Systems:
- Microsoft Windows XP SP3 or higher
- Microsoft Windows Vista SP1 (Business, Enterprise, Ultimate)
- Microsoft Windows 7 32-bit (Professional, Enterprise, Ultimate)
- Microsoft Windows 7 64-bit using WOW64 emulator (Professional, Enterprise, Ultimate)
Software Requirements:
- Agilent IO Libraries Suite 16.1 or higher
- Microsoft .NET Framework 3.5 (SP1)
- Agilent U2781A/U2300A/U2500A/U2600A Series Driver
- Agilent VEE Pro, Agilent VEE RunTime, or Agilent VEE Student (9.3)
Installing the Software
The following describes the installation procedure of Agilent USB Modular DAQ vTools.
- Verify that your PC meets all the minimum requirements listed under System Requirements.
- Follow the instructions on your screen to proceed with the software installation.
- At Setup Type dialog,
- Select Complete to install USB Modular DAQ vTools for all installed VEE (Pro/RunTime/Student). Click Next to proceed.
- Select Custom to install USB Modular DAQ vTools for individual installed VEE (Pro/RunTime/Student). Click Next to proceed.
- Please proceed with the installation and click Finish when the installation has completed.
Uninstall the Software
The following describes the uninstallation procedure of Agilent USB Modular DAQ vTools.
- Go to Start > Settings > Control Panel.
- Double-click Add or Remove Programs.
- Select Agilent USB Modular DAQ vTools 1.1
and click Remove.
- Click Yes to uninstall the software.
Known Issues
Listed below are the known software issues of this release:
- SAD00422309 - USB Modular DAQ vTools fails to run due to wrong VISA address format when U2781A chassis is restarted while VEE program is still open.
- SAD00425023 - vTools Help file will always be shown on top of VEE program until the Help file is minimized.
- SAD00362927 - No undo operation for vTools object that is drag and drop to VEE workspace.
- SAD00443983 - ArrayToFile and FileSpanning objects cannot create file at "C:\" and "C:\Program Files (x86)" on Windows 7 64-bit.
- SAD00431953 - vTools objects did not invoke ModifiedSet if changes were made during program execution.