U2000 Series USB Power SEnsors Firmware Revision History -------------------------------------------------------- Release A1.04.01 (15 Mar 2017) ------------------------------ - Fixed a defect for *TST? self-test intermittent failure in temperature sensor configuration - Bug fixed: After power up, calibration auto will stay ON after "CAL:ZERO:TYPE INT" Release A1.04.00 (15-Apr-2016) ---------------------------- - Released a rebranded firmware in such the default manufacturer is changed from "Agilent Technologies" to "Keysight Technologies". With the firmware change, there are newly introduced SCPI commands. - SYST:PERS:MAN - SYST:PERS:MAN:DEF Refer to the programming guides for more details (http://literature.cdn.keysight.com/litweb/pdf/U2000-90411.pdf?id=1239288) - Fixed a defect such that following a system preset (SYST:PRES), the average count will now updated immediately according to the auto-averaging setting - Fixed measurement (MEAS?) timeout and hang issues when power sensor upper range(POW:AC:RANG 1) is selected to measure lower range power Release A1.03.07 (10-Oct-2015) ---------------------------- - Fixed U2002A external triggering power sweep Release A1.03.06 (10-Aug-2015) ------------------------------ - Fixed source code compilation problem - Fixed average count not updated after SYST:PRES follow by INIT:CONT OFF (or *RST) Release A1.03.05 (26-June-2012) ------------------------------ - Fixed a measurement stability issue when measuring GSM signal in external triggering. Release A1.03.04 (19-June-2012) ------------------------------ - Support U2001A-H25 special option power sensor - Fixed timeout error during *ESR? looping. - Fixed 900ms temperature compensation delay of CW measurement which occurs every 10-15s. Release A1.03.01 (25-May-2010) ------------------------------ Added the following new features/enhancements - Pulse measurements in AVERAGE mode - Pulse Width > 30us - Pulse Period < 8ms - Minimum 1% Duty Cycle - New SCPI ?SYST:PRES BURST - Time gated (aka NORMAL mode) measurement enhancements, applicable to all models except U2004A - Internal Trigger - Signal trace acquisition - Single shot trigger - Measure down to -30 dBm. Previously until -25 dBm - Intermittent USB lockup in gated mode fixed. Note: It is advisable to perform external zeroing on the U2000 Series power sensor for power measurement level below -30 dBm. Release A1.02.01 (23-April-2009) -------------------------------- - Fix intermittent time-gated measurement drop out Release A1.02.00 (12-November-2008) ----------------------------------- The following new features are supported - Time-gated measurement (U2004A model is NOT supported) - Frequency dependant offset table. - Support U2000B,U2001B, U2000H, U2001H, U2002H models Release Release A1.01.03 (8-April-2008) --------------------------------------- - Channel offset fix - AUto zero not completed when cold start industrial PC fix - External trigger slope inversion fix Release A1.01.02 (27-November-2007) ---------------------------------- Enhanced feature - Enabled iDEN signal measurements Release A1.01.01 (2-July-2007) ----------------------------- Initial release.