Release Date Version Version Description
2016-09-08 4.0.60.0 Updated all application to XSA 18.0

Minimum Required Driver Version:

  • M9391A driver: 2.1.230.1
  • M9393A driver (9KHz to 27GHz): 1.2.1016.0
  • M9393A driver (3.6GHz to 50GHz): 2.1.875.1

Recommended Driver Version

  • M9391A driver: 2.1.230.1 or higher
  • M9393A driver (9KHz to 27GHz): 2.0.225.1 or higher
  • M9393A driver (3.6GHz to 50GHz): 2.1.875.1 or higher

Enhancements:

Updated all X-Series measurement applications to version 18.0.

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Install package installs M9000 Measurement Framework, M90XA X-Series Measurement Application and M90XA IVI Drivers
    1. Launch M90XA installer file to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A or M9393A VSAs.

Licensing

  • Requires a License

Supporting Documentation

2016-03-01 3.0.184.0 Updated all application to XSA 17.0

Minimum Required Driver Version:

  • M9391A driver: 2.1.230.1
  • M9393A driver: 1.2.1016.0

Recommended Driver Version

  • M9391A driver: 2.1.230.1 or higher
  • M9393A driver: 2.0.225.1 or higher

Enhancements:

Updated all X-Series measurement applications to version 17.0.

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Install package installs M9000 Measurement Framework, M90XA X-Series Measurement Application and M90XA IVI Drivers
    1. Launch M90XA installer file to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A or M9393A VSAs.

Licensing

  • Requires a License

Supporting Documentation

2015-10-29 3.0.150 LTE and WLAN enhancements (XSA version 16.0) & bug fixes.

Minimum required Drivers:

  • M9391A driver: 1.2.417.1
  • M9393A driver 1.2.1016.0

Recommended Driver Version

  • M9391A driver: 2.1.221.0 or higher
  • M9393A driver 2.0.200.0 or higher

Enhancements:

  • Updated all X-Series measurement applications to version XSA-16.0.
  • Issues fixed in X-Series measurement applications are described in the X-Series Revision History below.

M9068A - Phase Noise Measurement Application

  • Added Minimum Carrier Level setting - Requires M9068A-BTP

  • Log Plot Measurement

  • Added support for Gate functionality - Requires M9068A-BTP

  • Added support for 4801 trace points per sweep (601 default) - Requires M9068A-BTP

  • Added the ability to Export the Marker Table data – Requires M9068A-BTP

M9071A - GSM/EDGE/Evo Measurement Application

  • Added support for multi-carrier test line exception (non-contiguous) - Requires M9071A-BTP

M9064A - VXA Vector Signal Analysis Measurement Application

  • Added support for APCO P25 in analog demodulation measurements

M9077A - WLAN 802.11 a/b/g/n/ac/ah Measurement Application

  • Added M9077A-6TP that adds power and modulation analysis support for WLAN 11ah

  • Added preset for 11p and 11j into radio format

  • Added support for 1024QAM modulation analysis in WLAN 11ac

M9079A - TD-SCDMA/HSPA Measurement Application

  • Added support for E-DCH Fixed reference channel configuration - Requires M9079A-CTP

M9080B- LTE/LTE-Advanced FDD Measurement Application

  • Modulation analysis and conformance EVM updates

  • Simultaneous acquisition of up to 5 component carriers

  • Auto detection of DL CA carrier cross scheduling

  • UE in band emissions for carrier aggregation

  • Spectrum Emission Mask (SEM) updates for Non-contiguous carrier aggregation

  • ACLR for Non-Contiguous CA

  • Inner and outer offset measurements in one measurement sequence

  • Inner-offset CACLR On/Off Auto setup based on Carrier Configuration

  • Occupied bandwidth updates

  • Mode setup updates

  • Added Span soft-keys in Channel Power measurement

M9082B- LTE/LTE-Advanced TDD Measurement Application

  • Modulation analysis and conformance EVM updates

  • Simultaneous acquisition of up to 5 component carriers

  • Auto detection of DL CA carrier cross scheduling

  • UE in band emissions for carrier aggregation

  • Spectrum Emission Mask (SEM) updates for Non-contiguous carrier aggregation

  • ACLR for Non-Contiguous CA

  • Inner and outer offset measurements in one measurement sequence

  • Inner-offset CACLR On/Off Auto setup based on Carrier Configuration

  • Occupied bandwidth updates

  • Mode setup updates

  • Added Span soft-keys in Channel Power measurement

M9081A - Bluetooth Measurement Application

  • Added support to Bluetooth 4.2 for LE data packet length extension, requires M9081A-BTP

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Install package installs M9000 Measurement Framework, M90XA X-Series Measurement Application and M90XA IVI Drivers
    1. Launch M90XA installer file to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A or M9393A VSAs.

Licensing

  • Requires a License

Supporting Documentation

2015-05-11 2.1.509.0 Added phase noise measurement application and more programming examples. Improved measurement speed (XSA version 14.5)

Minimum required Drivers:

  • M9391A driver: 1.2.417.1
  • M9393A driver: 1.1.518.1

Enhancements:

  • Added support for the following measurement application:
    • M9068A - Phase Noise Measurement Application
  • Updated all X-Series measurement applications to version 14.5.
  • Added new MATLAB and Visual Basic .NET programming examples.
  • Measurement speed and performance enhancements in key areas.
  • Issues fixed in X-Series measurement applications are described in the X-Series Revision History below.

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Install package installs M9000 Measurement Framework, M90XA X-Series Measurement Application and M90XA IVI Drivers
    1. Launch M90XA installer file to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A or M9393A VSAs.

Licensing

  • Requires a License

Supporting Documentation

2015-04-02 2.1 Version 2.1

Minimum required Drivers:

  • M9391A driver: 1.2.417.1
  • M9393A driver: 1.1.518.1

Enhancements:

  • Added support for the following measurement application:
    • M9068A - Phase Noise Measurement Application
  • Updated all X-Series measurement applications to version 14.5.
  • Added new MATLAB and Visual Basic .NET programming examples.
  • Measurement speed and performance enhancements in key areas.
  • Issues fixed in X-Series measurement applications are described in the X-Series Revision History below.

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Install package installs M9000 Measurement Framework, M90XA X-Series Measurement Application and M90XA IVI Drivers
    1. Launch M90XA installer file to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A or M9393A VSAs.

Licensing

  • Requires a License

Supporting Documentation

2015-03-09 2.0 Version 2.0

Minimum required Drivers:

  • M9391A driver: 1.1.300
  • M9393A driver: 1.0.70.0

Enhancements:

  • Added support for M9393A PXIe Vector Signal Analyzer.
  • Added support for the following measurement applications:
    • M9063A - Analog Demodulation Measurement Application
    • M9064A - VXA Vector Signal Analysis Measurement Application
    • M9080B - LTE-Advanced FDD Measurement Application
    • M9081A - Bluetooth_® Measurement Application
    • M9082B - LTE-Advanced TDD Measurement Application
      Note: LTE-Advanced applications are NOT supported in 32-bit mode.
  • Updated all X-Series measurement applications to version 14. See X-Series Revision History below.
  • Added support for running in-process with 89600 VSA software and sharing hardware driver sessions.
  • Measurement speed and performance enhancements in key areas.
     

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Install package installs M9000 Measurement Framework, M90XA X-Series Measurement Application and M90XA IVI Drivers
    1. Launch M90XA installer file to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A or M9393A VSAs.

Licensing

  • Requires a License

Supporting Documentation

2013-12-16 1.1 Version 1.1

Agilent's X-Series measurement applications for modular instruments include a unique resource manager that provides direct access to PXI VSA hardware drivers for the fastest power and spectrum-based measurements while simultaneously using fast modulation quality measurements provided in the X-Series measurement applications. Time spent switching between different applications is also significantly faster, thanks to the resource manager.

How to Download

  • Click the Download button
  • Select Run
  • Follow the screen prompts to install the software

How to Install

  • The M90XA Software Installation package installs M90XA X-Series Measurement Applications, M90XA IVI driver, and the M9000 Resource Manager.
    1. Launch M90XA_Setup-1.0.exe to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A Vector Signal Analyzer.

Licensing

  • Requires a License

Supporting Documentation

2013-11-11 1.00 Initial Release: 1.0

Agilent's X-Series measurement applications for modular instruments include a unique resource manager that provides direct access to PXI VSA hardware drivers for the fastest power and spectrum-based measurements while simultaneously using fast modulation quality measurements provided in the X-Series measurement applications. Time spent switching between different applications is also significantly faster, thanks to the resource manager.

How to Download

How to Install

  • The M90XA Software Installation package installs M90XA X-Series Measurement Applications, M90XA IVI driver, and the M9000 Resource Manager.
    1. Launch M90XA_Setup-1.0.exe to run the setup.
    2. Follow the on-screen prompts to complete the installation.
  • Note: The M90XA Software must be installed on the same computer that shares the PXI backplane with the M9391A Vector Signal Analyzer.

Licensing

  • Requires a License

Supporting Documentation