How do I upgrade my E5080B ENA Series Network Analyzer?
1. Hardware Upgrades
E5080B Network Analyzer Frequency Upgrades | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Option (From) | Option (To) | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time1 | Installation note |
E5080B-240 | E5080B-260 | E5080BU-300 | 2port, From 4.5 GHz to 6.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-290 | E5080BU-301 | 2port, From 4.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-2D0 | E5080BU-302 | 2port, From 4.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-2K0 | E5080BU-303 | 2port, From 4.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-260 | E5080B-290 | E5080BU-304 | 2port, From 6.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-2D0 | E5080BU-305 | 2port, From 6.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-2K0 | E5080BU-306 | 2port, From 6.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-290 | E5080B-2D0 | E5080BU-307 | 2port, From 9 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a |
E5080B-2K0 | E5080BU-308 | 2port, From 9 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-2D0 | E5080B-2K0 | E5080BU-309 | 2port, From 14 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-2L0 | E5080B-2M0 | E5080BU-310 | 2port, From 26.5 GHz to 32 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
E5080B-2N0 | E5080BU-311 | 2port, From 26.5 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-2P0 | E5080BU-312 | 2port, From 26.5 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-2M0 | E5080B-2N0 | E5080BU-313 | 2port, From 32 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-2P0 | E5080BU-314 | 2port, From 32 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-2N0 | E5080B-2P0 | E5080BU-315 | 2port, From 44 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
E5080B-440 | E5080B-460 | E5080BU-316 | 4port, From 4.5 GHz to 6.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-490 | E5080BU-317 | 4port, From 4.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-4D0 | E5080BU-318 | 4port, From 4.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-4K0 | E5080BU-319 | 4port, From 4.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-460 | E5080B-490 | E5080BU-320 | 4port, From 6.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4D0 | E5080BU-321 | 4port, From 6.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-4K0 | E5080BU-322 | 4port, From 6.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-490 | E5080B-4D0 | E5080BU-323 | 4port, From 9 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a |
E5080B-4K0 | E5080BU-324 | 4port, From 9 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-4D0 | E5080B-4K0 | E5080BU-325 | 4port, From 14 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4L0 | E5080B-4M0 | E5080BU-326 | 4port, From 26.5 GHz to 32 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
E5080B-4N0 | E5080BU-327 | 4port, From 26.5 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-4P0 | E5080BU-328 | 4port, From 26.5 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-4M0 | E5080B-4N0 | E5080BU-329 | 4port, From 32 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4P0 | E5080BU-330 | 4port, From 32 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-4N0 | E5080B-4P0 | E5080BU-331 | 4port, From 44 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
E5080B-442 | E5080B-462 | E5080BU-332 | 4port, 2nd source, From 4.5 GHz to 6.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-492 | E5080BU-333 | 4port, 2nd source, From 4.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-4D2 | E5080BU-334 | 4port, 2nd source, From 4.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-4K2 | E5080BU-335 | 4port, 2nd source, From 4.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-462 | E5080B-492 | E5080BU-336 | 4port, 2nd source, From 6.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4D2 | E5080BU-337 | 4port, 2nd source, From 6.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-4K2 | E5080BU-338 | 4port, 2nd source, From 6.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-492 | E5080B-4D2 | E5080BU-339 | 4port, 2nd source, From 9 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a |
E5080B-4K2 | E5080BU-340 | 4port, 2nd source, From 9 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 3.2 hrs | n/a | |
E5080B-4D2 | E5080B-4K2 | E5080BU-341 | 4port, 2nd source, From 14 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4L2 | E5080B-4M2 | E5080BU-342 | 4port, 2nd source, From 26.5 GHz to 32 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
E5080B-4N2 | E5080BU-343 | 4port, 2nd source, From 26.5 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-4P2 | E5080BU-344 | 4port, 2nd source, From 26.5 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-4M2 | E5080B-4N2 | E5080BU-345 | 4port, 2nd source, From 32 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4P2 | E5080BU-346 | 4port, 2nd source, From 32 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a | |
E5080B-4N2 | E5080B-4P2 | E5080BU-347 | 4port, 2nd source, From 44 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
Important: Frequency upgrades require the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
E5080B Network Analyzer Test Port Upgrades |
---|
No test Port Upgrade is available on E5080B.
E5080B Network Analyzer Add Spectrum analysis hardware | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Option (To) | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time1 | Installation note |
E5080B-090 | E5080BU-090 | Add Spectrum analysis hardware for 4.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-091 | E5080BU-091 | Add Spectrum analysis hardware for 6.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-092 | E5080BU-092 | Add Spectrum analysis hardware for 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-093 | E5080BU-093 | Add Spectrum analysis hardware for 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-094 | E5080BU-094 | Add Spectrum analysis hardware for 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-095 | E5080BU-095 | Add Spectrum analysis hardware for 26.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-096 | E5080BU-096 | Add Spectrum analysis hardware for 33 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-097 | E5080BU-097 | Add Spectrum analysis hardware for 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-098 | E5080BU-098 | Add Spectrum analysis hardware for 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
Important: Add Spectrum analysis hardware requires S96090A Spectrum Analysis software.
Important: Add Spectrum analysis hardware requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
E5080B Network Analyzer Update Spectrum analysis hardware | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Option (From) | Option (To) | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time1 | Installation note |
E5080B-090 | E5080B-091 | E5080BU-800 | From 4.5 GHz to 6.5 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-092 | E5080BU-801 | From 4.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-093 | E5080BU-802 | From 4.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-094 | E5080BU-803 | From 4.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-091 | E5080B-092 | E5080BU-804 | From 6.5 GHz to 9 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-093 | E5080BU-805 | From 6.5 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-094 | E5080BU-806 | From 6.5 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-092 | E5080B-093 | E5080BU-807 | From 9 GHz to 14 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-094 | E5080BU-808 | From 9 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-093 | E5080B-094 | E5080BU-809 | From 14 GHz to 20 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-095 | E5080B-096 | E5080BU-810 | From 26.5 GHz to 32 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-097 | E5080BU-811 | From 26.5 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-098 | E5080BU-812 | From 26.5 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-096 | E5080B-097 | E5080BU-813 | From 32 GHz to 44 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-098 | E5080BU-814 | From 32 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a | |
E5080B-097 | E5080B-098 | E5080BU-815 | From 44 GHz to 53 GHz | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
Important: Update Spectrum analysis hardware requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
E5080B Network Analyzer – Add Vector Spectrum Analysis Hardware | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Option (To) | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time1 | Installation note |
E5080B-190 | E5080BU-190 | Add Vector Signal Analysis hardware | Hardware | No | Customer Not installable | A.17.05.10 | Non opt-09x unit (Opt-09x is required) | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
E5080BU-190 adds vector signal analysis capabilities to spectrum analysis option. Your E5080B must be equipped with E5080B-090 to E5080B-098 spectrum analysis option. Also, S96090B (Spectrum Analysis software) is required.
Important: Add Vector Spectrum Analysis Hardware requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
E5080B Network Analyzer – Add second source hardware upgrades | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Option (From) | Option (To) | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time1 | Installation note |
E5080B-4L0 | E5080B-4L2 | E5080BU-4L2 | Add second source hardware for E5080B-4L0 | Hardware | No | Customer Not installable | n/a | E5080B-240/260/290/2D0/2K0/
| Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4M0 | E5080B-4M2 | E5080BU-4M2 | Add second source hardware for E5080B-4M0 | Hardware | No | Customer Not installable | n/a | E5080B-240/260/290/2D0/2K0/
| Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4N0 | E5080B-4N2 | E5080BU-4N2 | Add second source hardware for E5080B-4N0 | Hardware | No | Customer Not installable | n/a | E5080B-240/260/290/2D0/2K0/
| Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-4P0 | E5080B-4P2 | E5080BU-4P2 | Add second source hardware for E5080B-4P0 | Hardware | No | Customer Not installable | n/a | E5080B-240/260/290/2D0/2K0/
| Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
Important: Add second source hardware upgrade requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
E5080B Network Analyzer Hardware Upgrades | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Option (To) | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time1 | Installation note |
E5080B-021 | E5080BU-021 | Add Pulse Modulation 1st source | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-022 | E5080BU-022 | Add Pulse Modulation 2nd source | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 1.3 hrs | n/a |
E5080B-120 | E5080BU-120 | Add internal bias tees for 2port up to 20 GHz | Hardware | No | Customer Not installable | n/a | E5080B- 2L0/2M0/ 2N0/2P0 | Yes | Keysight Technologies Service Center – 2.2 hrs | n/a |
E5080B-140 | E5080BU-140 | Add internal bias tees for 4port up to 20 GHz | Hardware | No | Customer Not installable | n/a | E5080B- 4L0/4M0/ 4N0/4P0/ 4L2/4M2/ 4N2/4P2 | Yes | Keysight Technologies Service Center – 2.5 hrs | n/a |
E5080B-172 | E5080BU-172 | Add GPIB interface | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 5 hrs | n/a |
E5080B-175 | E5080BU-175 | Add analog input and output | Hardware | No | Customer Not installable | n/a | n/a | No | Keysight Technologies Service Center – 2.5 hrs | n/a |
n/a | E5080BU-180 | Spare SSD | Hardware | No | Customer installable | n/a | E5080B with serial number prefix of MY593, SG593 | No | Customer - 0.5 hrs | E5080-90102 |
n/a | E5080BU-181 | Spare SSD | Hardware | No | Customer installable | A.17.05.10 | E5080B with serial number prefix of MY591/2, SG591/2 | No | Customer - 0.5 hrs | E5080-90102 |
E5080B-1E5 | E5080BU-1E5 | High stability timebase | Hardware | No | Customer Not installable | n/a | n/a | Yes | Keysight Technologies Service Center – 2.3 hrs | n/a |
1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
Important: Add Pulse modulation (E5080BU-021/022) requires S96025A Basic Pulsed-RF Measurements software.
Important: The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
2. Software Upgrades
E5080B Network Analyzer Software Upgrades | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Required Hardware upgrade option | Order with this number | Description | Type | eDelivery | Upgrade Contents | Minimum Firmware | Incompatible With | Adjustments required after installation | Installed by & Installation Time | Installation note |
n/a | S96007B | Automatic fixture removal | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96010B | Time domain analysis | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96011B | Enhanced time domain analysis with TDR | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96015B | Real-time S-Parameter and Power Measurement Uncertainty | Software | Yes | License Key (*1) | A.14.70.01 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
E5080BU-021/022 | S96025B | Basic pulsed-RF measurements | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96029B | Noise figure measurement with vector correction | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96082B | Scalar mixer/converter measurements | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96083B | Vector and Scalar mixer/converter measurements | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96084B | Embedded LO capability | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96086B | Gain-compression measurement | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96089B | Differential and I/Q devices measurements | Software | License Key (*1) | A.14.10.12 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. | |
E5080BU- 090/091/092/ 093/094/095/ 096/097/098 | S96090B | Spectrum Analysis | Software | Yes | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
n/a | S96460B | Integrated True Mode Stimulus Application | Software | License Key (*1) | A.14.70.01 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. | |
n/a | S96552B | Multiport calibration Assistant | Software | License Key (*1) | A.14.10.03 | n/a | No | Customer - 0.5 hrs | Instruction is provided by e-mail through FlexNet. |
(*1) This software upgrades will require the redemption and installation of a license key file to activate the option. Once a redemption certificate is received the license key file can be redeemed at the Keysight Software License Redemption Website.
3. Firmware Upgrades