How do I upgrade my E5080B ENA Series Network Analyzer?

 1. Hardware Upgrades

E5080B Network Analyzer Frequency Upgrades
Option
(From)
 
Option
(To)
 
Order with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation Time1Installation note
 E5080B-240E5080B-260  E5080BU-300 2port, From 4.5 GHz to 6.5 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-290 E5080BU-301 2port, From 4.5 GHz to 9 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-2D0 E5080BU-302 2port, From 4.5 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-2K0 E5080BU-303 2port, From 4.5 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-260 E5080B-290 E5080BU-304 2port, From 6.5 GHz to 9 GHz Hardware NoCustomer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-2D0 E5080BU-305 2port, From 6.5 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-2K0 E5080BU-306 2port, From 6.5 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-290 E5080B-2D0 E5080BU-307 2port, From 9 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-2K0 E5080BU-308 2port, From 9 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-2D0 E5080B-2K0 E5080BU-309 2port, From 14 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-2L0 E5080B-2M0 E5080BU-310 2port, From 26.5 GHz to 32 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-2N0E5080BU-311  2port, From 26.5 GHz to 44 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-2P0 E5080BU-312 2port, From 26.5 GHz to 53 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-2M0 E5080B-2N0 E5080BU-313 2port, From 32 GHz to 44 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-2P0 E5080BU-314 2port, From 32 GHz to 53 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-2N0 E5080B-2P0 E5080BU-315 2port, From 44 GHz to 53 GHz Hardware No Customer Not installable n/a n/a YesKeysight Technologies Service Center – 2.3 hrs n/a
 E5080B-440 E5080B-460 E5080BU-316 4port, From 4.5 GHz to 6.5 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-490 E5080BU-317 4port, From 4.5 GHz to 9 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-4D0 E5080BU-318 4port, From 4.5 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-4K0 E5080BU-319 4port, From 4.5 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-460 E5080B-490 E5080BU-320 4port, From 6.5 GHz to 9 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-4D0 E5080BU-321 4port, From 6.5 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-4K0 E5080BU-322 4port, From 6.5 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-490 E5080B-4D0 E5080BU-323 4port, From 9 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-4K0 E5080BU-324 4port, From 9 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-4D0 E5080B-4K0 E5080BU-325 4port, From 14 GHz to 20 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-4L0 E5080B-4M0 E5080BU-326 4port, From 26.5 GHz to 32 GHz Hardware NoCustomer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4N0 E5080BU-327 4port, From 26.5 GHz to 44 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4P0 E5080BU-328 4port, From 26.5 GHz to 53 GHz Hardware No Customer Not installable n/an/a Yes Keysight Technologies Service Center – 2.3 hrsn/a
 E5080B-4M0 E5080B-4N0 E5080BU-329 4port, From 32 GHz to 44 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-4P0 E5080BU-330 4port, From 32 GHz to 53 GHz Hardware NoCustomer Not installable  n/an/a  Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4N0 E5080B-4P0 E5080BU-331 4port, From 44 GHz to 53 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-442 E5080B-462 E5080BU-332 4port, 2nd source, From 4.5 GHz to 6.5 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-492 E5080BU-333 4port, 2nd source, From 4.5 GHz to 9 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 1.3 hrsn/a
 E5080B-4D2 E5080BU-334 4port, 2nd source, From 4.5 GHz to 14 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 3.2 hrsn/a
 E5080B-4K2 E5080BU-335 4port, 2nd source, From 4.5 GHz to 20 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-462 E5080B-492 E5080BU-336 4port, 2nd source, From 6.5 GHz to 9 GHz Hardware No Customer Not installable n/an/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-4D2 E5080BU-337 4port, 2nd source, From 6.5 GHz to 14 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-4K2 E5080BU-338 4port, 2nd source, From 6.5 GHz to 20 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-492 E5080B-4D2 E5080BU-339 4port, 2nd source, From 9 GHz to 14 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 3.2 hrs n/a
 E5080B-4K2E5080BU-340  4port, 2nd source, From 9 GHz to 20 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 3.2 hrsn/a
 E5080B-4D2 E5080B-4K2 E5080BU-341 4port, 2nd source, From 14 GHz to 20 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a
 E5080B-4L2 E5080B-4M2 E5080BU-342 4port, 2nd source, From 26.5 GHz to 32 GHz Hardware NoCustomer Not installable  n/a n/aYes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4N2 E5080BU-343 4port, 2nd source, From 26.5 GHz to 44 GHz Hardware NoCustomer Not installable  n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4P2 E5080BU-344 4port, 2nd source, From 26.5 GHz to 53 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4M2 E5080B-4N2 E5080BU-345 4port, 2nd source, From 32 GHz to 44 GHz Hardware No Customer Not installable n/a n/aYes Keysight Technologies Service Center – 1.3 hrsn/a
 E5080B-4P2 E5080BU-346 4port, 2nd source, From 32 GHz to 53 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrs n/a
 E5080B-4N2 E5080B-4P2 E5080BU-347 4port, 2nd source, From 44 GHz to 53 GHz Hardware No Customer Not installable n/a n/a Yes Keysight Technologies Service Center – 2.3 hrsn/a

1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.

Important: Frequency upgrades require the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.


E5080B Network Analyzer Test Port Upgrades

No test Port Upgrade is available on E5080B.

E5080B Network Analyzer Add Spectrum analysis hardware
Option
(To)
 
Order with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation Time1Installation note
E5080B-090E5080BU-090Add Spectrum analysis hardware for 4.5 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-091E5080BU-091Add Spectrum analysis hardware for 6.5 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-092E5080BU-092Add Spectrum analysis hardware for 9 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-093E5080BU-093Add Spectrum analysis hardware for 14 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-094E5080BU-094Add Spectrum analysis hardware for 20 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-095E5080BU-095Add Spectrum analysis hardware for 26.5 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-096E5080BU-096Add Spectrum analysis hardware for 33 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-097E5080BU-097Add Spectrum analysis hardware for 44 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-098E5080BU-098Add Spectrum analysis hardware for 53 GHzHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a

1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.

Important: Add Spectrum analysis hardware requires S96090A Spectrum Analysis software.
Important: Add Spectrum analysis hardware requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.


E5080B Network Analyzer Update Spectrum analysis hardware
Option
(From)
 
Option
(To)
 
Order with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation Time1Installation note
E5080B-090E5080B-091E5080BU-800From 4.5 GHz to 6.5 GHzHardwareNoCustomer Not installable n/a n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-092E5080BU-801From 4.5 GHz to 9 GHzHardwareNo Customer Not installable  n/a  n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-093E5080BU-802From 4.5 GHz to 14 GHzHardwareNo Customer Not installable n/a  n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-094E5080BU-803From 4.5 GHz to 20 GHzHardware No Customer Not installable n/a  n/a YesKeysight Technologies Service Center – 1.3 hrs  n/a
 E5080B-091E5080B-092E5080BU-804From 6.5 GHz to 9 GHzHardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-093E5080BU-805 From 6.5 GHz to 14 GHz  Hardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-094E5080BU-806 From 6.5 GHz to 20 GHz Hardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-092E5080B-093 E5080BU-807 From 9 GHz to 14 GHz  Hardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs  n/a
E5080B-094 E5080BU-808From 9 GHz to 20 GHzHardwareNo Customer Not installable  n/a n/aYesKeysight Technologies Service Center – 1.3 hrs  n/a
E5080B-093E5080B-094 E5080BU-809 From 14 GHz to 20 GHz Hardware No Customer Not installable  n/a n/aYesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-095E5080B-096 E5080BU-810 From 26.5 GHz to 32 GHz Hardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs  n/a
E5080B-097 E5080BU-811 From 26.5 GHz to 44 GHz Hardware No Customer Not installable  n/an/a YesKeysight Technologies Service Center – 1.3 hrs  n/a
E5080B-098 E5080BU-812 From 26.5 GHz to 53 GHz Hardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs n/a
E5080B-096E5080B-097 E5080BU-813 From 32 GHz to 44 GHzHardware No Customer Not installable  n/a n/aYesKeysight Technologies Service Center – 1.3 hrs  n/a
E5080B-098 E5080BU-814 From 32 GHz to 53 GHz Hardware No Customer Not installable  n/a n/a YesKeysight Technologies Service Center – 1.3 hrs  n/a
E5080B-097 E5080B-098 E5080BU-815 From 44 GHz to 53 GHz Hardware No Customer Not installable  n/a n/a Yes Keysight Technologies Service Center – 1.3 hrs n/a

1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.
 

Important: Update Spectrum analysis hardware requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.
 

 E5080B Network Analyzer – Add Vector Spectrum Analysis Hardware
Option
(To)
 
Order with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation Time1Installation note
E5080B-190E5080BU-190Add Vector Signal Analysis hardwareHardwareNoCustomer Not installableA.17.05.10

Non opt-09x unit (Opt-09x is required)


YesKeysight Technologies Service Center – 1.3 hrsn/a

1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.

E5080BU-190 adds vector signal analysis capabilities to spectrum analysis option. Your E5080B must be equipped with E5080B-090 to E5080B-098 spectrum analysis option. Also, S96090B (Spectrum Analysis software) is required. 

Important: Add Vector Spectrum Analysis Hardware requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.


 E5080B Network Analyzer – Add second source hardware upgrades
Option
(From)
 
Option
(To)
 
Order with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation Time1Installation note
E5080B-4L0E5080B-4L2E5080BU-4L2Add second source hardware for E5080B-4L0HardwareNoCustomer Not installablen/a

E5080B-240/260/290/2D0/2K0/
2L0/2M0/
2N0/2P0


E5080B-440/460/490/4D0/4K0
 

YesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-4M0E5080B-4M2E5080BU-4M2Add second source hardware for E5080B-4M0HardwareNoCustomer Not installablen/a

E5080B-240/260/290/2D0/2K0/
2L0/2M0/
2N0/2P0


E5080B-440/460/490/4D0/4K0
 

YesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-4N0E5080B-4N2E5080BU-4N2Add second source hardware for E5080B-4N0HardwareNoCustomer Not installablen/a

E5080B-240/260/290/2D0/2K0/
2L0/2M0/
2N0/2P0


E5080B-440/460/490/4D0/4K0
 

YesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-4P0E5080B-4P2E5080BU-4P2Add second source hardware for E5080B-4P0HardwareNoCustomer Not installablen/a

E5080B-240/260/290/2D0/2K0/
2L0/2M0/
2N0/2P0


E5080B-440/460/490/4D0/4K0
 

YesKeysight Technologies Service Center – 1.3 hrsn/a

 1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.

Important: Add second source hardware upgrade requires the full adjustments and performance test. The completion of a part of calibration (adjustments and performance tests) does verify the functionality of the option, but does not guarantee that the instrument meets all published specifications. A full calibration is the only way to guarantee the analyzer specifications are being met. The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.


E5080B Network Analyzer Hardware Upgrades
Option
(To)
 
Order with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation Time1Installation note
E5080B-021E5080BU-021Add Pulse Modulation 1st sourceHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-022E5080BU-022Add Pulse Modulation 2nd sourceHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 1.3 hrsn/a
E5080B-120E5080BU-120Add internal bias tees for 2port up to 20 GHzHardwareNoCustomer Not installablen/aE5080B-
2L0/2M0/
2N0/2P0
 
YesKeysight Technologies Service Center – 2.2 hrsn/a
E5080B-140E5080BU-140Add internal bias tees for 4port up to 20 GHzHardwareNoCustomer Not installablen/aE5080B-
4L0/4M0/
4N0/4P0/
4L2/4M2/
4N2/4P2
YesKeysight Technologies Service Center – 2.5 hrsn/a
E5080B-172E5080BU-172Add GPIB interfaceHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 5 hrsn/a
E5080B-175E5080BU-175Add analog input and outputHardwareNoCustomer Not installablen/an/aNoKeysight Technologies Service Center – 2.5 hrsn/a
n/aE5080BU-180Spare SSDHardwareNoCustomer installablen/aE5080B with serial number prefix of MY593, SG593NoCustomer - 0.5 hrsE5080-90102
n/aE5080BU-181Spare SSDHardwareNoCustomer installableA.17.05.10E5080B with serial number prefix of MY591/2, SG591/2NoCustomer - 0.5 hrsE5080-90102
E5080B-1E5E5080BU-1E5High stability timebaseHardwareNoCustomer Not installablen/an/aYesKeysight Technologies Service Center – 2.3 hrsn/a

 1 The installation time stated only includes adjustment and verification time. Additional labor charges may apply.

Important: Add Pulse modulation (E5080BU-021/022) requires S96025A Basic Pulsed-RF Measurements software.

Important: The upgrade labor and calibration charges need to be quoted at the same time of the upgrade kit quotation.


 2. Software Upgrades

E5080B Network Analyzer Software Upgrades
Required Hardware upgrade optionOrder with this numberDescriptionTypeeDeliveryUpgrade ContentsMinimum FirmwareIncompatible WithAdjustments required after installationInstalled by & Installation TimeInstallation note
n/aS96007BAutomatic fixture removalSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96010BTime domain analysisSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96011BEnhanced time domain analysis with TDRSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96015BReal-time S-Parameter and Power Measurement UncertaintySoftwareYesLicense Key (*1)A.14.70.01n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
E5080BU-021/022S96025BBasic pulsed-RF measurementsSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96029BNoise figure measurement with vector correctionSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96082BScalar mixer/converter measurementsSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96083BVector and Scalar mixer/converter measurementsSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96084BEmbedded LO capabilitySoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/aS96086BGain-compression measurementSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.
n/a

S96089B

Differential and I/Q devices measurements

Software

Yes

License Key (*1)

A.14.10.12

n/a

No

Customer - 0.5 hrs

Instruction is provided by e-mail through FlexNet.

E5080BU-
090/091/092/
093/094/095/
096/097/098
S96090BSpectrum AnalysisSoftwareYesLicense Key (*1)A.14.10.03n/aNoCustomer - 0.5 hrsInstruction is provided by e-mail through FlexNet.

n/a

S96460B

Integrated True Mode Stimulus Application

Software

Yes

License Key (*1)

A.14.70.01

n/a

No

Customer - 0.5 hrs

Instruction is provided by e-mail through FlexNet.

n/a

S96552B

Multiport calibration Assistant

Software

Yes

License Key (*1)

A.14.10.03

n/a

No

Customer - 0.5 hrs

Instruction is provided by e-mail through FlexNet.

 (*1) This software upgrades will require the redemption and installation of a license key file to activate the option. Once a redemption certificate is received the license key file can be redeemed at the Keysight Software License Redemption Website.

3. Firmware Upgrades

 
 