Voici la page que nous pensons que vous vouliez. Voir les résultats de la recherche au lieu:

 

Discutez avec un expert

Support technique

Mesure Electronique

Support by Product Model Number:

26-50 sur 78

Tri:
The Benefits of Updating Your 3499A/B/C Switching System to the 34980A Switch/Measure Unit
This application note will describe differences and advantages of the new 34980A as compared to the 3499A/B/C.

Notes d’application 2013-08-15

Optimize burn-in test with the Keysight 34980A multifunction switch/measure unit apnote overview
This application overview will discuss the complexities of burn-in test based on the Keysight 340980A switch/measure unit

Notes d’application 2013-01-31

PDF PDF 440 KB
Comparing the Keysight 34980A and PXI for Switch Measurement Applications
This application note provides a comparison between PXI cardcage solutions and a combined system, the Keysight 34980A switch/measure unit, so you can determine which platform best meets your needs for electronic functional test and data acquisition.

Notes d’application 2012-04-27

Making Good Thermocouple Measurements
This application note provides tips for optimizing thermocouple measurements in a noisy environment.

Notes d’application 2012-01-26

PDF PDF 552 KB
Selecting the Correct Temperature Sensor for Your Application
This application note provides tips for selecting the correct temperature sensor.

Notes d’application 2012-01-25

PDF PDF 543 KB
Design Tutorial: E5061B ENA Custom Multiport Switch Solution Using L4491A
This application note describes how to configure a 12-port custom switch box with the L4491A switch platform and operation basics using the E5061B network analyzer.

Notes d’application 2011-11-29

PDF PDF 1016 KB
Making High-Accuracy Temperature Measurements with the 34970A/34972A Data Acquisition Switch Unit
This application note explains how to wire the VTI Instruments VT1586A rack-mount panel and use it to make high-accuracy temperature measurements with a 34970A, 34972A and 34901A 20-channel multiplexer module.

Notes d’application 2011-01-10

Switching Solutions
This paper discusses Keysight's complete line of switching solutions. Switch components are introduced, followed by the various scale of switch matrix that is required in RF and microwave testing.

Notes d’application 2010-11-18

Efficient use of data logging and decision making w multiple scan lists
Basic data logging allows you to confi gure different measurements across multiple channels, then record the data.

Notes d’application 2010-04-07

PDF PDF 486 KB
Types of Data Acquisition Architectures
To help you choose a system that meets your needs, this article explains the different types of data acquisition system architectures and explores some of the advantages and disadvantages.

Notes d’application 2010-02-01

Migrating your Application Software from the 34970A to the 34972A
This white paper discusses how to migrate from existing applications that use the 34970A to the new 34972A Data Acquisition/Switch Unit.

Notes d’application 2010-01-29

PDF PDF 281 KB
Solar Cell and Module Testing
This application note describes how to decrease costs and increase flexibility for solar cell and module testing with Keysight products and solutions.

Notes d’application 2009-12-07

Tips for Optimizing Your Switch Matrix Performance
This application note offers eight tips to help you optimize your measurement matrix switching performance and important features to remember when designing your switching solution.

Notes d’application 2009-10-22

Using the U2331A USB DAQ in the construction industry
The device can be used to measure various types of parameters in the construction industry.

Notes d’application 2009-04-06

PDF PDF 229 KB
Tips in Using Keysight GPIB Solutions in National Instrument’s LabVIEW Environment- Application Note
Tips for using Keysight GPIB solutions in National Instrument’s LabVIEW environment.

Notes d’application 2009-03-04

DC-to-DC Regulator Auto Evaluation Test with the U2351A
The Keysight U2351A data acquisition (DAQ) is used as an automatic DC voltage regulator and to induce voltage into the electronics system thereby causing an amount of under voltage or over voltage stress to the device under test (DUT).

Notes d’application 2009-02-04

PDF PDF 270 KB
Application Note: Tips & Tricks for Using USB, GPIB, & LAN (AN 1465-20)
Application Note: Tips & Tricks for Connectivity

Notes d’application 2009-01-22

Simplified PC Connections for GPIB Instruments (AN 1409-1) - Application Note
Making the connection from your instruments to your PC has not always been an easy task. Today there are new choices that allow for easier connections so that you can focus on your measurement tasks and not on your connections. This paper will walk you through the choices you need to make when...

Notes d’application 2009-01-22

High-Speed Scanning with the Keysight 34980A Multifunction Switch/Measure Mainframe and Modules
This application note explores components that affect the speed in a system. It also gives a breakdown of each component with SCPI language examples of how to set up the instrument for fast measurements that best fit your specific application.

Notes d’application 2008-11-26

Boosting PLL Design Efficiency From free-running VCO characterizations to closed-loop PLL evaluation
This application note describes introduces practical solutions for VCO/PLL performance evaluation and gives actual examples of parameter measurements using the E5052B.

Notes d’application 2008-11-21

Responding to data logging events using action scripts
Combining data logging hardware and software can give you more techniques to automate extensive and repetitious measurements.

Notes d’application 2008-10-30

Improve your data logging productvity using advanced limit testing
Improve your data logging productvity using advanced limit testing

Notes d’application 2008-10-30

PDF PDF 456 KB
DVD Player Manufacturing Test Using Keysight Modular Instruments
Audio and video testing of modern digital video disc (DVD) player using Keysight’s USB modular oscilloscopes and USB modular switch matrix.

Notes d’application 2008-09-15

Using USB and LAN I/O Converters - Application Note
Compare 3 instrument connectivity products to determine which interconnect device is best for your application needs.

Notes d’application 2008-07-09

PDF PDF 194 KB
Automotive Power Window Regulator Testing - Application Note
Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters such as window movement, acceleration of the window movement in both directions, maximum range of movement, torque exerted at the start, the end stall torque, and motor load characteristics.

Notes d’application 2008-06-30

PDF PDF 280 KB

Précédente 1 2 3 4 Page suivante