What should you do prior to executing iVTEP?
"Undo AutoDebug" to enable back all commented pins during VTEP AutoDebug. Enable the commented pins to be debugged using iVTEP.

FAQ 2007-09-12

What is the short-cut key for "faoff" at Engineer?
Shift+F2.

FAQ 2007-09-12

How to pause test execution queue?
Click "Pause" button.

FAQ 2007-09-12

How to display short format for the Column Name?
Click "Edit-Preferences", go to Engineer Test Tab, select "Short" and click OK.

FAQ 2007-09-12

Can user define the CPK for optimizer?
Yes. This menu can be accessed at "Actions-Optimizer-Rule Editor".

FAQ 2007-09-12

What is the short-cut key for "faon" at Engineer?
F2.

FAQ 2007-09-12

How to remove "Test Output"?
Uncheck all the above components in "View-Engineer-Test Output".

FAQ 2007-09-12

Can I run Auto-Optimizer with Control XT Card?
No, you must have Control XTP Cards to run Auto-Optimizer.

FAQ 2007-09-12

What is the password for login to Engineer Test?
"engineer" password is "engineer" OR "user" password is "user".

FAQ 2007-09-12

How to remove the "Test Execution"?
Uncheck "View-Engineer-Test Execution".

FAQ 2007-09-12

How do you add a "switch" icon on the desktop?
At Korn Shell or DOS window, execute "C:\Agilent_ICT\util\switch\switch i3070".

FAQ 2007-09-12

How to clear Output windows?
Click "View?Engineer?Clear Output" or Use short-cut key "Ctrl+Alt+A".

FAQ 2007-09-12

我該如何解密或消毒我的 1660A 系列邏輯分析儀?
此牽涉到遵循將所有使用者資料從儀器記憶體中清除的程序。

FAQ 2007-07-10

可以在 Keysight 4291A/B 阻抗分析儀上利用「標準網路分析儀校驗套件」來執行測試頭校驗嗎?
包括 Keysight 4291A/B 標準套件支援 Keysight 4291A/B 阻抗分析儀上的測試頭校驗。

FAQ 2007-05-29

My Keysight 4284A / 4285A LCR Meter is indicating an "ADC ERR" error message. What are the corrective actions?
The error message is an indication that the LCR meter's A/D converter within the measurement circuit is malfunctioning.

FAQ 2007-05-03

我在 Keysight 8753ES 分析儀上接收到以下警告:"Caution:No if found:Check R input level"。應該採取什麼修正動作呢?

FAQ 2007-02-26

嘗試在 Keysight PNA 系列網路分析儀上執行系統驗證時,出現「Remote Server Not Available」錯誤訊息。為什麼?

FAQ 2007-01-21

Keysight PNA 系列網路分析儀 Bias Tee 輸入保險絲的是德零件編號為何?
Keysight PNA 系列網路分析儀 bias tee 輸入保險絲的替換零件編號為是德零件編號 2110-0046。

FAQ 2006-11-30

What is the Keysight part number for the CR2032 3V Lithium battery used on the CPU board in the 5483x, 5485x, MSO8000, and DSO80000 Series Infiniium...
The Keysight part number is 1420-0356. However, this is a very common battery and may be available at camera shops, electronic suppliers, etc.

FAQ 2006-11-13

What are the items necessary to remove and replace an APC-7 (7mm) connector collets?
The APC-7 center conductor collet (85050-20001) and the APC-7 connector collet extractor tool (5060-0370)

FAQ 2006-10-31

Keysight 33220A 函數/任意波形產生器中,主電源供應器組件的保險絲額定值為何?
重要:更換整個電源供應器。保險絲類型 UL/IEC127,額定值 250VAC H 3.15A

FAQ 2006-10-02

我該如何判斷 Keysight 8153A 主機的韌體版本?
您可執行下列步驟判斷 Keysight 8153A 主機的韌體版本。

FAQ 2006-10-01

34970A: How do I confirm that my RS-232 cable is working properly?
By placing a short on one end of the RS-232 cable and connecting the other to a PC, you can use Hyperterminal to verify if the cable is working properly.

FAQ 2006-08-29

How is the 34970A Multiplexer Modules Thermocouple Cold Junction Reference Temperature Calibrated?
Use the procedure for the 34901A, 34902A, 34908A modules reference junction verification and adjustment are located in the 34970A Service Guide.

FAQ 2006-08-29

34970A: Is it possible to measure the relay cycle count?
The instrument has a relay maintenance system to help predict relay end-of-life.

FAQ 2006-08-29