오래된 고성능 튜닝형 레이저 소스에 맞는 펌웨어를 어디서 찾을 수 있습니까?

FAQ 2004-10-12

How do I upgrade or reinstall my 54800-series oscilloscope's operating system and scope software?
Upgrade and recovery software is available free of charge at ...

FAQ 2004-07-29

What is the End of Support date for my Keysight 8990A/8991A/8992A Power Analyzer?
01-March-2004.

FAQ 2004-07-27

Can the line module in my EPM/EPM-P series power meter be replaced at my local Service Center?
This will depend on the model number and the date of manufacture.

FAQ 2004-07-12

What is the End of Support date for my Keysight E4418A/19A Power Meter?
01-March-2004.

FAQ 2004-05-23

Can high contact resistance be repaired?
Switching 120 mA 10-100 times may clean the contacts.

FAQ 2004-05-14

How do I declassify or sanitize my 54620- or 54640-series oscilloscope?

FAQ 2004-05-05

What is the 8590 series product history?
A complete listing of 8590 series models that include their frequency range, introduction date, discontinuance date, end of support date, and model replacement if applicable.

FAQ 2004-04-06

How can the memory in a 437B Power Meter be erased for security purposes?
This can be done by a sequence of keypresses, or by a sequence of remote commands.

FAQ 2004-02-05

What are the mean time between failure (MTBF) and mean time to repair (MTTR) estimates for the 33120A?
Mean time between failure (MTBF) is 40,000 hours. Mean time to repair (MTTR) is 1.2 hours.

FAQ 2003-06-03

What type of memory is used in the 3499A/B/C?
Flash Memory is used to store 3499A/B/C configuration and set-up.

FAQ 2003-06-02

Is support included with iDEN® FTA for Windows?
Detailed setup and operating instructions will be included with your shipment.

FAQ 2003-01-24

3499A/B/C에서 제공하는 relay-cycle-counters 의 장점은 무엇입니까?

FAQ 2003-01-22

Does the 3488A and/or 3499A/B/C contain batteries?
There are no batteries in the 3488A. For the 3499A/B, please check the firmware revision.

FAQ 2002-09-23

How do I determine the firmware revision of the Keysight 3499A/B/C?
From the front panel, press the "MENU" button, scroll to find the "revision info" in the menu list, press the "ENTER" button.

FAQ 2002-09-23

If a customer wants to increase the number of N2280A/N2281A channels, do they have to buy an additional 3499 mainframe and module?
You can install two of the N2280A and/or N2281A modules in the 3499A mainframe.

FAQ 2002-09-23

The E8404A Enhanced Monitor provides many history features: minimum and maximum values, histograms, operating times, and event logs. What are they ...
The history features provide you with insight into the trends of your test system. Without any programming on your part, your VXI test system will be monitored and information stored.

FAQ 2002-09-17

What is the relay used on the 44470A/D?
The relay supplier and part number for the 44470A is "OMRON" type is G6AK-274P. There is not a Keysight 4 x 4 part number.

FAQ 2002-09-06

8566/68AB: What Is the Part Number for the IF Interconnect Cables?

FAQ 2002-06-27