Here’s the page we think you wanted. See search results instead:

 

Contact an Expert

Technical Support

Electronic Measurement

Support by Product Model Number:

Refine the List

remove all refinements

By Industry/Technology

By Type of Content

76-100 of 3291

Sort:
5 Tips for Optimizing Battery Drain on IoT Devices - Application Note
Optimizing battery run time usually requires the design team to use several different test methods to gain insights that go well beyond just validating battery run time.

Application Note 2018-01-09

PDF PDF 1.52 MB
OTA Setup for 5G TF Beamforming Functional Tests - White Paper
A new approach to over-the-air (OTA) testing of beamforming with multiple angle of arrivals (AoA), specifically, multiple simultaneous downlink beams using existing sub-6 GHz network emulators in conjunction with mmWave RF heads and dual-polarized horns.

Application Note 2018-01-07

PDF PDF 1.12 MB
Using High-Temperature Nanoindentation to Study Mechanical Properties of High-Entropy Alloys (HEA)
Nanoindentation studies of single-phase CoCrFeNi and dual-phase AlCrFeNiTi with faced centered cubic (FCC) and based centered cubic (BCC) structures at room and elevated temperatures

Application Note 2018-01-04

PDF PDF 3.65 MB
Studying Thermal Transitions of Materials Using Quick Scan Technology in Atomic Force Microscopy

Application Note 2017-12-22

PDF PDF 5.03 MB
Optimizing Performance and Cost for Millimeter Wave Signal Analysis - Application Note
This application note discusses recent advances in millimeter wave signal analysis and instrumentation that can be optimized for "just enough" performance versus cost.

Application Note 2017-12-21

PDF PDF 1.61 MB
High-Resolution Mechanical Mapping of High-Entropy Alloys at High Temperatures
Room and high-temperature mechanical properties of single-phase CoCrFeNi and dual-phase AlCrFeNiTi are statistically evaluated using the Keysight's G200 Express Test method.

Application Note 2017-12-21

PDF PDF 5.37 MB
Two-port Measurements and S-Parameters - Aplication Note
An examination of network analyzer two-port measurements and S-parameters

Application Note 2017-12-19

Techniques for Precise Measurement Calibrations in the Field - Application Note
This application note discusses recent advances in VNA calibration and compares measurements made on a FieldFox analyzer using different calibration types for a variety of RF and microwave devices.

Application Note 2017-12-18

8 Hints for Making Better Measurements Using RF Signal Generators
This application note provides 8 hints for improving the accuracy of your measurements using RF signal generators.

Application Note 2017-12-16

PDF PDF
8 Hints for Making Bettter Measurements Using RF Signal Generators - Application Note
This application note provides 8 hints for improving the accuracy of your measurements using RF signal generators.

Application Note 2017-12-16

Understanding the Fundamental Principles of Vector Network Analysis - Application Note 1287-1
This application note explores the fundamental principles of vector network analysis. The discussion includes the common parameters (S-parameters). RF fundamentals such as transmission lines and the Smith chart will also be reviewed.

Application Note 2017-12-14

Understanding the Fundamental Principles of Vector Network Analysis
This application note explores the fundamental principles of vector network analysis. The discussion includes the common parameters (S-parameters). RF fundamentals such as transmission lines and the Smith chart will also be reviewed.

Application Note 2017-12-14

PDF PDF
Practical Temperature Measurements (AN-290)
This application note explores the more common temperature measurement techniques and introduces procedures for improving their accuracy.

Application Note 2017-12-13

Signal Analysis Measurement Fundamentals, Optimize Noise Floor, Resolution Bandwidth, and More
Learn measurement fundamentals to optimize your signal analysis for greater insights.

Application Note 2017-12-13

PDF PDF
Drive Connected, Drive Safe - White Paper
A well-tested eCall/ERA-Glonass system meeting compliance standards at development phase can go on to help save lives and minimize injury aftermath in the event of accidents when cars hit the roads.

Application Note 2017-12-13

PDF PDF 2.33 MB
BER Measurement Using Real-Time Oscilloscope Controlled from M8070A - Application Note
The scope of this application note is to explain the BER measurement procedure using the M8045A pattern generator and DSAZ634A oscilloscope when controlled from M8070A system software.

Application Note 2017-12-13

PDF PDF 6.78 MB
Signal Analysis Measurement Fundamentals, Optimize Noise Floor, Resolution Bandwidth, and More
Learn measurement fundamentals to optimize your signal analysis for greater insights

Application Note 2017-12-13

TS-8989 System Integration Guide - Application Note
In today’s manufacturing environment, floor space is an increasingly invaluable variable in the cost of test equation.

Application Note 2017-12-12

PDF PDF 2.69 MB
Optimize Power Source Integrity Under Large Load Transients - Application Note
This application note discusses several ways to achieve the lowest possible voltage drop by selecting optimal load leads and power supplies and using local bypassing.

Application Note 2017-12-11

PDF PDF 1.57 MB
4G LTE-A in Unlicensed Band – Use Cases and Test Implications - Application Note
4G LTE-A, unlicensed band, Unlicensed Spectrum, uxm, e7515a, LTE-LAA, WLAN, LTE/WLAN Interworking, Carrier Aggregation

Application Note 2017-12-10

Evaluate Lithium Ion Self-Discharge of Cells in a Fraction of the Time Traditionally Required
Determine a cell’s self-discharge by measuring its self-discharge current allowing cells with excessively high self-discharge to be identified and isolated more quickly.

Application Note 2017-12-08

PDF PDF
Evaluate Lithium Ion Self-Discharge of Cells in a Fraction of the Time Traditionally Required
This new way to determine a cell’s self-discharge by measuring its self-discharge current allows cells with excessively high self-discharge to be identified and isolated much quicker vs traditional open-circuit voltage approaches.

Application Note 2017-12-08

PDF PDF 1.57 MB
Network Analyzer Measurement: Filter and Amplifier Examples
Use vector network analyzer measurements to evaluate the performance of active and passive components.

Application Note 2017-12-07

PDF PDF
How to Make the Best Switch Mode Power Supply Measurements - Application Note
Oscilloscope power measurement options provide a quick and easy way to analyze the reliability and efficiency of switching power supplies.

Application Note 2017-12-07

Characterizing Coils in Wireless Charging Systems Using the E4980A/AL LCR Meter
Precision LCR meters characterize the coils in the wireless charging system.

Application Note 2017-12-06

PDF PDF

Previous 1 2 3 4 5 6 7 8 9 10 ... Next