How do I display the mixer conversion loss of M1970 Series or M1971 Series Harmonic Mixer on an X-Series Signal Analyzer?
There is no way to display the conversion loss values from these mixers on screen. There is a hard copy of the conversion loss data supplied with each mixer that can be referenced.

FAQ 2017-06-28

Where can I find manuals for discontinued and obsolete Hewlett-Packard, Agilent and Keysight test equipment?
Most Keysight products have PDF manuals that can be found on product pages. Other vendors also supply old manuals.

FAQ 2014-08-01

How do you clear the 34980A multifunction switch/measure mainframe and modules, L44xxA series LXI switch and control instruments memories?
Please refer to the documents for a comprehensive listing of memory installed into these products.

FAQ 2014-04-07

Will the external mixer Option EXM support the 11974 Series preselected mixers?
There are no plans to support the 11974 Series preselected mixers with the N9030A PXA.

FAQ 2012-10-25

What external mixers will work with my PXA/mmW EXA and how do I order them?
Currently, the N9030A PXA/mmW EXA with Option EXM will work with either the 11970 Series (with the exception of the 11970K) or ) or external mixers from other vendors such a OML Inc. mixers.

FAQ 2012-10-17

Do the ENA provide a probe power connection for active probes?

FAQ 2012-04-17

The Keysight 8761B SPDT Coaxial Switches are not listed in the "Keysight 34945A, L4445A and L4490A/L4491A Configuration Guide". Why?
Due to the 8761B’s internal design the RF path selection is achieved via DC polarity reversal across the coil control terminals. The Keysight 34945A, L4445A and L4490A/L4491A Control Units do not provide a polarity reversal mode. Thus the 8761B cannot be controlled by the 34945A, L4445A and L4490A/L4491A Control Units.

FAQ 2012-01-16

Will there be specification, performance characteristic or usability differences when using the 11970 Series mixers on the PXA?
Yes, there will be several differences when using 11970 Series mixers with the PXA.

FAQ 2011-04-26

How to monitor and scan on alarm with the 34980A?

FAQ 2010-10-04

What is the difference between a standard coaxial connector and precision slotless connector (PSC)?
Precision slotless female contacts are used to reduce the reflection uncertainty at a connector interface. Slotless contacts make electrical connection with the mating male pin without changing the outer diameter of the female center conductor.

FAQ 2010-09-08

What type of switches/attenuators are supported by the 34945A/L4445A Microwave Switch/Attenuator Driver module?

FAQ 2010-09-08

Why do I get verification error upon reset with single channel pulsed switches and Y1151A distribution board?
On this particular distribution board...

FAQ 2010-06-30

Can the measurements taken be read from the 34980 Data Acquisition Front Panel?
No

FAQ 2010-05-14

Can I mix 34980As and 34970As in the same configuration?
You can have a combination of one 34980A and one or two 34970As in a configuration.

FAQ 2010-05-05

How can I control the 34980A internal DMM using the IVI-C Dmm class in cooperation with the 34980A IVI driver?
Please download from the link for the document on how to control the internal DMM using IVI-C Dmm class in cooperation with the 34980A IVI driver.

FAQ 2009-12-02

On the 83050A microwave amplifier, is there any internal circuitry to protect the amplifier from damage due to an accidental polarity reversal conn...

FAQ 2009-03-13

Does the Keysight 34951A D/A Converter require a Settling Time for Generated AC Signals?
Yes. Settling time depends on the number of points of the AC waveform and the type of load.

FAQ 2007-11-18

Can the 34980A automatically open or close Switches based on Alarm Conditions?
Yes. The 34980A can use the Sequence feature to allow the instrument to automatically open or close switches in the event of an alarm.

FAQ 2007-01-11

Can the measurements be displayed on the 34980 front-panel?
No.

FAQ 2007-01-10

What is the typical 1 dB compression point for the Keysight N9397C solid state switch?
The typical, non-warranted, non-specified, 1dB gain compression point is +26 dBm at 2.0 GHz.

FAQ 2006-11-05

What is the proper connection when connecting a 7 mm (APC-7) connector to my 8753ES 7 mm test port?

FAQ 2006-10-25