Can a CalPod system be used with the N1500A software?
No, the CalPod and N1500A Software are not compatible.

FAQ 2017-06-28

35670A DSA的哪些選項可在現場安裝,哪些選項必須在是德安裝?

FAQ 2014-05-01

我在哪裡可以找到過時的HP測試儀器的使用手冊?
有一些公司可能還會提供這些使用手冊…

FAQ 2013-05-29

是德推薦何種資源協助瞭解正確的阻抗量測技術?
是德推薦《Keysight Technologies Impedance Measurement Handbook》,本書涵蓋了與阻抗基礎原理相關的基本資訊。本手冊中的主題包括:阻抗量測;量測方法;夾具與接線;量測錯誤與補償。

FAQ 2012-07-17

各種 Keysight 85070E 選項的等同產品編號為何?

FAQ 2012-05-10

Why is a negative D value sometimes displayed when a furnished PTFE plate is measured with the 16453A?
When resistance value of Short compensation data is too large, measured D value is overcompensated for the Short resistance and results in a negative value

FAQ 2012-04-08

85070E-020 高溫探棒搭配不同的分析儀一起使用時,是否有不同的最小樣品厚度建議值?
沒有。 Keysight 85070E選項020的最小樣品建議厚度,同樣適用於向量網路分析儀與RF-IV阻抗分析儀。

FAQ 2012-02-20

85070E/85071E: What Are the Dimensions of the 7mm and 3.5mm Airlines?

FAQ 2011-11-07

85070D/85071D: Microwave Materials Measurements With a Network Analyzer
The necessary items include a network analyzer, a probe or sample holder, and measurement software.

FAQ 2011-10-03

Why is permeability measurement result unstable when a low permeability magnetic material or a thin magnetic material is measured with the 16454A?
It is because the impedance of the magnetic material inserted into the 16454A is too low for the impedance analyzer to measure it accurately.

FAQ 2011-06-07

What is the possible cause of the difference when the permittivity measured with the 16453A is different from the value previously obtained?
Most likely cause of the measurement discrepancy or drift is insufficient electrode pressure due to improper pressure adjustment.

FAQ 2011-06-07

Why is Rp or G measurement value unstable when pure water is measured with the 16452A?
There are two conceivable causes of unstable measurement results. One of primary causes is a change in temperature of pure water sample measured. The other is a slight pollution which resides on the electrode surfaces.

FAQ 2010-07-02

Can I have criteria or a list of non-applicable liquid materials for the 16452A?
Avoid measuring acidic, alkaline and ionic materials with the 16452A.

FAQ 2010-07-02

E4991A-002/4291A/B-002 with 16454A: Why is impedance measurement value different from the value calculated from permeability?
Error compensation in the permeability measurement firmware produces the difference between measured impedance and permeability.

FAQ 2010-07-02

How wide range of resistivity can the 4339B measure when used with the 16008B?
The 4339B can measure surface resistivity up to 7 x 1017 Ω and volume resistivity up to 8 x 1018 Ω-cm, but it depends on the electrodes of the 16008B used.

FAQ 2010-07-02

How can I connect a test fixture to the measurement terminals of the E4980A when the stopper at the rear of the fixture disturbs the connection?
Remove the stopper from the test fixture by removing a screw at the center of the plastic stopper. Otherwise, remove the front rubber guide from the E4980A.

FAQ 2010-07-02

我如何清除 35670A 記憶體內的資料?
我如何清除 35670A 記憶體內的資料?

FAQ 2010-05-17

在未使用 Keysight 16453A 或 16454A 的狀況下,E4991A 選項 002 是否可以量測電容率與磁導率?
不能。使用 Keysight E4991A選項002來測量電容率與磁導率時,需要同時使用 Keysight 16453A 或 16454A。

FAQ 2010-04-29

搭配使用 Keysight 4294A 和 16451B時,要如何執行負載補償?
可以使用 Keysight 16451B平行電極板的空氣介電電容作為負載元件,執行負載補償。

FAQ 2010-04-29

8507x Series Service and Support

FAQ 2010-01-11

搭配 Keysight 85070E 介電探棒套件使用的各種探棒,有什麼樣的頻率限制?理由何在?
Keysight 85070E 介電探棒選項 020、030 與 050,透過 3 GHz 的 Keysight E4991A 阻抗分析儀,可擁有最大頻率。

FAQ 2009-08-11

85070E/85071E: What Are the Part Numbers for 7mm and 3.5mm Airlines for Materials Measurements?
7mm airline 85051-60010 3.5mm airline 85053-60008

FAQ 2009-02-17

Does 85070E and 85071E software run on Windows Vista?
Windows Vista must be configured to allow the 85070E and 85071E to write files to the Program Files folder.

FAQ 2009-02-05

There are 4 types of spacers for the 16452A. Is there any criterion for selecting the spacer?
There is no specific criterion for the selection except that the 1.3 mm spacer is required for the short compensation.

FAQ 2009-01-12

Is the collet (center contact) of the 16454A identical to that of the 42942A (part number 1250-0907)?
Yes, When replacing the collet (center contact) of the 16454A, you can use the same part (part number 1250-0907) as that used in the 42942A.

FAQ 2009-01-12