Agilent IntuiLink Multimeter offers the following capabilities:

- Save and restore Instrument settings.

- Insert measurements into Excel and Word

- Log Measurements at predetermined interval into Excel.

- General Purpose 3494A ActiveX(TM) Custom Control for easy programming.

- Programming examples included for several popular
programming environments.


Installation requirements
--------------------------
Minimum Operating System requirements:
* Windows 95/98, or
* Windows NT 4.0 (with Service Pack 4 or greater, obtain at www.microsoft.com), or
* Windows 2000
* Windows XP

Minimum MS Office application requirements:
* Microsoft Office 97 (Word or Excel) or
* Microsoft Office 2000
* Microsoft Office XP


Supported Instruments
---------------------
34401A, 34410A, 34411A, 34420A


Complementary Start-Up Assistance
---------------------------------
Agilent Technologies will provide Start-Up Assistance at
no charge to resolve questions relating to the installation,
operation, and use of this software product. Start-Up
Assistance is available to help you install the software
on your PC, establish communication with a compatible
instrument, and answer questions relating to the
functionality of the software components provided by Agilent.
Start-Up Assistance does not support requests to modify
or enhance the functionality of the software. For services
not covered by Start-Up Assistance, you may be referred
to fee-based services for advanced assistance.

Agilent will make reasonable efforts to respond to each customer
request for Start-Up Assistance within two working days,
but is under no obligation to respond within a prescribed
time frame. Requests for Start-Up Assistance are handled
in the order in which they were received. Agilent will make
reasonable efforts to solve customer problems, but cannot
guarantee success.

Agilent reserves the right to terminate Start-Up
Assistance at any time without notice.

Agilent VEE and Other Instrumentation System Drivers
----------------------------------------------------
34401A Plug and Play instrument drivers are in the
\drivers directory on the Agilent IntuiLink CD-ROM.

Agilent Multimeter Manuals
-----------------------------------------
The Agilent 34401A and 34420A manuals are available in
Adobe(R) Acrobat(R) format (.PDF) in the \manuals directory
on the Agilent IntuiLink CD-ROM. Also included in this
directory is the Acrobat Reader program for viewing the
.PDF files.

Word Toolbar Error 'Compile error'
----------------------------------
The toolbar in Word requires the installation of the
'Office Graph Chart'. This is normally installed with Office,
but may not be installed with Office for Small Businesses.
Use the Office CD to install the the Office Chart if you
have this error.

Agilent IntuiLink On-Line Help System
----------------------------------------
During installation, the appropriate on-line help system
language version is installed based on the operating system
detected on the PC. In addition, the language can be changed
from the About box in Excel and Word.

The help system is also available in Adobe(R) Acrobat(R)
format (.PDF) in the \pdf_help directory on the
Agilent IntuiLink CD-ROM. See the \manuals\adobe directory
on the CD-ROM to download the Acrobat Reader program for
viewing the .PDF files.


Frequently-Asked Questions
--------------------------
A list of Frequently-Asked Questions (FAQs) for
Agilent IntuiLink is available in the \faqs directory
on the Agilent IntuiLink CD-ROM (in .txt format).

For the latest list of FAQs, go to the Agilent web site
at www.tm.agilent.com and click
on "Technical Support".

Windows 95 and Agilent SICL F.01.01 and Earlier
-----------------------------------------------
Windows 95 32-bit Agilent SICL and VISA versions F.01.01 and
earlier will, by default, yield the CPU during I/O operations.
Agilent IntuiLink requires that the CPU not be yielded during
I/O operations. This is the default operation for Agilent SICL
versions F.01.02 and later.

For Agilent SICL versions F.01.01 and earlier, add a registry entry
which instructs SICL not to yield during I/O operations.
Add the following key:

"HKLM/Software/Hewlett-Packard/SICL/CurrentVersion/Options"

Under this key, add a string entry "Yield" with a value "false".

Windows 95 and Agilent SICL 'Options' Menu
------------------------------------------
In the I/O Configuration program, the following selections
are available in the 'Options' menu:

SICL Yield (Win95 only)
- False (Default) * SICL does not yield the CPU during I/O
- True * SICL yields the CPU during I/O

Note: SICL Yield must be 'False' for proper operation of some
Plug&Play drivers. This will prevent a potential deadlock
from within a Windows message handler.

LabVIEW Version 5.1 Required
----------------------------
The Agilent General Purpose I/O ActiveX Control will not work properly
in versions of LabVIEW prior to version 5.1.


Troubleshooting Tips and Technical Support Information
------------------------------------------------------
For troubleshooting tips and technical support information,
first refer to the Agilent IntuiLink Multimeter on-line help system.
For further assistance, contact the Agilent IntuiLink Technical
Support personnel at the support numbers listed below:

Country Telephone Fax E-Mail
------------- ----------------- ----------------- --------------------------------
Australia 1 800 629 485 03 9272 0749 [email protected]
Austria (01) 25000-7006 (01) 25000-6558 [email protected]
Bangladesh 880-2-9130480 880-2-871034 [email protected]
Belgium 32-2-778.34.13 32-2-778.34.14 ---
Brazil (+55 11)7297-8600 (+55 11)7297-8171 [email protected]
Canada 877 894-4414 (905) 206-4120 ---
China 86 10 65645261 86 10 65668250 [email protected]
Czech Rep +420 2 333 21 707 +420 2 333 20 672 [email protected]
Denmark 45 99-15-15 --- ---
Europe --- 31 20 547 7700 [email protected]
Finland 358-10-885 2100 --- ---
France 01 69 29 4114 01 69 82 6535 ---
Germany --- (0180) 524-6335 [email protected]
Hong Kong (852) 2599 7889 (852) 2506 9256 ---
Hungary (36) 1 382 6006 (36) 1 382 6001 ---
India 011-6906215 011-6926063 [email protected]
Indonesia 62-21 3800902 62-21 3518814 [email protected]
Ireland 01 205 4538 --- ---
Israel 972-3-5380570 972-3-5380525 [email protected]
Italy 02 9260 8484 02 9210 4069 [email protected]
Japan 81-426-56-7832 81-426-56-7840 [email protected]
Korea 82/2-769-0800 82/2-784-5839 [email protected]
Luxembourg 32-2-778.59.50 32-2-778.59.51 ---
Malaysia 1-800-88-8848 603-298 9157 [email protected]
Mexico (5) 258-4209 --- ---
Netherlands 020 547 6669 020 547 7765 [email protected]
New Zealand 0800 738 378 04 802 6881 [email protected]
Norway +47 2273 5759 +47 2273 5629 [email protected]
Pakistan 92-51-818-959 92-51-816-190 [email protected]
Philippines (632) 814-1066 (632) 811-1080 [email protected]
Poland +48 (022) 6084554 +48 (022) 6084555 ---
Portugal (351/1) 482 8500 (351/1) 444-7077 ---
Russia +7-095-797 3628 +7-095-916 9848 [email protected]
Singapore 3744242 2754709 [email protected]
South Africa +27-11-444 8010 +27-11-444-8511 [email protected]
Spain 34 91 631.13.23 34 91 631.14.69 ---
Sri Lanka 94-74-717 701 941-504 340 [email protected]
Sweden (08) 444-2277 46 8 444-2525 ---
Switzerland --- (0180) 524-6335 [email protected]
Taiwan 0800-47866 --- ---
Thailand (02) 661-5900 (02) 661-6420 ---
Turkey (90/312) 468 8770 (90/312) 468 8778 [email protected]
United Kingdom 01344-366666 --- ---
United States 800 452 4844 888-900-8921 ---
Viet Nam 844-8-229808 844-8-229553 [email protected]

NOTE: In all other countries, please contact your local Agilent Representative
or go to the Agilent web site at www.tm.agilent.com.



© Agilent 2000-2006