Keysight IO Libraries Suite 2017

Keysight IO Libraries Suite 2017 began the next generation of the former Agilent IO Libraries Suite, the libraries and tools you've come to rely on to speed up connection and control of your instruments. IO Libraries Suite 2017 completes the implementation of the Keysight name in file paths, Windows service names, etc. Agilent’s Electronic Measurement Group became Keysight Technologies in 2014; for more information, see http://www.keysight.com.

Table of Contents


What is the Keysight IO Libraries Suite? top

The Keysight IO Libraries Suite is a collection of libraries and utility programs. The IO libraries (SICL, VISA, VISA.NET and VISA COM) enable instrument communication for a variety of development environments (Keysight VEE Pro, Microsoft Visual Studio, etc.) that are compatible with GPIB, USB, LAN, RS-232, PXI, AXIe, and VXI test instruments from a variety of manufacturers. Several utility programs help you quickly and easily connect your instruments to your PC.

Establishing communication between your instruments and your PC is as easy as 1, 2, 3:

  1. Install the IO Libraries Suite: Get all the software you need to connect instruments to your PC via GPIB, USB, LAN, and other standard interfaces.
  2. Install Instrument Software and Connect Your Instruments: Install any software and drivers that came with your instruments. Connect cables and apply power.
  3. Run Keysight Connection Expert to Identify and Communicate with Instruments: See connected instruments, send commands to your instruments, and make configuration settings.

If you received two disks with your Keysight product, install the IO Libraries Suite first. Then browse the second disk to find instrument drivers, documentation, and other application software, depending on the product you have purchased.

System Requirements for Keysight IO Libraries Suite 2017 top

The following table lists the system configurations that Keysight tested IO Libraries Suite 2017 on and that are therefore guaranteed to work. In general, any x86 or x64 (except Itanium) processor should work but there may be a decrease in performance.

Operating System Windows 7 SP1 (32-bit and 64-bit) Starter, Home Basic, Home Premium, Professional, Ultimate, Enterprise Windows 8 and Windows 8.1 (32-bit and 64-bit), including Windows 8/8.1 Core, Windows 8 /8.1 Pro, and Windows 8/8.1 Enterprise Windows 10 (32-bit and 64-bit), including Windows 10 Home, Windows 10 Pro, Windows 10 Enterprise, and Windows 10 Anniversary Update Windows Server 2008 R2 SP1 (64-bit) Standard and Enterprise Windows Server 2012 (64-bit) Standard
Processor Speed 1 Ghz 32-bit (x86), 1 GHz 64-bit (x64), no support for Itanium64 1 Ghz 32-bit (x86), 1 GHz 64-bit (x64), no support for Itanium64 or Windows 8 RT 1 Ghz 32-bit (x86), 1 GHz 64-bit (x64), no support for Itanium64 or Windows 10 RT 1.4 GHz (x64 processor) or 1.3 GHz (Dual Core), no support for Itanium64 1.4 GHz (x64 processor) or 1.3 GHz (Dual Core), no support for Itanium64
Available Memory 1 GB minimum1 1 GB minimum1 1 GB minimum1 1 GB minimum1 1 GB minimum1
Available Disk Space2

1.5 GB available hard disk space, includes:

·1 GB available for Microsoft .NET Framework 4.6

·100 MB for Keysight IO Libraries Suite

2.5 GB available hard disk space, includes:

·2 GB available for Microsoft .NET Framework 3.5 and 4.6

·100 MB for Keysight IO Libraries Suite

2.5 GB available hard disk space, includes:

·2 GB available for Microsoft .NET Framework 3.5 and 4.6

·100 MB for Keysight IO Libraries Suite

1.5 GB available hard disk space, includes:

·1 GB available for Microsoft .NET Framework 4.6

·100 MB for Keysight IO Libraries Suite

2.5 GB available hard disk space, includes:

·2 GB available for Microsoft .NET Framework 3.5 and 4.6

·100 MB for Keysight IO Libraries Suite

Display Minimum of 1024 x 768, 96 or 120 DPI Minimum of 1024 x 768, 96 or 120 DPI Minimum of 1024 x 768, 96 or 120 DPI Minimum of 1024 x 768, 96 or 120 DPI Minimum of 1024 x 768, 96 or 120 DPI

Browser: Use a supported version of Internet Explorer; see http://support.microsoft.com/kb/969393.

1 On older PCs with minimum RAM, installation can take a long time when installing the IO Libraries Suite and the .NET Framework.

2 Because of the installation procedure, less disk space may be required for operation than is required for installation. The amount of space listed above is required for installation.

Other Requirements

Windows version 8.1 and Windows Server version 2012 R2 require Windows update 2919355 before Keysight IO Libraries can be properly installed.

Who is licensed to install IO Libraries Suite?

See the License Grant at the end of this file to determine whether you are licensed to install this software.

What if I need support for an older operating system?

It is generally best to use the current version of the IO Libraries Suite. This version will support the newest interfaces and operating systems, and will have the most advanced features. However, you may need to install an earlier version of the IO Libraries Suite to support an older interface or operating system. Refer to http://www.keysight.com/find/iosuite to locate the version you need.


Installing the Software top

To install Keysight IO Libraries Suite:

First, disconnect any USB instruments, USB/GPIB converters, PXI and AXIe chassis, and FireWire (IEEE 1394)/VXI interfaces that are connected to your PC.

Shut down all other applications that are running on the PC.

If you have the IO Libraries disk in your CD/DVD drive:

  1. Open Windows File Explorer and browse the CD/DVD drive.
  2. Browse to the Autorun folder and double-click to execute auto.exe.

If you are downloading Keysight IO Libraries Suite from the Web:

  1. Go to http://www.keysight.com/find/iosuite.
  2. Download the IO Libraries Suite self-extracting zip file (*.exe) to any location on your hard disk.
  3. Double-click the .exe file to extract all files and start the installation process. Follow the instructions as prompted during the installation.

You can select either a Typical or a Custom installation. In most cases, select Typical installation to install the IO Libraries Suite using the recommended settings. Select the Custom installation to:

After the installation is complete, re-connect any devices that you disconnected prior to installing.


What's New in Keysight IO Libraries Suite 2017?

top

IO Libraries Suite 2017 provides several enhancements, including:

Keysight IO Libraries Suite 2017 marked a significant update in the architecture of the IO Libraries Suite infrastructure, as well as an all-new Connection Expert. To learn more about those changes, see the Transition Guide in the IO Libraries Suite Help. To find this help, click the IO Control icon in the Windows notification area, then select Documentation > IO Libraries Suite Help.

Note: The IO Libraries Suite GPIB auto-scan feature is incompatible with certain instruments, including some Keysight 34980As and 34410As; in some cases, compatibility depends on the version of firmware on your instrument. If IO Libraries Suite detects an incompatible instrument on a GPIB interface, it will automatically turn off auto-scan for that GPIB interface.

In addition, some older instruments do not respond correctly to the SCPI identification query, *IDN? These instruments may experience problems when queried by the IO Libraries Suite. After two failures, IO Libraries Suite will stop sending *IDN? to that instrument until the next reboot or reconnect. You can prevent *IDN? from ever being sent to a specific instrument by manually adding the instrument and turning off its auto-identification property.

For more information on the auto-scan and auto-discovery features, click the IO Control icon in the Windows notification area, then select Documentation > IO Libraries Suite Help. Search for "auto-scan" or "auto-discover" in the help file. For up-to-date information about compatibility issues and solutions, visit www.keysight.com/find/iosuitecompatibility.


Upgrading from Earlier Versions of IO Libraries Suite

top

There are no issues upgrading from IO Libraries Suite revisions 17.0, 17.1, 17.2, or 17.3 to revision 2017.

When you upgrade from versions prior to IO Libraries Suite 17.0, in general, your configuration is retained. However, you may see some changes in your configuration and some instrument properties may be lost. For detailed information and workarounds, see Upgrading from Earlier Versions in the IO Libraries Suite Help. To find this help, click the IO Control in the Windows notification area, then select Documentation > IO Libraries Suite Help.


Known Issues

top

Uninstalling the Software

top

Use the Windows Control Panel > Programs & Features to remove the Keysight IO Libraries Suite. Do not delete files directly. To uninstall or modify the Keysight IO Libraries Suite, select Keysight IO Libraries Suite from the list of installed programs.

Removing the IO Libraries Suite does not delete the standard VISA directory, standard VISA COM files, standard VISA.NET files, standard IVI (Interchangeable Virtual Instrument Foundation) files, and IVI Shared Components. This is because there is no reliable way for the IO Libraries Suite uninstaller to be sure that no other installed product (whether from Keysight or another vendor) is using these files and directories.


License Grant

top

Keysight grants you a non-exclusive license of the Software at no charge pursuant to the terms of the License Agreement. The License Agreement is displayed when you install the software and is available in the IO Libraries Suite Online Help. You may download the Software, and store or run the Software for internal use and purposes in accordance with this Agreement and the documentation provided with the Software. Such documentation may include license terms provided by Keysight's third party suppliers, which will apply to the use of the Software and take precedence over these license terms. In the absence of documentation specifying the applicable license, you may store or run the Software on your PC(s) and instrument(s). If the Software is otherwise licensed for concurrent or network use, you may not allow more than the maximum number of authorized users to access and use the Software concurrently.


PCIe® and PCI EXPRESS® are US registered trademarks and/or service marks of PCI-SIG.

© Keysight Technologies 1983-2017

Keysight IO Libraries Suite 2017