UXR1102A Infiniium UXR-Series Oscilloscope: 110 GHz, 2 Channels
Sold By: |
|
---|
Key Features and Functions
- 110 GHz bandwidth
- 2 full-bandwidth channels
- 256 GSa/s sample rate on all channels
- Up to 2 Gpts of memory
- 10 bit ADC
- Optional calibration module for on-site self-calibration
- Ruggedized 1mm inputs with new AutoProbe III interface
- High-speed SDA and Clock Recovery included
- User Defined functions included
- Indium Phosphide (InP) process and chipsets
Every spec verified, adjustments included
Data Sheet and Key Documents
To view all: Visit Document Library
What's Included
- USB Keyboard and Mouse
- 1 mm Ruggedized Female to 1 mm Female Adaptor
- Wrench - 2 mm thick, dual-ended, fits 6mm and 7mm
- Torque Wrench - 4 in-lb, 6 mm-open end
- Torque Wrench - 8 in-lb, 5/16 Inch
- Double-ended Torque Wrench - 4 and 10 in-lb, 14 mm-open end
- Adapter-Coaxial Straight 2.92 mm Jack to 2.40 mm Jack 50-Ohm 40GHz
- 1 mm Ruggedized Female to 2.92 mm Female Connector Saver Adapter
- ESD Mat with Wrist Strap and Cord
- Heel Ground Strap
-
Infiniium UXR-Series Oscilloscopes -
Introduction of Infiniium UXR-Series Oscilloscopes
Software for this Product
UXR-Series Analysis Applications
UXR-Series Analysis Applications
- Full offline capability allows you to test from simulation through silicon debug
- VSA software enables analysis of your toughest RF problems
- Connect up to 10 oscilloscopes to achieve 40 channels of acquisition in a single timebase
UXR-Series Protocol Applications
Simplify the debugging of your design
- Decode the protocol packets of more than 20 high-speed serial buses
- Packets are displayed on scope waveform and listing windows, which are time-correlated
- Debug and find the root cause of issues whether it is physical or protocol layer related
UXR-Series Compliance Applications
Get deep technical expertise
- Test to the exact specifications of each technology standard
- Compliance software packages are certified by Keysight experts
- Have assurance that your products will pass standards
Frequently Bought Together
N2852A AutoProbe II to AutoProbe III interface adapter
- AutoProbe II to AutoProbe III interface adapter
- Enables use of AutoProbe II probing portfolio on UXR-Series oscilloscopes
- Allows cascaded use with InfiniiMax AutoProbe II adapters (N5442A or N5449A)
Infiniium UXR Oscilloscope Calibration Modules
Infiniium UXR Real-Time Oscilloscope Calibration Modules
- Enables full factory quality calibration
- Generates known signals that are calibrated to National Institute of Standards and Technology
- Three different models to interface with either the 1.0, 1.85, or 3.5 mm UXR front-end technology
* Prices for: United States. Prices are subject to change without notice. Prices shown are Manufacturer's Suggested Retail Prices (MSRP). Prices shown are exclusive of taxes.