Here’s the page we think you wanted. See search results instead:

 

Contact an Expert

CalPod Calibration Refresh Module

Keysight provides a new and unique way to quickly and easily refresh a calibration at the push of a button, without removing the DUT, and without the physical connection of standards.

Have you ever wondered right before making a measurement, “is the calibration still valid?” In the middle of a very long testing sequence, or when making a critical measurement is not the time to be concerned about whether or not the calibration is still valid!

CalPod calibration refresh modules are in-situ devices that can remove the effects of environmental variations in test cables, connectors, adaptors, switch matrices, to re-establish a valid calibration at the measurement plane, assuring your device’s performance is not affected by these other environmental variations.

For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.

Compare All CalPod Calibration Refresh Modules (11)

  • 85523B CalPod Controller 85523B CalPod Controller (1) 

    85523B CalPod Controller

    • Used with the PNA family of VNA products to control the CalPod calibration refresh modules

  • 85542B 40 GHz TVAC CalPod 85542B 40 GHz TVAC CalPod (1) 

    85542B 40 GHz TVAC CalPod

    • EProvides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range

  • 85541B 40 GHz Temp Characterized CalPod 85541B 40 GHz Temp Characterized CalPod (1) 

    85541B 40 GHz Temp Characterized CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range

  • 85540B 40 GHz Standard CalPod 85540B 40 GHz Standard CalPod (1) 

    85540B 40 GHz Standard CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards

  • 85532B 20 GHz TVAC CalPod 85532B 20 GHz TVAC CalPod (1) 

    85532B 20 GHz TVAC CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range
       

  • 85531B 20 GHz Temp Characterized CalPod 85531B 20 GHz Temp Characterized CalPod (1) 

    85531B 20 GHz Temp Characterized CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range
       

  • 85530B 20 GHz Ambient Temperature CalPod Module 85530B 20 GHz Ambient Temperature CalPod Module (1) 

    85530B 20 GHz Ambient Temperature CalPod Module

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
       

  • 85556A 1 x 12 Fan Out Cable Splitter 85556A 1 x 12 Fan Out Cable Splitter (1) 

    85556A 1 x 12 Fan Out Cable Splitter

    Used to expand the number of CalPod modules that can be controlled by one 85523A/B CalPod controller

    Normally placed inside of a thermal or thermal-vacuum chamber

    Allows one port of the 85523A/B CalPod controller to control up to 12 CalPod modules
     

  • 85554A 10 Meter CalPod Drive Cable Extension 85554A 10 Meter CalPod Drive Cable Extension (1) 

    85554A 10 Meter CalPod Drive Cable Extension

    • Used to extend the length of the CalPod control cables
    • This cable is often used to route CalPod control signals through DC bulkhead connectors used in thermal-vacuum chambers

  • 85553A 2 Meter 40 GHz CalPod Drive Cable 85553A 2 Meter 40 GHz CalPod Drive Cable (1) 

    85553A 2 Meter 40 GHz CalPod Drive Cable

    • Used to connect the 40 GHz CalPod modules to the 85523A CalPod controller
    • Also used to connect the 40 GHz CalPod modules to the 85556A control cable splitter
    • Carries ± 15 VDC and 60 mA