Here’s the page we think you wanted. See search results instead:

 

Contact an Expert

CalPod Calibration Refresh Module

Keysight provides a new and unique way to quickly and easily refresh a calibration at the push of a button, without removing the DUT, and without the physical connection of standards.

Have you ever wondered right before making a measurement, “is the calibration still valid?” In the middle of a very long testing sequence, or when making a critical measurement is not the time to be concerned about whether or not the calibration is still valid!

CalPod calibration refresh modules are in-situ devices that can remove the effects of environmental variations in test cables, connectors, adaptors, switch matrices, to re-establish a valid calibration at the measurement plane, assuring your device’s performance is not affected by these other environmental variations.
 

Compare All CalPod Calibration Refresh Modules (11)

  • 85523B CalPod Controller 85523B CalPod Controller (1) 

    85523B CalPod Controller

    • Used with the PNA family of VNA products to control the CalPod calibration refresh modules

  • 85542A 40 GHz TVAC CalPod 85542A 40 GHz TVAC CalPod (1) 

    85542A 40 GHz TVAC CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range

  • 85541A 40 GHz Temp Characterized CalPod 85541A 40 GHz Temp Characterized CalPod (1) 

    85541A 40 GHz Temp Characterized CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range

  • 85540A 40 GHz Standard CalPod 85540A 40 GHz Standard CalPod (1) 

    85540A 40 GHz Standard CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards

  • 85532B 20 GHz TVAC CalPod 85532B 20 GHz TVAC CalPod (1) 

    85532B 20 GHz TVAC CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range
       

  • 85531B 20 GHz Temp Characterized CalPod 85531B 20 GHz Temp Characterized CalPod (1) 

    85531B 20 GHz Temp Characterized CalPod

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
    • Accurate re-correction capabilities over a -30 to +80 °C temperature range
       

  • 85530B 20 GHz Ambient Temperature CalPod Module 85530B 20 GHz Ambient Temperature CalPod Module (1) 

    85530B 20 GHz Ambient Temperature CalPod Module

    • Provides in-situ calibration refresh capability
    • Does not require removing the DUT
    • Does not require re-connecting calibration standards
       

  • 85556A 1 x 12 Fan Out Cable Splitter 85556A 1 x 12 Fan Out Cable Splitter (1) 

    85556A 1 x 12 Fan Out Cable Splitter

    • Used to expand the number of CalPod modules that can be controlled by one 85523A CalPod controller
    • Normally placed inside of a thermal or thermal-vacuum chamber
    • Allows one port of the 85523A CalPod controller to control up to 12 CalPod modules
       

  • 85554A 10 Meter CalPod Drive Cable Extension 85554A 10 Meter CalPod Drive Cable Extension (1) 

    85554A 10 Meter CalPod Drive Cable Extension

    • Used to extend the length of the CalPod control cables
    • This cable is often used to route CalPod control signals through DC bulkhead connectors used in thermal-vacuum chambers

  • 85553A 2 Meter 40 GHz CalPod Drive Cable 85553A 2 Meter 40 GHz CalPod Drive Cable (1) 

    85553A 2 Meter 40 GHz CalPod Drive Cable

    • Used to connect the 40 GHz CalPod modules to the 85523A CalPod controller
    • Also used to connect the 40 GHz CalPod modules to the 85556A control cable splitter
    • Carries ± 15 VDC and 60 mA