Here’s the page we think you wanted. See search results instead:

 

Contact an Expert

Data Acquisition – DAQ

DAQ System – More than 25 years of Leadership

Keysight has provided data acquisition (DAQ) and switching solutions for more than 25 years. We provide data acquisition solutions for electrical, physical, mechanical, acoustic and signal routing applications up to 50GHz.

Compare data acquisition (DAQ) switch platforms

Define a switching solution with switches, controllers and accessories.

  • Get the Best Value with high quality switching and measurements in compact, cost effective solutions
  • Use on Industry Standards with modular LXI and VXI solutions
  • Use the Keysight’s Application Software to collect, analyze and present your data real-time

Check out Keysight next-generation multi-channel data acquisition (DAQ) system — sample more signals, faster!

1-25 of 78

Sort:
Effective Monitoring and Streamline Testing Using a DAQ - White Paper
Learn how to choose the DAQ system that will work best for your project or environment, whether it is a centralized or distributed DAQ configuration setup. Use the DAQ switching control system to streamline your test process.

Application Note 2019-10-19

PDF PDF 3.11 MB
34980A Measurements Made Easy
This document includes examples with the few steps needed to make measurements using the 34980A's 1) front panel, 2) built-in web interface, and 3) Command Expert software.

Application Note 2019-10-04

PDF PDF 5.32 MB
Recognizing and Reducing Data Acquisition Switching Transients - White Paper
Low impedance sources can produce large and fast current transients when switching; creating problems with adjacent channels, transients in the ground circuit that upset digital logic connected to the DUT, or causing the switch unit to reset or hang. This application note describes several techniques to reduce these switching transients.

Application Note 2019-09-27

Conquer IoT Test Challenges for ZigBee IoT Products
This paper discusses common difficulties in manufacturing test of Wireless IoT devices and how the Keysight ZA0060A solves them inexpensively.

Application Note 2019-04-25

PDF PDF 711 KB
Power Handling Capability of Electromechanical Switches
This application note discusses the power handling of the hot switching and cold switching of EM switches.

Application Note 2019-02-13

Comparisons: DAQ970A to 34970A and 34972A Data Acquisition System - White Paper
This paper provides a comparison of the next generation DAQ970A and, the 34970A/34972A Data Acquisition Systems.

Application Note 2018-10-30

Fast Thermal Characterization and Testing Your Electronic Devices - White Paper
Fast thermal characterization and testing gives you the advantage of quick and qualitative insight into your products’ characteristics, the ability to troubleshoot and fine-tune the performance, and the capability to perform additional iterative testing. Learn how to predict and preview operating temperature performance of your product. Learn how to use a DAQ data acquisition system as a data logger to make temperature measurements on your product.

Application Note 2018-09-21

Temperature Data Logging: Making the right choice with a Data Acquisition System - White Paper
Consider using a DAQ as a temperature data logger due to its flexibility to make multiple temperature measurements, choice of sensor types with high accuracy, the ability to measure other signal types, easy to configure and automate testing without programming.

Application Note 2018-08-29

Make Better AC RMS Measurements with Your Digital Multimeter - Application Note
Learn about the complexity of ac rms measurements and how to deal with them

Application Note 2018-08-17

Accurately measure path loss for over the air transmitter and receiver measurements
This application note describes how to improve the accuracy of the Keysight X8711A by properly measuring path loss and applying the right system offset in the test plan.

Application Note 2018-08-16

PDF PDF 981 KB
4 Things to Consider When Using a DAQ as a Data Logger
Product designs keep increasing in complexity. So do product test requirements. Learn how to improve test development cycle time, choose the right setup to optimize your test time, and improve the accuracy of your data acquisition test system.

Application Note 2018-08-07

How to Optimize Measurement Speed of Your DAQ - White Paper
This white paper will show you how to optimize the measurement speed of a midrange DAQ system, Keysight’s DAQ970A system, to meet most of your design validation tests. You will learn how to choose the right hardware and configuration settings that will help you optimize your measurement and transactional speed.

Application Note 2018-07-17

Testing Next Generation AC Controller with BLE Radio Technology - Application Brief
How an air conditioner manufacturer tested their next generation controller with Bluetooth Low Energy radio technology.

Application Note 2018-04-11

PDF PDF 695 KB
Achieve Accurate Two Wire Resistance Measurements with the Keysight 34923A and 34924A Multiplexers -
This application note provides an overview of how to make an accurate two-wire resistance measurement with the Keysight 34980A and a multiplexer.

Application Note 2018-03-20

Practical Temperature Measurements (AN-290)
This application note explores the more common temperature measurement techniques and introduces procedures for improving their accuracy.

Application Note 2017-12-13

Achieve Accurate Resistance Measurements with the Keysight 34980A Multifunction Switch Measure Unit
This application note provides an overview of how to make an accurate 2-wire, 3-wire and 4-wire resistance measurements with the Keysight 34980A

Application Note 2017-12-05

Temperature Measurement Solution for Solar Cell and Module Testing - Application Note
This application note highlights key products that can be used to help you effectively and efficiently test solar cells and solar modules, and ensure that they are able to perform optimally.

Application Note 2017-10-25

Using BenchVue to Create and Execute Scan Lists on 3497xA Data Acquisition Units - Application Note
Lean how Keysight's BenchVue software can be used with 3497xA data acquisition units to easily create state information, quickly build automated tests drive measurements to actionable insights faster.

Application Note 2017-07-03

PDF PDF 1.43 MB
How to Characterize a DC-DC Converter Using a DAQ and BenchVue Software - Application Note
This application note provides an easy, step-by-step approach for measuring and plotting several characteristics of a DC-DC converter using Keysight’s 34970A/72A DAQs with BenchVue software.

Application Note 2017-05-04

Optimize your wideband test solution
download new application note: Optimize your wideband test solution

Application Note 2017-02-21

The Advantage of Universal Inputs in Data Acquisition Systems - Application Brief
Learn how the 34970A/34972A DAQ system offers the versatility and powerful functionality you need to solve your most pressing test challenges.

Application Note 2017-02-03

Maximizing Battery Life of IoT Smart Devices with Keysight Solutions - Application Brief
This application brief details the design and test challenges involved with maximizing the battery life of Internet of Things (IoT) smart devices, and recommends Keysight solutions to address them.

Application Note 2016-07-14

Connecting Data Acquisition Systems to a Wireless Network - Application Brief
Learn how you can configure and take advantage of the latest router technology with either the 34972A DAQ system or any LXI instrument.

Application Note 2014-08-30

PDF PDF 659 KB
Quickly Identify Thermal Measurement Points For Data Acquisition - Application Brief
Temperature monitoring is a process that traditionally involves an amount of guess work. Learn how a thermal imaging camera can be used to quickly and easily identify temperature problem areas.

Application Note 2014-08-22

Characterizing the I-V Curve of Solar Cells and Modules
This measurement brief explores the various test and measurement tools you can use for I-V curve characterization and provides tips to help you choose the instrument or instruments that best fit your solar cell or module measurement needs.

Application Note 2014-07-31

1 2 3 4 Next