Here’s the page we think you wanted. See search results instead:

 

Contact an Expert

Data Acquisition – DAQ

DAQ System – More than 25 years of Leadership

Keysight has provided data acquisition (DAQ) and switching solutions for more than 25 years. We provide data acquisition solutions for electrical, physical, mechanical, acoustic and signal routing applications up to 50GHz.

Compare data acquisition (DAQ) switch platforms

Define a switching solution with switches, controllers and accessories.

  • Get the Best Value with high quality switching and measurements in compact, cost effective solutions
  • Use on Industry Standards with modular LXI and VXI solutions
  • Use the Keysight’s Application Software to collect, analyze and present your data real-time

Check out Keysight next-generation multi-channel data acquisition (DAQ) system — sample more signals, faster!

51-75 of 373

Sort:
34972A 3D Model, STEP Format
STEP format 3D Model of the 34972A LXI Data Acquisition / Data Logger Switch Unit with modules installed. Use this model as a reference only.

Technical Overview 2018-08-27

ZIP ZIP 12.91 MB
DAQM90xA Data Acquisition modules 3D Model, STEP Format
This is a STEP format 3D Model of the DAQM90xA Data Acquisition Modules

Technical Overview 2018-08-24

ZIP ZIP 6.34 MB
Make Better AC RMS Measurements with Your Digital Multimeter - Application Note
Learn about the complexity of ac rms measurements and how to deal with them

Application Note 2018-08-17

Accurately measure path loss for over the air transmitter and receiver measurements
This application note describes how to improve the accuracy of the Keysight X8711A by properly measuring path loss and applying the right system offset in the test plan.

Application Note 2018-08-16

PDF PDF 981 KB
4 Things to Consider When Using a DAQ as a Data Logger
Product designs keep increasing in complexity. So do product test requirements. Learn how to improve test development cycle time, choose the right setup to optimize your test time, and improve the accuracy of your data acquisition test system.

Application Note 2018-08-07

DC-DC Converter Testing - Case Study
Manufacturer of automotive DC-DC converters slashes test time by 95 percent.

Case Study 2018-07-17

PDF PDF 4.49 MB
How to Optimize Measurement Speed of Your DAQ - White Paper
This white paper will show you how to optimize the measurement speed of a midrange DAQ system, Keysight’s DAQ970A system, to meet most of your design validation tests. You will learn how to choose the right hardware and configuration settings that will help you optimize your measurement and transactional speed.

Application Note 2018-07-17

IoT Device Functional Test Solution
Keysight's functional test solution helped a hearing aid manufacturer simplify product testing process, saving test time and reducing costs and risks to result in improved throughput of their new hearing aid with BLE connectivity.

Case Study 2018-06-19

PDF PDF 1.93 MB
X8711A IoT Device Functional Test Solution - Configuration Guide
This document helps you configure the entire X8711A IoT Device Functional Test Solution, including both hardware and software.

Configuration Guide 2018-06-19

PDF PDF 1.70 MB
Keysight X8711A IoT Device Test Solution – USB 2.0 Hub (0960-3383) - Operating Instructions
Contains instructions to set up the USB 2.0 hub for X8711A solution.

Operation Manual 2018-06-01

PDF PDF 203 KB
Testing Next Generation AC Controller with BLE Radio Technology - Application Brief
How an air conditioner manufacturer tested their next generation controller with Bluetooth Low Energy radio technology.

Application Note 2018-04-11

PDF PDF 695 KB
Achieve Accurate Two Wire Resistance Measurements with the Keysight 34923A and 34924A Multiplexers -
This application note provides an overview of how to make an accurate two-wire resistance measurement with the Keysight 34980A and a multiplexer.

Application Note 2018-03-20

M9155/6/7C and M9155/6/7CH40 DC to 26.5/40 GHz PXI Hybrid Switch Modules - Flyer
This 2-page flyer provides a brief overview for the Keysight M9155/6/7C PXI and M9155/6/7CH40 DC to 26.5/40 GHz PXI Hybrid Switch Modules.

Brochure 2018-01-17

PDF PDF 556 KB
M9155/6/7C PXI Hybrid Switch Modules - Data Sheet
This data sheet provides a detailed product descriptions, specifications, configuration information, and ordering information for M9155/6/7C PXI Hybrid Switch Modules.

Data Sheet 2018-01-10

PDF PDF 2.83 MB
M9161D PXI Dual SP4T Solid State Switch Module - Data Sheet
The data sheet describes features, benefits, and specifications for the M9161D PXI dual SP4T sofid state switch module.

Data Sheet 2018-01-01

PDF PDF 1.51 MB
Achieve Accurate Resistance Measurements with the Keysight 34980A Multifunction Switch Measure Unit
This application note provides an overview of how to make an accurate 2-wire, 3-wire and 4-wire resistance measurements with the Keysight 34980A

Application Note 2017-12-05

Access Your 34972A Wirelessly with a Sapido Mobile Router - Technical Overview
This measurement tip provides the steps needed to turn a 34972A unit into a wireless data acquisition system with the help of a Sapido RB-1632 mobile router.

Technical Overview 2017-12-05

PDF PDF 2.97 MB
Bench and System Switching Products - Selection Guide
Whether you use switching to route signals for design verification applications or for complex automated functional test systems, reliable and repeatable switching is critical for your measurement accuracy.

Brochure 2017-12-01

PDF PDF 11.37 MB
PXI RF Switch Modules - Flyer
One-page overview of the Keysight PXI RF switch modules including a brief summary of features, specifications, configuration, and ordering information.

Brochure 2017-12-01

PDF PDF 688 KB
Ensuring Medical Alert Pendants are Accurate and Reliable with Modular Functional Test
This application note shows how the 34980A multi-function switch/measure unit is being used to test medical alert devices.

Solution Brief 2017-12-01

PDF PDF 1.06 MB
Temperature Measurement Solution for Solar Cell and Module Testing - Application Note
This application note highlights key products that can be used to help you effectively and efficiently test solar cells and solar modules, and ensure that they are able to perform optimally.

Application Note 2017-10-25

IO Libraries Minimum System Requirements - Technical Overview
Computer hardware and operating system minimum requirements for using Keysight IO Libraries Suite.

Technical Overview 2017-10-11

Test and Measurement Basics – DAQ
Spend 2 minutes on each topic ranging from the fundamentals of data acquisition to the more complex configurations of DAQ instruments. Simple and easy solutions to your DAQ related questions.

Demo 2017-09-10

34934A High Density Matrix Module - User’s Guide
Configuration and programming information for the 34934A high density matrix module.

User Manual 2017-08-01

PDF PDF 3.20 MB
Using BenchVue to Create and Execute Scan Lists on 3497xA Data Acquisition Units - Application Note
Lean how Keysight's BenchVue software can be used with 3497xA data acquisition units to easily create state information, quickly build automated tests drive measurements to actionable insights faster.

Application Note 2017-07-03

PDF PDF 1.43 MB

Previous 1 2 3 4 5 6 7 8 9 10 ... Next