Version: $Id$
Generated with T3Doc 2.0 on Fri Jan 30 15:06:38 CET 2009.
Configuration
Specific requirements:
- REG:
- Idle mode supported
- Power save class Type 1 supported
Description
Test Strategy: The preamble completes the Initial Ranging and the Negotiation of Basic Capabilities.
Also it completes the registration procedure. Then, BS Tester triggers IUT to define
a Power Saving Class I. BS Tester does not reply to MOB_SLP-REQ. Check that IUT does
not retransmit request before expiration of T43.
Purpose
TP/MS/SLM/PW1/TI-H001a
TP version: 0.0.14
Initial condition: The IUT has completed initial network entry with the BS and has sent a Bandwidth
request and uplink sleep control header for activation of a Power Saving Class of
type 1. The BS does not reply.
Test purpose: Check that: the IUT shall not retransmit Bandwidth request and uplink sleep control
header before expiry of the T43 timer.