*********************** **** Read Me First **** *********************** Version 1.2.1019.1 Sep 04, 2015 Introducing the AgM9393 IVI Driver for the Keysight M9393 PXI Modules --------------------------------------------------------------------------- This instrument driver provides access to the functionality of M9393 PXI Modules through a COM server or ANSI C API which also complies with the IVI specifications. This driver works in any development environment which supports COM or C programming including Microsoft Visual C++, Microsoft .NET, Keysight VEE Pro, National Instruments LabView, LabWindows CVI, MATLAB(32 bit only) and others. Supported Instruments --------------------- M9214A Digitizer M9300A Reference M9308A Synthesizer M9365A Wideband Downconverter Installation ------------- System Requirements: The driver installation will check for the following requirements. If not found, the installer will either abort, warn, or install the required component as appropriate. Supported Operating Systems: Windows 7 Shared Components Before this driver can be installed, your computer must already have the IVI Shared Components installed. Minimal IVI Version: 2.2.1 The IVI Shared Components installer is available from: http://www.ivifoundation.org/shared_components/Default.aspx VISA The latest version of Keysight's IO Libraries is recommended and includes VISA. You can download the latest version from: http://www.keysight.com/find/iosuite Uninstall --------- This driver can be uninstalled like any other software from the Control Panel using Windows 7. The IVI Shared Components may also be uninstalled like any other software from the Control Panel using Windows Windows 7. Note: All IVI-COM/C drivers require the IVI Shared Components to function. To completely remove IVI components from your computer, uninstall all drivers and then uninstall the IVI Shared Components. Source Code ----------- Driver source code is available by choosing "Custom" and selecting "Source Code" when installing the driver. This code is provided as is for informational purposes only. Modification of this code is not supported. Caution: Once you have installed version 2.x of the IVI Shared Components, you will not be able to build IVI drivers and applications developed with earlier versions. You will need to upgrade those drivers/applications to the new IVI Shared Components and to build on Visual Studio 2008 or higher or you will need to build those drivers/applications on a different machine that does not have version 2.x of the IVI Shared Components. Start Menu Help File -------------------- A shortcut to the driver help file is added to the Start Menu, All Programs, Keysight IVI Drivers, AgM9393 Receiver group. It contains "Getting Started" information on using the driver in a variety of programming environments as well as documentation on IVI and instrument specific methods and properties. You will also see shortcuts to the Readme file and many programming examples for this driver. Additional Setup ---------------- .NET Framework The .NET Framework itself is not required by this driver. If you plan to use the driver with .NET, the minimal .NET framework version is: 2.0 The .NET Framework requires an interop assembly for a COM server. A Primary Interop Assembly, along with an XML file for IntelliSense is installed with the driver. The driver's PIA along with IVI PIAs are installed by default in: :\Program Files <(x86)>\IVI Foundation\IVI\Bin\Primary Interop Assemblies The PIA is also installed into the Global Assembly Cache (GAC) if you have the .NET framework installed. Using a New Version of the Driver --------------------------------- New versions of this Keysight IVI-COM/C driver may have a new ProgId. If you use the version dependent ProgId in CoCreateInstance, you will need to modify and recompile your code to use the new ProgID once you upgrade to the next version of the driver. Doing a side-by-side installation of the driver to use multiple versions of the driver is not supported. If you need to go back to an older version of the driver, you need to uninstall the later version and install the older version. If you use the version independent ProgId in CoCreateInstance, you will not need to modify and recompile your code. The new version of the driver has been tested to be backwards compatible with previous versions. To access the new functionality in a new version of the driver you will need to use the latest numbered IAgM9393[n] interface rather than the IAgM9393 interface. The IAgM9393[n]. property will return a pointer to the new IAgM9393>[n] interface. The IAgM9393[n] interface contains the methods and properties for the new functionality. The new interfaces were introduced rather than modifying the existing interfaces for backwards compatibility. The interfaces that were previously shipped have not been changed. Pre-existing .NET client applications must be re-build before using the new version of the driver. Known Issues ------------ This driver does not have any known defects. Revision History ---------------- Version Date Notes ------- -------- ----- 1.0.70.0 Jul 09, 2014 Initial public release 1.0.80.1 Aug 07, 2014 Documentation updates. Various defects fixed: - Alignments fail if conversion mode is not set to Auto. - Alignments fail if multiple instances of M9393 in the same process. - Corrected trigger qualification of wideband burst trigger for IVI and 89600. - 89600: Reconnecting to M9393 from 89600 fails in certain sequences. - 89600: Large span to RBW ratios may generate errors. - 89600: Certain triggered measurements stall if trigger not received in 1 sec. - 89600: Incorrect power reading at certain settings when using average detector. - 89600: Corrected handling of trigger delay limits. - 89600: Minimum span can be less than 800 Hz. - 89600: Interaction with M90XA when running in process with 89600. - 89600: Overlap Percentage error with Gate Trigger and Power Spectrum. 1.1.240.0 Sept 18, 2014 Added LabVIEW driver for AgM9393. Added IF Dither mode for Stepped Spectrum. See IAgM9393Ex2.SteppedSpectrumAcquisition2.IFDither.* Added multi-channel synchronization. See IAgM9393.MultiChannelSync.* Documentation updates. Various defects fixed: - Comprehensive alignment failed if initial instrument state is Stepped Spectrum and conversion is image protect - 89600: Overlap Percentage error with Gate Trigger and Power Spectrum 1.1.518.1 Feb 10, 2015 89600: allow driver sharing using M9000 resource manager for multi-channel configurations Various defects fixed: - WIT 353338 – Issue starting system if locale uses comma as decimal separator - WIT 357918 – LO Nulling intermittently fails on some systems - WIT 369709 – Issue with field calibration resulting in ~0.2 dB flatness error on some units - WIT 335725 – 89600: error reported when IF Dither enabled and Span/RBW ratio too large - WIT 353408 – 89600: error reported when switching between IF Mag & External Trigger in Sequenced Mode - WIT 353905 – 89600: minimum gate length limited to 100 ns in zero span - WIT 355118 – 89600: added VBW limiting in zero span - WIT 356920 – 89600: channel filter was not set correctly for non-power spectrum measurements - WIT 359033 – 89600: allow higher Span to RBW ratio based on physical memory available 1.1.522.2 Mar 10, 2015 Field calibration enhancement to improve expected input level accuracy Various defects fixed: - WIT 361207 – Fixture Loss Enabled is now set to False on Reset (previously was unchanged) 1.2.1016.0 May 07, 2015 Support for M9415A Peer To Peer operation. Not supported via IVI. Support for M9415A Noise Correction in FFT Acquisition Mode. Not supported via IVI. Various defects fixed: - WIT 385288 - LO Feedthrough causes IF Overloads when using Noise Corrections - WIT 391319 - Interaction with M90XA prevents newer M90XA versions from running 1.2.1019.1 Sep 04, 2015 Various defects fixed: - Corrected frequency scaling for soft front panel FFT Acquisition mode - Increased maximum value for soft front panel IQ averaging period to match IVI maximum - Fixed intermittent glitch on narrowband time trace after using FFT Acquisition mode IVI Compliance -------------- IVI-COM/IVI-C Custom Specific Instrument Driver IVI Instrument Class: None Optional Features: Interchangeability Checking no State Caching no Coercion Recording no Driver Identification: Vendor: Agilent Technologies Description: M9393 PXI Module Family Driver Revision: 1.2 Component Identifier: AgM9393.AgM9393 Hardware Information: Instrument Manufacturer: Agilent Technologies Supported Instrument Models: M9214A, M9300A, M9308A, M9365A Supported Bus Interfaces: PXIe 32-bit Software Information: Supported Operating Systems: Windows 7 32 Unsupported Operating Systems: Windows 2000, XP, Vista Support Software Required: VISA Source Code Availability: Source code included with driver. 64-bit Software Information: Supported Operating Systems: Windows 7 64 Unsupported Operating Systems: Windows Vista 64 Support Software Required: VISA Source Code Availability: Source code included with driver. More Information ---------------- For more information about this driver and other instrument drivers and software available from Keysight Technologies visit: http://www.keysight.com/find/adnivicominfo A list of contact information is available from: http://www.keysight.com/find/assist Microsoft, Windows, MS Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. © Keysight Technologies 2015, All rights reserved.