Copyright (C) 2004, 2005-2013 Agilent Technologies, Inc. ATTENTION: PLEASE READ THE AGILENT LICENSE TERMS BEFORE INSTALLING OR OTHERWISE USING THE LICENSED MATERIALS. ALL USE OF THESE LICENSED MATERIALS IS SUBJECT TO THE ACCOMPANYING LICENSE TERMS. "LICENSED MATERIALS" INCLUDES THE SOFTWARE, ANY WHOLE OR PARTIAL COPIES, AND ANY ACCOMPANYING INSTRUCTIONS, DOCUMENTATION, TECHNICAL DATA, IMAGES, RECORDINGS AND OTHER RELATED MATERIALS. Table of Contents: ================== 1. Agilent AcqirisMAQS Software File List 2. Release History 1. Agilent AcqirisMAQS Software File List: ========================================== InstallationDirectory = %ProgramFiles%\Agilent\Acqiris Destination Directory = \Uninstall (misc. install files) MAQS6.1irunin.* IRIMGx.BMP lua51.dll uninstall.exe IRZip.lmd Wow64.lmd agilent.ico Destination Directory = \AcqirisMAQS (Instrument Temperature Watchdog application) AcqirisITW(_64).exe (Client-side application) AcqirisMAQS(_64).exe (License document) AgilentLicenseTerms.pdf (Measurement functionality) AqMeasStd(_64).dll (License certificate) LicenseCertificate.txt (Client Interface libraries) AqDD_4(_64).dll AqIC_4(_64).dll AqSC_4(_64).dll (Server-side application) AqServer5(_64).exe (Export tool) ExportToASCII(_64).exe (Factory settings file) FactoryInstrumentSettings.AqSettings (Qt 4.7.3 components) Qt3Support4(_64).dll QtCore4(_64).dll QtGui4(_64).dll QtNetwork4(_64).dll QtSql4(_64).dll QtHelp4(_64).dll QtXml4(_64).dll QtCLucene4(_64).dll QtWebKit4(_64).dll (Qt external component 4.4.0) phonon4(_64).dll (C++ example) AqHDF5Reader.cpp Destination Directory = \bin\lang (French translation files) *_fr.qm Destination Directory = \html Contains the html documentation files for AcqirisITW & AcqirisMAQS Destination Directory = \manuals (THIS information file) ReadMeAcqirisMAQS.txt (User Manuals) InstallAcqirisMAQS.pdf HDF5_RM_r185.pdf Destination Directory = \utl (Qt 4.7.3 component) assistant(_64).exe qt.conf Destination Directory = \plugins\sqldrivers (Qt 4.7.3 component) qsqlite4(_64).dll ================================================================================ 2. Release History: ==================== Agilent AcqirisMAQS 6.1.2 April 2013 ==================================== New features: ------------- * The 'Add measurement' command is now accessible with right-click anywhere within the entire horizontal header of the Trace table. * Name of the edited cursor is now displayed in the title of the 'Cursor Properties' dialog. * Added a new command 'Set Time Window Limits...' in the Waveform Display context menu. Fixes: ------ * Fixed restore settings of Spectrum Windows composed of several traces. * Fixed waveforms refresh when the data readout on channel 1 is disabled. * Fixed wrong coercion message in the Instrument Settings table. * Ensures that acquired data are available to the client. * Continue to acquire when a signal overload is detected during an Auto setup, Live and Normal run control modes. * Fixed Level Crossing computation of backward scan in Measurement functions. * Fixed the save configuration to file when executed from another client than AcqirisMAQS. * Save and recall last configuration works again. * Row labels in the Instrument Settings table are now updated when the name of an instrument has been edited. * Fixed server conflict when a U1051A (TC890) module is plugged in the system. * Fixed trace synchronization issue when acquisition is done with a very large number of samples (> 10 MSamples). * Memory leaks fixes. Known issues: ------------- * Connection with a server cannot be established if the IP address of the server has been changed dynamically (e.g. network cable disconnected) while the server was running. The server must be restarted. Versions: --------- AcqirisITW.exe 6.1.2.1888 AcqirisMAQS.exe 6.1.2.1891 AqDD.dll 6.1.2.1888 AqIC.dll 6.1.2.1388 AqMeasStd.dll 1.6.1.1251 AqSC.dll 6.1.2.1388 AqServer.exe 6.1.2.1388 ExportToASCII.exe 2.4.3.117 AcqirisITW_64.exe 6.1.2.1388 AcqirisMAQS_64.exe 6.1.2.1890 AqDD_64.dll 6.1.2.1388 AqIC_64.dll 6.1.2.1388 AqMeasStd_64.dll 1.6.1.1250 AqSC_64.dll 6.1.2.1388 AqServer_64.exe 6.1.2.1388 ExportToASCII_64.exe 2.4.3.117 ________________________________________________________________________________ Agilent AcqirisMAQS 6.0.1 June 2012 =================================== * 64 bit support. * M9703A support. * Added a custom files prefix editor in 'Save All Traces' dialog. * Added 'Ctrl+S' shortcut to open the 'Save All Traces' dialog. * Regrouped Save/Load Layouts for Application, Waveform Display, and Counter Display in the File menu. * New attributes: 'Segment Counter Mode', 'Max Samples Per Segment', 'Dithering', 'Data Bandwidth', 'TRG Bandwidth', 'Frequency Shift', 'Flip Band', 'Double Data Rate' and 'Ctrl I/O C'. * Simulated ASBus multi-instruments no longer available via the 'Create simulated digitizer, averager and analyzer' dialog (only supported via the IS_simulation.AqConfig file). * The generated instrument simulation file is saved in %USERPROFILE%\AqServer5 folder. * Fixed CPU resource usage on waveform request when no acquisition done yet. * Fixed memory leaks & unreferenced pointer when getting attribute value. * Ensure that all traces are visible after a load from a file. * Ensure to display traces of the latest acquisition. * Enhanced waveform communication between client and server. * Fixed refresh of traces when dataReaout attribute is set to off. * Removed the useless 'TCP port' line edit in the Network tab of the Preferences dialog. * Added read data state indicator for channel items in the Channel View. * Recovery folder names begins with 'Recovered_'. * Fixed status display in SingleShot dialog. * Fixed a recursive display of an error message box when editing a Backup folder name that doesn't have a recovery file. * Fixed refresh of Instrument Settings after Autosetup. * Fixed row ordering of channels after hide/show. * Detect replaced multi-instrument slave when loading a system configuration. Known issues: ------------- * Connection with a server cannot be established if the IP address of the server has been changed dynamically (e.g. network cable disconnected) while the server was running. The server must be restarted. Versions: --------- AcqirisITW.exe 6.0.1.146 AcqirisMAQS.exe 6.0.1.146 AqDD.dll 6.0.1.146 AqIC.dll 6.0.1.146 AqMeasStd.dll 1.5.1.12 AqSC.dll 6.0.1.146 AqServer.exe 6.0.1.146 ExportToASCII.exe 2.4.1.94 AcqirisITW_64.exe 6.0.1.145 AcqirisMAQS_64.exe 6.0.1.145 AqDD_64.dll 6.0.1.145 AqIC_64.dll 6.0.1.145 AqMeasStd_64.dll 1.5.1.11 AqSC_64.dll 6.0.1.145 AqServer_64.exe 6.0.1.145 ExportToASCII_64.exe 2.4.1.93 ________________________________________________________________________________ Agilent AcqirisMAQS 3.5.2 June 2011 =================================== Fixed only the installer: * Check for an installed MD1 (or AS) only when 'Install Agilent AcqirisMAQS' or 'Install the Server only' is selected in the Options screen. * Allow user to select another option if MD1 (or AS) is not detected when 'Install Agilent AcqirisMAQS' or 'Install the Server only' option is selected. * Allow user to select another option if the client is not installed when 'Enter a License Key' option is selected. Known issues: ------------- * Connection with a server cannot be established if the IP address of the server has been changed dynamically (e.g. network cable disconnected) while the server was running. The server must be restarted. Versions: --------- AcqirisMAQS.exe 3.5.1.77 AqDD_4.dll 4.1.3.438 AqSC_4.dll 4.3.3.706 AqIC_4.dll 4.3.1.71 AqMeasStd.dll 1.4.5.249 AcqirisITW 2.2.2.9 ExportToASCII 2.1.2.1 AqServer5.exe 5.6.1.36 AqLibraries 4.1.2 ________________________________________________________________________________ Agilent AcqirisMAQS 3.5 May 2011 ================================ * The Tools/ExportToASCII dialog contains a terminal widget that display the execution progress. * New column 'Information' in the Server Search dialog which display additionnal info about a server item and the connection retry information when the client lost the connection with the server. * New dialog in the Server Search to allow search of a server with his IPv4 address. * Agilent scopes: Activated lock of the front panel buttons (Note: mouse and keyboard still active). AUX now available as trigger source. * Added a new service: RunSingle; start a Single run mode and wait for acquisition completion (with timeout). * Added new attribute 'NBRADCBITS'. * Added DDC attributes: 'axDitherEnable', 'axDoubleDataRate', 'axFlipBand', 'axDataBandwidth', 'axTriggerBandwidth', 'axFreqShift'. * Use AgMD1Fundamental.dll instead AqDrv4.dll. * Don't use AcqirisDxDir and AcqirisDxRoot environment variables anymore. * A connection to a server without instrument is not allowed. * No more possible to create simulated ASBus instrument. Known issues: ------------- * Connection with a server cannot be established if the IP address of the server has been changed dynamically (e.g. network cable disconnected) while the server was running. The server must be restarted. Versions: --------- AcqirisMAQS.exe 3.5.1.70 AqDD_4.dll 4.1.3.431 AqSC_4.dll 4.3.3.661 AqIC_4.dll 4.3.1.36 AqMeasStd.dll 1.4.5.241 AcqirisITW 2.2.2.9 ExportToASCII 2.1.2.1 AqServer5.exe 5.6.1.25 AqLibraries 4.1.2 ________________________________________________________________________________ AcqirisMAQS 3.4 June 2010 ========================= * Added -car and -cgr cmd line options to AcqirisMAQS and AqServer5 to clear all or GUI-only user registry info on startup * Added possibility to connect to servers outside of IP subnet by providing their IPv4 address. Servers may be added with the 'Manage Servers...' button in the 'Server Search' dialog. * Physical instruments (of any class) are ignored if option 'Start in simulation mode' of the server is selected * Plug-ins must be placed in 'AcqirisMAQS' subfolder (previously 'bin' subfolder) of the application folder * Corrected error preventing multiple cells modification in the Instrument Settings table if the edited cell's value does not change * A 'channelName' column is now included in all tabs of the Instrument Settings to allow sorting (hidden by default except in 'Input' tab). * Channels, Setup Manager and Instrument Settings windows are correctly updated when a channel or instrument name is modified Known issues: ------------- * Connection with a server cannot be established if the IP address of the server has been changed dynamically (e.g. network cable disconnected) while the server was running. The server must be restarted. Versions: --------- AqDrv4.dll 4.17.5.86 AcqirisMAQS.exe 3.4.1.154 AqDD_4.dll 4.1.2.159 AqSC_4.dll 4.3.2.568 AqIC_4.dll 4.2.1.106 AqMeasStd.dll 1.4.3.1365 AcqirisITW 2.2.1.68 ExportToASCII 2.1.1.68 AqServer5.exe 5.5.2.27 AqLibraries 4.1.2 ________________________________________________________________________________ AcqirisMAQS 3.3 March 2010 ========================== * Added -h command line option (usage help) * Fixed Autostore problem following switch from Live mode * Fixed Time Counter data files generation and conversion to ASCII * Fixed problem with Time Counter data files generation in Recovery mode (S/S2 license) * Fixed cmd line option -l (load layout file) * Fixed several problems with the Search Server dialog * Calibration state in the server display correctly updated * Fixed potential crash due to corrupted Factory Settings file * Replaced command file by -d60 cmd line option to delay AqServer5 startup * Fixed disappearance of remote servers when Search Server dialog remains open * Fixed crash due to presence of unsupported TC890 instrument Known issues: ------------- * Connection with a server cannot be established if the IP address of the server has been changed dynamically (e.g. network cable disconnected) while the server was running. The server must be restarted. Versions: --------- AqDrv4.dll 4.17.4.255 AcqirisMAQS.exe 3.3.2.2 AqDD_4.dll 4.1.2.1 AqSC_4.dll 4.3.2.185 AqIC_4.dll 4.1.2.91 AqMeasStd.dll 1.4.3.1364 AcqirisITW 2.2.1.3 ExportToASCII 2.1.1.63 AqServer5.exe 5.4.2.3 AqLibraries 4.1.2 ________________________________________________________________________________ AcqirisMAQS 3.2 November 2009 ============================= * AcqirisITW: Add armed and locked states, optical_receive, board_inhibited, board_armed and trigger_status states for GDRs in temperature control broadcast via UDP * Fixed instrument arming error 'Unable to access to registry' for non administrator user * Apply button in Preferences dialog acts for all panels of the dialog * Fixed Counter Display not taking into account TimeOffset, Time2ndOffset and Time3rdOffset * Fixed creation of Time Counters data files with >1 channel * Added TimeOffset, Time2ndOffset and Time3rdOffset in Time Counters data files under Header/Instrument/Channel.chn * Fixed temperature reading for GDR instruments (S2 license) Versions: --------- AqDrv4.dll 4.16.2.29 AcqirisMAQS.exe 3.2.1.29 AqDD_4.dll 4.0.3.85 AqSC_4.dll 4.2.1.45 AqIC_4.dll 4.0.4.41 AqMeasStd.dll 1.4.3.1102 AcqirisITW 2.2.1.3 AqServer5.exe 5.3.1.12 AqLibraries 4.0.4 ________________________________________________________________________________ AcqirisMAQS 3.1 September 2009 ============================== IMPORTANT WARNING: Due to the migration to Qt4, AcqirisMAQS 3.x clients and servers are not compatible with previous 2.x versions. * Added status of GFT1208 instruments in the Channel View (S2 license) * New option in AcqirisITW to broadcast status via UDP * Fixed saving of FFT waveform from RAM to file * Fixed Waveform Display refresh slowdown due to channel data readout set to off * Fixed error reporting of unsuccessful load of configuration due to instrument busy * Fixed "TVField" attribute not modifiable for supporting models * Fixed problems of storing acquisition data to file for large numbers of samples and/or segments Versions: AqDrv4.dll 4.16.2.29 AcqirisMAQS.exe 3.1.2.29 AqDD_4.dll 4.0.3.15 AqSC_4.dll 4.1.1.54 AqIC_4.dll 4.0.3.19 AqMeasStd.dll 1.4.3.1093 AcqirisITW 2.1.1.7 AqServer5.exe 5.2.1.17 AqLibraries 4.0.3 ________________________________________________________________________________ AcqirisMAQS 3.0 March 2009 ========================== * Migrated to Qt4 GUI toolkit * Instrument Settings and Setup Manager are dockable windows * Custom Counter Display now managed in the Preferences dialog * Support TC842 in Common Start mode * Renamed GFT1208 'Elec' channel to 'Elec-Op1' (S2 license) * Fixed read-only channels not shown in italic * Fixed instrument list corruption in AqServer due to identical chassis number and instrument serial number Versions: AqDrv4.dll 4.15.6.37 AcqirisMAQS.exe 3.0.1.368 AqDD_4.dll 4.0.1.5 AqSC_4.dll 4.0.1.14 AqIC_4.dll 4.0.1.6 AqMeasStd.dll 1.4.3.653 AcqirisITW 2.0.1.7 AqServer5.exe 5.0.1.7 AqLibraries 4.0.1 ________________________________________________________________________________ AcqirisMAQS 2.2 September 2008 ============================== * Support the full range of the TC840 (21.47s) * Support for the GFT1208 driver 1.3.4.0 (S2 license) * Unexpected triggers detected in Single Shot (S/S2 license) * Fixed refresh of Time Counter channel values in the Counter Display * Fixed automatic advance to 'Arm your system' in Shot mode (Single Shot, S/S2 license) * Network Connection preferences moved to new 'Network' tab * New shortcuts in Trace table: Ctrl+A to show/hide all traces, Ctrl+I to invert show/hide state * Time Counter channels times can be added to Waveform display Versions: AqDrv4.dll 4.13.3.7 AcqirisMAQS.exe 2.2.1.88 AqDD_3.dll 3.7.1.135 AqSC_3.dll 3.15.1.158 AqIC_3.dll 3.11.1.19 AqMeasStd.dll 1.4.3.0 AcqirisITW 1.1.2.83 AqServer4.exe 4.4.1.50 AqLibraries 3.19.1 ________________________________________________________________________________ AcqirisMAQS 2.1 February 2008 ============================= * New license AcqirisMAQS-S2 for GFT1208 Digital Delay Generator support * New tab in Instrument Settings for Time-to-Digital Converter attributes * New tab in Preferences dialog for Time-to-Digital Converter options * New directories option for Layout in the General tab of Preferences dialog * Counter Display supports attribute references * Fixed Counter Display cell delete * Fixed Counter Display cell formatting being lost after cell value deletion * Display of serial number in Instrument Settings fixed * Fixed problems of reset of persistence in Waveform Display * Fixed XY display * Fixed inversion of Y axis when loading data with negative scaling factor * Fixed broken communication ports option * Fixed activeChannels info in HDF data files which could be truncated * Fixed AqServer log files problems * Instrument is stopped when switching its current state machine * Fixed the 'use last loaded configuration' in the Single Shot dialog when the automatic procedure option is disabled (S/S2 license) * Use native Open/Save file dialog to display shared network drive names * Added option for file preview in the Read Setup/Configuration dialog * Added option to allow multiple identical references in a Counter Display Versions: AqDrv4.dll 4.13.3.7 AcqirisMAQS.exe 2.1.6.1 AqDD_3.dll 3.6.1.279 AqSC_3.dll 3.14.4.3 AqIC_3.dll 3.9.11.164 AqMeasStd.dll 1.4.2.234 AcqirisITW 1.1.1.74 AqServer4.exe 4.3.5.1 AqLibraries 3.18.1 ________________________________________________________________________________ AcqirisMAQS 2.0 July 2007 ========================= * New Instrument Temperature Watchdog monitoring tool * Trace Identifier Format fully implemented for Waveform Display #2649 * Enabled the Help button in the Waveform Display Properties and added F1 shortcut in Waveform Displays * New option to set Waveform Display title with path of loaded trace * Fixed crash when reading hdf5 file containing more than 9 channels * Delayed calibration on start is canceled by first Calibrate/Fastcal command * Fixed detection of hardware failure during Single Shot procedure #2779 * New Custom Counter Display tool button #2745 * Single Shot: Abort button enabled and Cancel button disabled when first instrument triggers * Fixed Live mode acquisition not starting after switch from Single Shot mode #2882 * Added acquisition number in the Trace Identifier format #2879 * Trace Identifier Format fully implemented #2649 * Use the new location for html documentation (%AcqirisDxRoot%/html/AcqirisMAQS) * Disable drop/paste of traces in the Waveform Display if the identifier is not valid #2833 * Signal quality indicator moved to the Waveform Display trace list #2271 * Check for forbidden characters in filenames (*, ?, ", <, > and |) * Added links to PDF manuals in AcqirisMAQS online help * Added support for DP1400 and DC140HZ * Fixed DC440 family, 10MHz Ext Ref, ExtCk Threshold not applied during calibrations #2836 Versions: AqDrv4.dll 4.12.3.4 AcqirisMAQS.exe 2.0.8.1 AqDD_3.dll 3.5.8.2 AqSC_3.dll 3.12.7.1 AqIC_3.dll 3.9.6.1 AqMeasStd.dll 1.4.2.3 AqServer4.exe 4.1.6.1 AqLibraries 3.15.5 ________________________________________________________________________________ AcqirisMAQS 2.0 February 2007 == Version 2.0 beta3 ============================= * Update data in Counter Display window also in Single Shot mode * New Reset button in Counter Display windows to reset data values * Data values automatically reset when starting a Single Shot procedure * Reading of HDF5 file from Counter Display window * Hardware timeout support in the server and in the client Versions: AqDrv4.dll 4.12.0.1601 AcqirisMAQS.exe 2.0.2.9 AqDD_3.dll 3.5.3.4 AqSC_3.dll 3.12.2.3 AqIC_3.dll 3.9.2.0 AqMeasStd.dll 1.4.1.1 AqServer4.exe 4.1.1.8 AqLibraries 3.15.1 ________________________________________________________________________________ AcqirisMAQS 2.0 December 2006 == Version 2.0 beta2 ============================= * Added Single Shot for TC840 Versions: AqDrv4.dll 4.12.0.895 AcqirisMAQS.exe 2.0.1.2 AqDD_3.dll 3.5.2.0 AqSC_3.dll 3.12.1.189 AqIC_3.dll 3.9.1.0 AqMeasStd.dll 1.4.0.29 AqServer4.exe 4.1.0.8 AqLibraries 3.15.0 _________________________________________________________________________________ AcqirisMAQS 2.0 June 2006 == Version 2.0 beta1 ========================= * First implementation of the Counter Display * Added support of TC840 & TC842 models Versions: AqDrv4.dll 4.11.1.85 AcqirisMAQS.exe 2.0.0.4 AqDD_3.dll 3.5.1.691 AqSC_3.dll 3.12.0.14 AqIC_3.dll 3.9.0.2 AqMeasStd.dll 1.4.0.29 AqServer4.exe 4.0.0.3 AqLibraries 3.14.0 ________________________________________________________________________________ AcqirisMAQS 1.6 May 2006 == Version 1.6 ======================== * Export tools plug-ins are automatically loaded at application startup * FFT: scale is now dBV (1Veff = 0dBV) * Faster automatic Single Shot procedure (no archive copy confirmation prompt) Versions: AqDrv4.dll 4.9.7.19 AcqirisMAQS.exe 1.6.1.267 AqDD_3.dll 3.5.1.288 AqSC_3.dll 3.11.0.220 AqIC_3.dll 3.8.1.125 AqMeasStd.dll 1.4.0.23 AqServer3.exe 3.8.4.238 AqLibraries 3.13.0 ________________________________________________________________________________ AcqirisMAQS 1.6 March 2006 == Version 1.6 beta ========================== * Invalidate FastCal as soon as the instrument configuration changes #2397 * HDF filenames (Single Shot and Autostore) are now configurable using Server options #2061 * Corrected acquisition timestamps for Autostore #2437 * Corrected the trace identifier construction when file contains multiple acquisitions #2430 * New Waveform Display popup menu item "Add Trace / Select.." that opens a selection tree with all instruments and traces for multiple selection * New Waveform Display popup menu item "Save as Image" with the options "Traces only", "Traces and Scales" or "Whole Window" * Fixed bug in Adjust mode where scaling to physical units was ignored * New Single Shot automatic procedure * New HDF2ASCII conversion in new Tools menu Versions: AqDrv4.dll 4.9.7.19 AcqirisMAQS.exe 1.6.0.0 AqDD_3.dll 3.5.0.0 AqSC_3.dll 3.10.0.0 AqIC_3.dll 3.8.1.0 AqMeasStd.dll 1.3.0.16 AqServer3.exe 3.8.3.0 AqLibraries 3.13.0 ________________________________________________________________________________ AcqirisMAQS 1.5.1 March 2006 == Version 1.5c ============================ * Use updated Acqiris Device Driver (release 2.15c, see ReadMe.txt) Versions: AqDrv4.dll 4.9.7.19 AcqirisMAQS.exe 1.5.1.9 AqDD_3.dll 3.4.0.2239 AqSC_3.dll 3.9.0.26 AqIC_3.dll 3.8.0.3 AqMeasStd.dll 1.3.0.16 AqServer3.exe 3.8.2.37 AqLibraries 3.12.2 ________________________________________________________________________________ AcqirisMAQS 1.5.1 January 2006 == Version 1.5b ============================== * Fixed bug causing items to be displayed in the wrong Channels tree branch in some cases #2393 * TCP and UDP communication ports are now user configurable. * Connections are no longer possible if client and server versions are incompatible #2388 * In Single Shot procedure, corrected a problem with HDF5 file comparison when using combined channels #2431 Versions: AqDrv4.dll 4.9.6.1 AcqirisMAQS.exe 1.5.1.9 AqDD_3.dll 3.4.0.2239 AqSC_3.dll 3.9.0.26 AqIC_3.dll 3.8.0.3 AqMeasStd.dll 1.3.0.16 AqServer3.exe 3.8.2.37 AqLibraries 3.12.2 ________________________________________________________________________________ AcqirisMAQS 1.5.0 January 2006 == Version 1.5a ============================== * Solved the problem of possibly inconsistent data display: channel waveforms from the same instrument are always from the same acquisition #1689 * Added AqServer, Device driver and IO driver versions information * Added firmware version and options in instrument information #2206 * Port to big endian machines (added Mac OSX PowerPC support) #2123 * Fixed an infinite loop when ruler height was too small #2284 * Use trace table with current keyboard focus for determining the instrument in adjust mode #2282 * Traces from disconnected servers will automatically reappear when the server is reconnected * When MEM:: traces are saved, they are converted into FILE:: traces with the file just saved * Before leaving the program or closing a waveform display window the user is prompted to save any MEM:: traces (otherwise they will be lost) * Added "Save all traces" command to save every visible waveform in the display * The time section can now be dragged on the whole top bar, not just the corners * When unlocking the x (time) rulers, the cursors split into multiple 'shadows' each of the color of the corresponding trace/ruler * For Single Shot operations, data are read twice and stored in different files which are then compared. Available disk space is checked before any new shot * Solved the problem of error code overwritten in instrument detection #2207 * Hidden options (not accessible throught preferences dialog) are not erased if user changes preferences * The server closes without confirmation dialog if the system is shutting down * Performance problem fixed in Autostore for large number of acquisitions to store #1960 * Fixed bug in Autostore causing potential bad first samples * Corrected rounding of some attribute values causing coercion problems #2182 * Increased static ranges for Scale Factor and Offset attributes #2030 * Removed re-calibration if calibration fails at server startup * Corrected a crash when number of segments is greater than 200 #1739 * In the server user interface, all commands to instruments are now disabled as soon as there is a 'master' client connected, or if the instrument is protected (e.g. in Single Shot operation with macro-commands) * Do not allow to close or restart the server if an instrument is busy or in a protected state (e.g. in Single Shot operation) * Fixed server freeze in interrupt mode #1987 * Added interactive creation of simulated instruments in server * Many improvements to Instrument Settings window: reset to Factory defaults, fixed spurious coercion errors in multi range cases, channel row painted with disabled color if the channel is disabled or if the data readout is off * Removed matching criteria for configuration reload, replaced with Configuration Status dialog #2075 * Undo/Redo improvements #2273 * Once a setup is renamed or modified (comments), its state is set to Renamed regardless of its current state #2279 * Removed channel state/quality indicator in Channel View, now implemented in the Waveform display window * Instruments and channels/externals are shown in italics if the instrument is in Read Only * A padlock is displayed when the instrument is locked * Many improvements to Single Shot operation: Shot/Trial modes, copy to archive step, remember dialog geometry * Added indicator for disk write speed in Autostore #1959 * Undo/Redo & Log dock windows are now regrouped in the Status tab dock window. * Use current directories in Save/Load dialogs for Layouts, Configurations, Setup Manager, Snapshot, Waveforms. * Added browse button when editing file paths in Instrument Settings Versions: AqDrv4.dll 4.9.3.17 AcqirisMAQS.exe 1.5.0.2264 AqDD_3.dll 3.4.0.1946 AqSC_3.dll 3.8.0.2270 AqIC_3.dll 3.7.1.59 AqMeasStd.dll 1.3.0.8 AqServer3.exe 3.8.1.110 AqLibraries 3.12.1 ________________________________________________________________________________ AcqirisMAQS 1.4.0 13 July 2005 == Version 1.4c ============================== * Fixed load of channel combine-changing configuration (double load was necessary) #2032 * For Single Shot operation, instrument calibration is considered valid for 24 hours * Fixed server crashes due to HDF5 library being not thread safe (added mutex) Versions: AqDrv4.dll 4.7.3.1 AcqirisMAQS.exe 1.4.0.83 AqDD_3.dll 3.3.3.63 AqSC_3.dll 3.7.3.19 AqIC_3.dll 3.6.0.90 AqMeasStd.dll 1.1.0.0 AqServer3.exe 3.7.4.0 AqLibraries 3.11.4 ________________________________________________________________________________ AcqirisMAQS 1.4.0 16 June 2005 == Version 1.4b ============================== * Fixed Adjust mode button disabling bug * Time sections in Waveform Display (when bottom area is shown) draggable only near the corners, not over the whole bars * Fixed bug causing occasional crashes when computing FFTs * Fixed bug causing occasional crashes when deleting traces in the Waveform Display * New context menu item for fullscale on x ruler * Update HELP files Versions: AqDrv4.dll 4.7.3.1 AcqirisMAQS.exe 1.4.0.83 AqDD_3.dll 3.3.3.63 AqSC_3.dll 3.7.3.19 AqIC_3.dll 3.6.0.90 AqMeasStd.dll 1.1.0.0 AqServer3.exe 3.7.2.3 AqLibraries 3.11.4 ________________________________________________________________________________ AcqirisMAQS 1.3.4 17 May 2005 == Version 1.3c ============================= * Fixed Adjust mode confusion with multiple servers #1876 * Enable/disable of Adjust mode button in Waveform display when channel is read-only access * All D1 instruments now supported in digitizer mode * Fixed startup options problem #1798 * Run Control commands (run, stop, etc.) are completely executed when read-only instruments are selected #1898 * Force to read the FactoryInstrumentSettings.AqSettings file from the AcqirisDxDir folder * Keep undo/redo lists when Instrument Settings window is closed #1909 * Fixed synchronization problem with configurables items that should be hidden when the application is started * Server name not automatically added if more than one server managed by the system #727 * Added H5Open() call to initialize the HDF module in all threads (was causing application crashes in some specific situations) Versions: AqDrv4.dll 4.7.0.2369 AcqirisMAQS.exe 1.3.4.10 AqDD_3.dll 3.3.2.101 AqSC_3.dll 3.7.2.10 AqIC_3.dll 3.6.0.37 AqMeasStd.dll 1.1.0.0 AqServer3.exe 3.7.1.30 AqLibraries 3.11.3 ________________________________________________________________________________ AcqirisMAQS 1.3.1 4 Apr 2005 == Version 1.3b ============================ * Fixed memory leaks * Cancel button has now a standard behavior - in previous versions, initial values were restored even if Apply had been pressed * Fixed Single Shot arm failure due to trigger threshold rounding problem when saving/checking configuration #1853 * Added AqServer About dialog box * Fixed bug where preferences were incorrectly loaded #1853.3 * Fixed instrument settings cells coercion display and enhanced coercion log messages * Fixed update of instruments and configurable names when a configuration is loaded * Same instrument or configurable name authorized in the Channels tree #727 Versions: AqDrv4.dll 4.6.0.3195 AcqirisMAQS.exe 1.3.1.49 AqDD_3.dll 3.3.1.6 AqSC_3.dll 3.6.0.49 AqIC_3.dll 3.5.0.523 AqMeasStd.dll 1.1.0.0 AqServer3.exe 3.6.1.34 AqLibraries 3.11.0 ________________________________________________________________________________ AcqirisMAQS 1.3 14 Mar 2005 == Version 1.3a =========================== * Fixed client crash when deleting traces #1749 * Improved performance * StdDev waveform measurement function added * Multi-language support (English and French are available) * Implementation of Channel Summary pop-up * Fixed bug when Y axis is expressed in dB: full-scale signal = 0 dB * The SI unit scaler was chosen inappropriately for the cursor readouts in the display and in the trace table cursor panel * For local version, activate instrument configuration and unlimited configurable options. * Removed Connect to... command * Restore last server connections * Improved Preferences * Fixed client crash when the channel list contains more than 20 instruments * Added a data tab in Preferences to set default path for data files management * Enhanced Network communication performance * Fixed M-License rights for server connection #1826 * Major modifications in the Single Shot implementation and user interface * Fixed temperature reading at Server start-up * Added FastCal calibration mode * Added simulation of multi-instruments * Fixed AutoSetup failure for instruments with short memory length * Changed output folder creation for AutoStore (uses a temporary folder) #1807 * Fixed server slowdown due to XY traces where X and Y are from the same source #1841 * Fixed saving configuration collapsing all instruments in the Channel View #1748 * Fixed access violation when loading an invalid Configuration * Added table snapshot: uses only shown attributes if Instrument Settings Window is open and 'Snapshot only displayed attributes' is checked in Preferences * Extended drag&drop selection to instrument parents (e.g. server) * Display the ratio peak-peak/FS in a channel tooltip and info part * Improved AutoStore user interface * Added Single Shot monitoring mode Versions: AqDrv4.dll 4.6.0.3195 AcqirisMAQS.exe 1.3.0.1765 AqDD_3.dll 3.3.0.1101 AqSC_3.dll 3.5.0.1430 AqIC_3.dll 3.5.0.390 AqMeasStd.dll 1.1.0.0 AqServer3.exe 3.6.0.659 AqLibraries 3.10.0 ________________________________________________________________________________ AcqirisMAQS 1.2 (December 6, 2004) == Version 1.2a ================================== Versions: AqDrv4.dll 4.5.0.4771 AcqirisMAQS.exe 1.2.1.76 AqDD_3.dll 3.2.2.14 AqSC_3.dll 3.4.2.12 AqIC_3.dll 3.4.2.12 AqMeasStd.dll 1.0.0.56 AqServer3.exe 3.5.3.15 AqLibraries 3.8.4 _end_of_file____________________________________________________________________