N2753A and N2754A Windows XP to Windows 7 Upgrade Kits - Configuration Guide
Keysight's N2753A and N2754A Windows XP to Windows 7 upgrade kits help you transition your Infiniium 9000, 90000, and 90000 X-Series oscilloscopes' operating systems.

Data Sheet 2014-08-01

N5392A Ethernet Electrical Performance Validation and Compliance Software - Data Sheet
The Keysight Technologies N5392A Ethernet electrical performance validation and compliance software for Infiniium 54830 and 54850 Series oscilloscopes provides you with a fast and easy way to verify and debug your 1000Base-T, 100Base-TX and 10Base-T Ethernet designs. The Ethernet electrical test software

Data Sheet 2014-08-01

N1010A FlexDCA Virtual Device Demonstration
This 3-minute video shows how the Keysight N1010A FlexDCA software can help semiconductor companies sell high-speed semiconductors

Demo 2014-08-01

N1010A De-Embedding Software - Data Sheet
N1010A FlexDCA Remote Access Software provides oscilloscope, eye/mask and jitter mode measurement capabilities on your PC. The powerful new software application provides offline and connected measurement capability for both the 86100C DCA-J and 86100D DCA-X oscilloscopes.

Data Sheet 2014-07-31

PDF PDF 205 KB
15431A Filter Set for 81150A - Data Sheet
The Agilent 15431A is a filter set for the 81150A. It generates the random jitter profile for testing PCI Express 2.0 receivers. To be used in conjunction with the N4903A.

Data Sheet 2014-07-31

PDF PDF 1.09 MB
86100CU-400 86100DU-400 PLL and Jitter Spectrum Measurement Software - Data Sheet
86100CU-Option 400 for the 86100C Infiniium Digital Communication Analyzer (DCA-J) is an advanced software application that makes fast, accurate, and repeatable phase locked loop (PLL)/jitter transfer measurements, using a precision jitter source and receiver.

Data Sheet 2014-07-31

86115D Multi-Port Plug-In Module for High-Volume/Parallel Optical Transceiver Test - Data Sheet
The 86115D is the ideal solution for high volume waveform analysis of transceivers operating, they Dramatically reduce the cost of test with high throughput test configurations

Data Sheet 2014-07-31

Understanding and Using Offset in InfiniiMax Active Probes - Application Note
This application note explains how offset is applied in the Keysight InfiniiMax Active Probes and how to use offset for various applications

Application Note 2014-07-31

Time Domain Reflectometry Theory - Application Note
When compared to other measurement techniques, time domain reflectometry provides a more intuitive and direct look at the DUT's characteristics.

Application Note 2014-07-31

Keysight L4610A PRM - 34B Radio Test Set - Brochure
Rugged, portable, radio test set provides true one-button operational testing of SINCGARS radios

Brochure 2014-07-31

PDF PDF 1.53 MB
3.35 GHz Pulse/ Pattern Generators - Promotional Flyer
The 81133a/34a is the first choice when timing and performance are vital. It is designed to enable R&D and test engineers to carry out tests more effectively, by providing access to necessary parameters.

Promotional Materials 2014-07-31

PDF PDF 1.31 MB
On-Wafer Testing of Opto-Electronic Components Using LCA's
This document describes the principles of on-wafer measurements on opto-electronic components

Application Note 2014-07-31

81133A and 81134A, 3.35 GHz Pulse Pattern Generators - Data Sheet
81133A and 81134A 3.35 GHz Pulse Pattern Generators. The need for pulse and pattern generation is fundamental to any device characterization task.The ability to emulate the pulse and pattern conditions to which the device will be subjected is essential.This emulation should include both typical and worst case conditions.Such accurate emulation requires superlative signal integrity and timing performance along with full control over parameters that allow specific worst case testing.

Data Sheet 2014-07-31

PDF PDF 1.41 MB
Understanding Oscilloscope Frequency Response & Its Effect on Rise-Time Accuracy - Application Note
In this application note, we review the properties of both Gaussian and flat-response oscilloscopes, then discuss rise time accuracy for each response type. We show that flat-response oscilloscope, give more accurate rise-time measurement than a Gaussian-response oscilloscope of equal bandwidth, and we show you how to estimate the bandwidth you need. The application note will show you which type of frequency response offers the best measurement accuracy; there are two issues to consider, the maximum signal frequency, and the oscilloscope sampling alias errors. It will also determine how much bandwidth you need.

Application Note 2014-07-31

86100D Option 201 Advanced Waveform Analysis Software - Product Fact Sheet
Keysight 86100C Option 201 Advanced Waveform Analysis Software. Option 201 offers breakthrough insights and faster standard compliance measurements such as Transmitter Waveform Dispersion Penalty (TWDP)

Data Sheet 2014-07-31

PDF PDF 1.25 MB
Introduces Industry's Most Accurate Test Solution for USB 3.1 Receivers
Achieve accurate receiver characterization with the J-BERT high-performance BERT

Press Materials 2014-07-09

User's Guides, Programmer's Guides, and Online Help (Version 04.60.0024)
This installer places an "Keysight Infiniium Docs" folder shortcut on your desktop. In this folder you can find user's guides, programmer's guides, and other manuals that go with Infiniium 90000 Series and 9000 Series oscilloscope system software.

Help File 2014-06-18

EXE EXE 239.71 MB
Jitter Analysis: The Dual-Dirac Model, RJ/DJ, and Q-Scale - Application Note
This paper provides a complete description of the dual-Dirac model, how it is used in technology standards and a summary of how it is applied on different types of test equipment.

Article 2014-06-14

PDF PDF 515 KB
Lightwave Tutorial Series on Complex Optical Modulation - Article
Keysight offers a tutorial series on complex optical modulation featured in Lightwave magazine, featuring for example the challenges of coherent signal detection.

Article 2014-05-22

Certification of HDMI 2.0 Test Solution
Certification of HDMI 2.0 Test Solution for HDMI 2.0 Compliance Test, With Widest Coverage of Test Items

Press Materials 2014-04-17

Infiniium 90000A Series Oscilloscopes - Data Sheet
The Infiniium 90000A Series oscilloscopes are engineered to give you unmatched real-time measurement accuracy. They are used in compliance testing in today's most popular serial bus standards.

Data Sheet 2014-04-16

Optical Modulation Analyzer New Analysis Software Demo - Video
This video gives you a brief overview of the key new features like smart setup and new measurements. In addition it describes briefly how to setup various hardware configurations.

Demo 2014-04-15

Essentials of Coherent Optical Data Transmission - Application Note
The Application Note explains how complex modulated optical signals can maximize bit transfer efficiency in fiber optical data transmission.

Application Note 2014-04-02

PDF PDF 3.03 MB
N4391A Optical Modulation Analyzer Security Features and Volatility Documentation – Reference Guide
This document describes instrument security features and the steps to declassify an instrument through memory sanitization or removal.

Reference Guide 2014-04-01

PDF PDF 133 KB
N4965A Multi-Channel BERT 12.5 Gb/s - User's Guide
The user's manual covers: setting up the system, operation, applications, performance specifications, remote operation, and warranty/product service.

User Manual 2014-04-01