Does Keysight Intuilink VNA operate with the 8753D Network Analyzer?
Only if the 8753D VNA is equipped with firmware revision 06.14 or revision 07.14

FAQ 2009-07-13

What is the login and password that I can use to login to the web server on the N1996A CSA spectrum analyzer?
See contents for details...

FAQ 2009-06-18

How Can I Save My Test Results to a PC?

FAQ 2009-06-11

How Can I Remotely Determine the Serial Number and Firmware Revision of My Test Set?

FAQ 2009-06-11

How do I save deep memory waveform data from my InfiniiVision oscilloscope to a USB storage device?
Use half-channel mode and ASCII XY, ALB, or BIN format. Within the "Save" menu, press Settings and select the max number of points. Make sure you are at a slow enough time/div setting that all the points are on screen, and then ...

FAQ 2009-05-03

Is there an example program for acquiring data from the Keysight 8970B Noise Figure meter via the GPIB bus?
Vee program found here...

FAQ 2009-04-28

How do I connect my InfiniiVision oscilloscope directly to a PC via the LAN interface?
To establish a point-to-point LAN connection, you will need either a PC with an Auto-MDIX network adapter or a crossover (not straight-through) LAN cable.

FAQ 2009-04-23

Are there any SCPI programming commands available for the U2701A/2702A USB Modular Oscilloscope instrument control?
No, there are no SCPI commands available for the U2701A/2702A USB Modular Oscilloscope….

FAQ 2009-04-21

Where can I find the U2701A/U2702A IVI-driver's programming reference guide?
The U2701A/U2702A IVI-driver's reference guide is in "Documentation" in the Keysight IVI driver folder upon completion of driver installation

FAQ 2009-04-21

Are there any programming commands for the U2701A/U2702A USB Modular Oscilloscope?
Yes, the IVI driver is available for the U2701A/2702A USB Modular Oscilloscope instrument control….

FAQ 2009-04-21

Can I convert a 16500-series logic analyzer configuration to a 16900-series logic analyzer configuration?
Yes, for selected modules.

FAQ 2009-03-30

Why Can’t I Open the BenchLink II AgtDB.mdb Database File in Microsoft® Access?
The file is password protected to prevent any changes to be made to the file.

FAQ 2009-03-13

Can the IBasic option be retrofitted on the Keysight E5100A/B Analyzers?
Unfortunately, for those E5100A/Bs ordered with option UKR (delete internal IBasic) there is no retrofit to reinstall IBasic in the instrument.

FAQ 2009-03-12

When I print the 35670A trace display to the raster printer connected to the analyzer, why am I getting a smaller printout?
On the 35670A, the work-around for this is as follows...

FAQ 2009-03-12

Are the GPIB commands of the 4287A compatible with the 4286A?

FAQ 2009-03-11

Do the 4284A GPIB commands comply with SCPI?
Yes. The GPIB programming language of the 4284A is SCPI.

FAQ 2009-03-11

Is it possible to create a VBA, LabVIEW or any control program for application and run it on the 4287A?

FAQ 2009-03-11

Can I use any instrument driver software for the 4284A?
National Instrument’s LabVIEW driver supports the 4284A.

FAQ 2009-03-11

When using a U2701A/U2702A USB Modular Oscilloscope, what is the maximum data point of the waveform that I can save ?
When using a U2701A/U2702A USB Modular Oscilloscope, you can save a maximum of 2000 data points for a single channel measurement….

FAQ 2009-02-11

Is the Keysight Intuilink PNA application supported while the analyzer's frequency offset mode (option 080) is activated?
Keysight Intuilink PNA is not supported when the analyzer is in the frequency offset mode.

FAQ 2009-02-10

How can I access to the maximum memory depth (32M/16M) as stated in the U2701A/U2702A Modular Oscilloscope's data sheet?
You can see the effects of maximum memory depth 32/16 Mpts in zoom mode….

FAQ 2009-02-04

Can open/short/load correction data be entered in the 4285A from an external PC over GPIB?

FAQ 2009-01-14

How can I clear an error message shown on the display of the 4294A/4395A/4396B by using GPIB command?
Send the "KEY 18" command to the instrument.

FAQ 2009-01-08

Can I use any instrument driver software for the 4285A?

FAQ 2009-01-08

Can the time stamp function and :LIST:SEQuence:TSTamp:DATA command of the E4980A be used for a list sweep measurement in STEP mode?
No, the time stamp function can be used in the sequential (SEQ) mode only.

FAQ 2009-01-08