Here’s the page we think you wanted. See search results instead:

 

Hable con un experto

Technical Support

Electronic Measurement

Support by Product Model Number:

1-25 of 128

Sort:
Does Keysight VEE 9.0 support Windows 7?
Yes. A Keysight VEE patch is currently in development and is tentatively scheduled for release on 2nd quarter of 2010.

FAQ 2013-11-17

How do I remotely program my spectrum or vector signal analyzer?
Instructions, examples, and references for remotely programming your spectrum analyzer

FAQ 2013-05-16

What is the frequency range of the N5532B Sensor Module?
100 kHz to 4.2 GHz, 10 MHz to 18 GHz, 30 MHz to 26.5 GHz, and 30 MHz to 50 GHz.

FAQ 2012-02-26

How do I include Mismatch Uncertainty into the N5531S Measuring Receiver Absolute Amplitude accuracy?
The N5531S Measuring Receiver System is comprised of a PSA Series Spectrum Analyzer with Option 233 (measuring receiver personality), a P-Series or an EPM Series Power Meter, and an N5532B (or N5532A) Sensor Module.

FAQ 2012-02-26

What is the frequency coverage of the N5532A/N5532B sensor module? What options would my PSA Analyzer require to operate in an N5531S?
The N5532A/N5532B is offered in four optional frequency ranges. All models can measure power from -20 dBm to +30 dBm.

FAQ 2012-02-26

What is the frequency range of the N5532A Sensor Module?
100 kHz to 4.2 GHz, 10 MHz to 18 GHz, 30 MHz to 26.5 GHz, and 30 MHz to 50 GHz.

FAQ 2012-02-26

Does the ENA support 87050E / 87075C series multiport test sets?
Unlike the E5061A and E5062A, the E5061B, E5071C and E5072A (ENA) does NOT support full functions of 87050E / 87075C. But it is possible to change switch state of 87050E-Hxx / 87075C-Hxx via GPIB.

FAQ 2012-01-11

Is there an outline for configuring my HP Basic to communicate with the Keysight ENA analyzer via SCPI-LAN?

FAQ 2011-10-07

What is EVO and what are the known issues?
EVO is an abbreviation for Extensible VEE Object, which introduce after VEE Pro Version 9.21

FAQ 2011-03-31

How do I control instruments such as 82357A, E5810A, and 82350B using the GPIB interface?
There are several approaches to control instruments via the GPIB interface...

FAQ 2010-10-04

VEE Pro: Why can't I talk to an instrument at GPIB address 21?
The reason is that each device on the GPIB has to have a unique address, including the computer's GPIB card.

FAQ 2010-09-09

IO Libraries Suite: Where do I find sample programs for SICL, VISA, and VISA COM?
Sample programs are available using SICL, VISA, and VISA COM in the IO Libraries Suite installation and on Keysight.com

FAQ 2010-09-08

How can I make NI LabVIEW communicate with my 82357A USB/GPIB Interface?
Install the IO libraries Suite and configure the 82357A. There may be other configuration steps if you install NI-VISA.

FAQ 2010-08-30

Can the measurements taken be read from the 34980 Data Acquisition Front Panel?
No

FAQ 2010-05-14

Can I program a waveform captured by my oscilloscope into a Keysight arbitrary waveform generator?
Yes. The free IntuiLink Waveform Editor software will download waveform data from Keysight Infiniium, 6000 series, and 54600 series oscilloscopes and send the data to the a Keysight 33120A, 33210A, 33220A, or 33250A generator.

FAQ 2010-05-14

When sending a "*IDN?" query to the 8156A optical attenuator over GP-IB why does the instrument return the string "8157A..."?
The 8156A has two command sets for programming over GP-IB. The first is the 8156A command set and the second simulates the command set of a previous optical attenuator, the 8157A.

FAQ 2010-05-14

Is VEE able to interpret "," as decimal point in Formula box running under German Windows?
No. Please use "." as decimal point as per international standard.

FAQ 2009-11-17

Why did VEE displayed an "out of memory" message even the PC has more than 1GB of memory free after using up only 300MB of memory?
Keysight VEE's could not support such a large memory of usage in a single object or interface.

FAQ 2009-11-08

IO Libraries Suite: Is there any other software that needs to be installed when I am using an application that utilizes NI-488.2 and Keysight IO Lib...
It depends if there is third party connectivity hardware or software installed.

FAQ 2009-08-25

IO Libraries Suite: What programming languages are supported with Keysight IO Libraries version 15.1?
It depends on the API you are using.

FAQ 2009-08-25

How do I transfer files to and from my 1660/1670-series logic analyzer using FTP?
To transfer files to and from 166xE and 167xA/D/E/G logic analyzers using FTP, follow these steps.

FAQ 2009-07-16

How Can I Save My Test Results to a PC?

FAQ 2009-06-11

How Can I Remotely Determine the Serial Number and Firmware Revision of My Test Set?

FAQ 2009-06-11

Is there an example program for acquiring data from the Keysight 8970B Noise Figure meter via the GPIB bus?
Vee program found here...

FAQ 2009-04-28

When I print the 35670A trace display to the raster printer connected to the analyzer, why am I getting a smaller printout?
On the 35670A, the work-around for this is as follows...

FAQ 2009-03-12