Does the E1432A or E1433B have external sampling capability?
The E1432A and E1433B does indeed have an EXTERNAL SAMPLE input.

FAQ 2002-09-12

Can the E8491B VXI-Firewire interface be used in multiple-card cage configurations?
The E8491B can be used in multiple-card cage systems. There are, however, certain limitations.

FAQ 2002-08-14

8901A, 8901B Group Delay Measurements, Envelope Delay
Here is some information on group delay of the 8901, which should help to locate the phase change vs frequency between a signal generator and a modulation analyzer.

FAQ 2002-06-27

892NX Spectrum Analyzer Sweep Time and Resolution Bandwidth Range

FAQ 2002-06-27

71210C: DANL comparison to 71200C

FAQ 2002-06-27

8922 FAQ: GPIB OPOS Command

FAQ 2002-06-27

E1445A Sine Wave Limitation Using ARM:LAY1:COUNT

FAQ 2002-06-27

8903B, SINAD Measurement, Average and RMS Detectors

FAQ 2002-06-27

8566A and 8566B Spectrum Analyzer Frequency Bands

FAQ 2002-06-27

859xE: Why Does the Signal Level Change Depending on the Setting of the Input Attenuator?

FAQ 2002-06-27

Why Can't My 8922 Measure Audio Frequency Anywhere Near the 400kHz Quoted in the Spec's?

FAQ 2002-06-27

Keysight 8901B External LO Setup and 25 kHz Offset Phase Noise Measurements

FAQ 2002-06-27

Why Does the 11807E Option 024 Software Change My Vocoder Setting?

FAQ 2002-06-27

Why Doesn't the Keysight 8920A,B Power My Phone?

FAQ 2002-06-27

859xE: Why Does a Power Meter Show the CAL OUT Power to Be 2-3dB Higher Than Specified?

FAQ 2002-06-27

8901, 8902 FM Accuracy, Track Versus Standard Mode

FAQ 2002-06-27

Debugging Hints for a Keysight 3852A Control System

FAQ 2002-06-27

8902A TRFL in Avg Mode and Noise Correction Problem

FAQ 2002-06-27

What is the function of the E8480A "Emergency Reset"?

FAQ 2002-06-27

89400: 12Vdc Inverter Manufacturer

FAQ 2002-06-27

8902A, Operation Up To 110 GHz

FAQ 2002-06-27

8901A, 8901B Power Meter and AM, FM Calibrators
If the unit is left powered up and the temperature is stable, calibrating once a week is no problem, and calibrating once a month may be possible if nothing happens to the power sensor like over power or mechanical shock.

FAQ 2002-06-27

8901B LO Feedthrough out the RF Input Port

FAQ 2002-06-27

892NX Spectrum Analyzer Demodulated Audio

FAQ 2002-06-27

Keysight 8922: The power meter and making RF power measurements.

FAQ 2002-06-27

Previous 1 2 3 4 5 6 7 8 9 10 ... Next