Battery Temperature Profiling While Charging and Discharging - Application Note
Temperature profiling is crucial as the charging and discharging rate of battery-powered devices inadvertently heats up the batteries. Here are ways to perform this task efficiently and effectively.

Application Note 2017-08-17

PDF PDF 2.44 MB
L4490A/L4491A RF Switch Platform User’s and Service Guide
Includes switch and attenuator installation, configuration, and programming information.

User Manual 2017-07-28

PDF PDF 9.77 MB
Using BenchVue to Create and Execute Scan Lists on 3497xA Data Acquisition Units - Application Note
Lean how Keysight's BenchVue software can be used with 3497xA data acquisition units to easily create state information, quickly build automated tests drive measurements to actionable insights faster.

Application Note 2017-07-03

PDF PDF 1.43 MB
GPIB, USB and Instrument Control products - Data Sheet
Choose the best way to connect your PC to current instruments and take advantage of PC-standard interfaces. This family data sheet will give you the information you need to know about Keysight's I/O hardware products.

Data Sheet 2017-06-15

Make Better AC RMS Measurements with Your Digital Multimeter - Application Note
learn about the complexity of ac rms measurements and how to deal with them

Application Note 2017-06-12

U2300A Series USB Modular Multifunction Data Acquisition Devices - Data Sheet
This is the datasheet for the U2300A Series USB modular multifunction data-acquisition devices which offer a high performance PC data-acquisition solution.

Data Sheet 2017-06-01

PDF PDF 582 KB
Essential Components of Data Acquisition Systems (AN 1386)
To help you choose a system that meets your needs, this article gives an overview of the components that make up the typical data acquisition system and examines some of the advantages and disadvantages of the different component types and configurations.

Application Note 2017-05-22

Achieve Accurate Resistance Measurements with the Keysight 34980A Multifunction Switch Measure Unit
This application note provides an overview of how to make an accurate 2-wire, 3-wire and 4-wire resistance measurements with the Keysight 34980A

Application Note 2017-05-16

How to Characterize a DC-DC Converter Using a DAQ and BenchVue Software - Application Note
This application note provides an easy, step-by-step approach for measuring and plotting several characteristics of a DC-DC converter using Keysight’s 34970A/72A DAQs with BenchVue software.

Application Note 2017-05-04

PXI Digital Multimeters, 61/2 Digit, High Performance (M9182A, M9183A) - Data Sheet
These 61/2 digit DMMs offer excellent accuracy & stability with the highest measurement speeds in their class. For Engineers using PXI test systems in A/D, electronic mfg. & the automotive industries.

Data Sheet 2017-05-03

IO Libraries Minimum System Requirements - Technical Overview
Computer hardware and operating system minimum requirements for using Keysight IO Libraries Suite.

Technical Overview 2017-03-22

PXI / AXIe / DAQ & Modular Solutions - Technical Support

Demo 2017-03-19

Migrating to the Latest Keysight Software for the 34972/70A Data Acquisition Units - Migration Guide
Provides a comparison of various data acquisition software.

Configuration Guide 2017-03-19

PDF PDF 488 KB
M9157C and M9157CH40 PXI Hybrid Single SP6T Switch 3D, STEP Format
This is STEP format 3D Model of the M9157C and M9157CH40

Technical Overview 2017-03-10

ZIP ZIP 2.40 MB
M9156C and M9156CH40 PXI Hybrid Dual Transfer Switch 3D model, STEP Format
This is STEP format 3D Model of the M9156C and M9156CH40

Technical Overview 2017-03-10

ZIP ZIP 2.05 MB
M9155C and M9155CH40 PXI Hybrid Dual SPDT Coaxial Switch 3D model, STEP Format
This is STEP format 3D Model of the M9155C and M9155CH40 PXI Hybrid Dual SPDT Coaxial Switch

Technical Overview 2017-03-10

ZIP ZIP 1.98 MB
PXI & AXIe Instruments, Software, Reference Solutions and Services - Brochure
This brochure provides an overview of Keysight's PXI & AXIe instrument, software, solutions and services offering.

Brochure 2017-02-27

PDF PDF 2.34 MB
Optimize your wideband test solution
download new application note: Optimize your wideband test solution

Application Note 2017-02-21

PXI General Purpose Switch Module - Data Sheet
The PXI general purpose switch module data sheet provides specifications and product ordering information for M9130A, M9131A, M9132A, M9133A, and M9135A.

Data Sheet 2017-01-31

PXI Multiplexer Switch Module - Data Sheet
The PXI multiplexer switch module data sheet provides specifications and product ordering information for M9101A, M9102A and M9103A

Data Sheet 2017-01-30

[ECU Testing] Perform Automatic Input/Output Static Characteristics Tests on the Bench
Ever wanted an automatic manufacturing test environment for design evaluation?

Brochure 2016-12-28

PDF PDF 482 KB
U2300A Series User’s Guide
User’s guide for the U2300A Series Multifunction USB Data Acquisition. Contains a description of the features and functions of the instrument, including programming information, application examples, and technical specifications.

User Manual 2016-12-02

Keysight M9155/6/7C PXI Coaxial Switches and M9161D PXI Solid State Switch
Installation, verification, service and maintenance for M9155/6/7C and M9161D

User Manual 2016-11-25

PDF PDF 781 KB
Quarterly Basic Instruments Flyer
Keysight’s essential instruments for every engineer. Are you building a general purpose bench? Start here to see our solution set for fundamental measurements and device characterization. Flyer spotlights a new tip or technology each quarter.

Brochure 2016-10-26

PDF PDF 1.42 MB
Maximizing Battery Life of IoT Smart Devices with Keysight Solutions - Application Brief
This application brief details the design and test challenges involved with maximizing the battery life of Internet of Things (IoT) smart devices, and recommends Keysight solutions to address them.