What is the purpose of the grounding lead of the 16048D?
The grounding lead of the 16048D is used to interconnect this shielding conductor and the ground terminal on LCR meter's front panel.

FAQ 2009-01-13

What compensation should I perform when I use the 16048B with the 4285A?
It is recommended to set the Cable Length function of the 4285A to "1 m" and perform open/short/load compensation at the DUT contact terminals of the test fixture connected to the tip of the 16048B.

FAQ 2009-01-13

How can I get a 0603 size LOAD standard that can be used to perform LOAD correction using the 16196C and other SMD test fixtures?
Keysight part number 0699-6926 can be used as a LOAD standard. It is a 51-ohm chip resistor.

FAQ 2009-01-13

What are the differences between the 16048A and the 16048D?
The differences between the 16048A and 16048D are shown in the table below...

FAQ 2009-01-13

How do I connect the 16048G 1m BNC connector leads to the 16452A?
You need four BNC(m) to BNC(m) adapters (Keysight part number 1250-0216) to connect the 16048G to the 16452A.

FAQ 2009-01-12

Is the collet (center contact) of the 16454A identical to that of the 42942A (part number 1250-0907)?
Yes, When replacing the collet (center contact) of the 16454A, you can use the same part (part number 1250-0907) as that used in the 42942A.

FAQ 2009-01-12

There are 4 types of spacers for the 16452A. Is there any criterion for selecting the spacer?
There is no specific criterion for the selection except that the 1.3 mm spacer is required for the short compensation.

FAQ 2009-01-12

What is the maximum hydraulic pressure applicable to the 16452A?
Any pressure in excess of 1 atm (atmosphere) should not be applied to the 16452A.

FAQ 2009-01-12

Can I use the 42842C with the 4284A and the 42841A?
No, you can't. The 42842C is not designed to be used with the 4284A. The 42842C can only be used with the 4285A

FAQ 2009-01-12

Does the part number 16334-09002, which is described in the 16334A operation and service manual, indicate one unit of the part?
Yes, the part number 16334-09002 indicates one unit of the part.

FAQ 2009-01-12

What is the part number of the tweezers contact tip used in the 16334A?
The contact tweezers tip is Keysight part number 16334-09002. A single 16334A requires two of the 16334-09002 tips.

FAQ 2009-01-12

Why is the capacitance measured for a liquid material with the 16452A unstable?

FAQ 2009-01-12

How can I get a 0603 size LOAD reference device that can be used to perform LOAD correction using the 16197A and other SMD test fixtures?
A 51-ohm chip resistor (Keysight part number 0699-6926) can be used as a LOAD device.

FAQ 2009-01-12

Why is the capacitance measured for an air-dielectric with the 16452A unstable?
If the capacitance measured for an air-dielectric is unstable, check whether the 16452A electrodes are sufficiently clean or not.

FAQ 2009-01-12

What accessories can be used for the 4396B?
Please refer to "Available Accessories" section in the 4396B Configuration Guide.

FAQ 2008-11-17

What is the recommended part for the signal injection transformer which is required for switch-mode power supply test using the 4395A?
Keysight part number 5188-4425 transformer is recommended.

FAQ 2008-11-16

Are there any balun transformers that can be used with the 4395A?
Yes.

FAQ 2008-11-16

What accessories can I use with the 4395A?
Please refer to "Available Accessories" section in the 4395A Configuration Guide.

FAQ 2008-11-16

Can I use the 1141A 200 MHz Differential Probe with the 4395A?
Yes, but you need to use the 1142A Probe Control and Power Module along with the 1141A in order to supply a DC operating power and control some input functions of the 1141A.

FAQ 2008-11-16

Can I use the 35677A (S-Parameter Test Set for the 3577A/B) for the 4395A?
No, the 4395A can't control the 35677A. The 35677A can be used only for the 3577A/B. Recommended S-parameter test set for the 4395A is 87511A/B.

FAQ 2008-11-16

Is there any ID to discriminate incompatible USB memory from E4980A compatible ones?
See the following ID of incompatible USB memory devices.

FAQ 2008-11-12

What is the part number of pull-up resistors recommended for the option E4980A-201 handler I/F of the E4980A?
Recommended resistance values and part numbers of the pull-up resistors are shown in the following table.

FAQ 2008-11-12

How should the short compensation be performed when the pin-type probes (Part Number 16006-60001) of the 16338A are used with the 4338B?
Basically, the short compensation should not be performed when the pin-type probes are used. It is difficult to properly short the contact pins at the tips of pin-type probes.

FAQ 2008-11-12

Is the E4980A compatible with all the test fixtures which can be used with the 4284A?
Yes, all the test fixtures available for the 4284A can be used with the E4980A.

FAQ 2008-11-12

What is the size (dimensions) of E4980A-1CM rack mount kit?
The rack mount kit consists of a small bracket and a large attachment panel for installing the E4980A in a 19-inch standard rack as follows.

FAQ 2008-11-12