Hable con un experto

Technical Support

Oscilloscopes

Find by Product Model Number: Examples: 34401A, E4440A

Refine the List

remove all refinements

By Type of Content

By Product Category

1-10 of 10

Sort:
86100D Option 201 Advanced Waveform Analysis Software - Product Fact Sheet
Keysight 86100C Option 201 Advanced Waveform Analysis Software. Option 201 offers breakthrough insights and faster standard compliance measurements such as Transmitter Waveform Dispersion Penalty (TWDP)

Data Sheet 2014-07-31

PDF PDF 1.25 MB
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet
The 86100D DCA-X performs precision measurements on high-speed digital designs from 50Mb/s to more than 80Gb/s.

Data Sheet 2014-07-08

Techniques to Reduce Manufacturing Cost-of-Test of Optical Transmitters
Pressures to reduce costs as data rates rise means manufacturing engineering managers and their engineers must be more creative in how to reduce costs before their competitors do.

Application Note 2011-12-22

Techniques to Reduce Manufacturing Cost-of-Test of Optical Transmitters, Flex DCA Interface
Keysight continues innovating test methodologies to assist manufacturing engineers in meeting or beating cost-of-test reduction goals.

Application Note 2011-12-22

N1010A FlexDCA Virtual Device Demonstration
N1010A FlexDCA Virtual Device Demonstration Video This 3 minute video shows how to help sell high-speed semiconductors using the N1010A FlexDCA.

Product Tour 2011-11-01

De-embedding demo using InfiniiSim-DCA
This 7 minute video documents a de-embedding measurement using InfiniiSim-DCA for the 86100C DCA-J

How-To Video 2011-11-01

WMF WMF 38.44 MB
Lowest Cost of Optical Transceiver Test
Explore major cost of test reduction ideas using the Eye Mask Hit Ratio Technique and the Auto Mask Margin function. Achieve dramatic efficiency improvement in optical transmitter eye-mask testing.

Product Tour 2011-11-01

Techniques for Higher Accuracy Optical Measurements
Learn techniques for high accuracy optical measurements using System Impulse Response Correction

Application Note 2011-09-21

86100D DCA-X Overview
This 5 minute video provides an overview of the 86100D DCA-X wide-bandwidth oscilloscope.

Product Tour 2010-06-16

WMF WMF 12.74 MB
Equalization: The Correction and Analysis of Degraded Signals
This whitepaper introduces engineers to the concepts of equalization and terms used in the development of emerging technologies that use standard materials (e.g., FR4) for buses and backplanes at ever higher rates.

Application Note 2005-09-15

PDF PDF 1.41 MB