Contact an Expert

Technical Support

Electronic Measurement

Find by Product Model Number: Examples: 34401A, E4440A

26-50 of 74

Sort:
DC-to-DC Regulator Auto Evaluation Test with the U2351A
The Keysight U2351A data acquisition (DAQ) is used as an automatic DC voltage regulator and to induce voltage into the electronics system thereby causing an amount of under voltage or over voltage stress to the device under test (DUT).

Application Note 2009-02-04

PDF PDF 270 KB
Application Note: Tips & Tricks for Using USB, GPIB, & LAN (AN 1465-20)
Application Note: Tips & Tricks for Connectivity

Application Note 2009-01-22

Simplified PC Connections for GPIB Instruments (AN 1409-1) - Application Note
Making the connection from your instruments to your PC has not always been an easy task. Today there are new choices that allow for easier connections so that you can focus on your measurement tasks and not on your connections. This paper will walk you through the choices you need to make when...

Application Note 2009-01-22

High-Speed Scanning with the Keysight 34980A Multifunction Switch/Measure Mainframe and Modules
This application note explores components that affect the speed in a system. It also gives a breakdown of each component with SCPI language examples of how to set up the instrument for fast measurements that best fit your specific application.

Application Note 2008-11-26

Boosting PLL Design Efficiency From free-running VCO characterizations to closed-loop PLL evaluation
This application note describes introduces practical solutions for VCO/PLL performance evaluation and gives actual examples of parameter measurements using the E5052B.

Application Note 2008-11-21

Responding to data logging events using action scripts
Combining data logging hardware and software can give you more techniques to automate extensive and repetitious measurements.

Application Note 2008-10-30

Improve your data logging productvity using advanced limit testing
Improve your data logging productvity using advanced limit testing

Application Note 2008-10-30

PDF PDF 456 KB
DVD Player Manufacturing Test Using Keysight Modular Instruments
Audio and video testing of modern digital video disc (DVD) player using Keysight’s USB modular oscilloscopes and USB modular switch matrix.

Application Note 2008-09-15

Using USB and LAN I/O Converters - Application Note
Compare 3 instrument connectivity products to determine which interconnect device is best for your application needs.

Application Note 2008-07-09

PDF PDF 194 KB
Automotive Power Window Regulator Testing - Application Note
Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters such as window movement, acceleration of the window movement in both directions, maximum range of movement, torque exerted at the start, the end stall torque, and motor load characteristics.

Application Note 2008-06-30

PDF PDF 280 KB
Small Engine Dynamometer Testing - Application Note
Performing Dynamometer Testing on Combustion Engines

Application Note 2008-06-01

PDF PDF 443 KB
Testing Electromagnetic Compatibility of Remote Keyless Entry Modules in Automotive Applications
One of the most widely used electronic systems is remote keyless entry (RKE). Many manufacturers are expanding the capabilities of the RKE modules being used in the latest automobiles. With increased module functionality, there is also a need for increased test coverage because an RKE module may be used to perform multiple tasks, from unlocking car doors to remotely starting a car’s engine.

Application Note 2008-04-01

PDF PDF 110 KB
Creating a Small, Low-cost RF Switching System using U2121A based solution
Creating a Small, Low-cost RF Switching System using U2121A based solution. This digital I/O module provides a cost-effective alternative for small test systems.

Application Note 2008-03-18

PDF PDF 271 KB
Automated Handler Machine for Test System Using Keysight U2100A DIO
This application note describes how the Keysight U2100A DIO is used for machine automation.

Application Note 2007-11-14

PDF PDF 342 KB
PMU Troubleshooting Using U2531A Simultaneous Data Acquisition
This application note describes how PMU troubleshooting can be performed using the U2500A Series Simultaneous Sampling DAQ.

Application Note 2007-11-14

PDF PDF 158 KB
Strain Measurement Application Using U2300A Series with Keysight VEE Pro - Application Note
This application note describes how users can make strain and vibration measurements using the Keysight USB DAQ for reliability and strength characterization of concrete and metal structures.

Application Note 2007-05-18

PDF PDF 208 KB
How Operating Life and Repeatability of Keysight’s EM Switches Minimize System Uncertainty
This application note discusses the effects of operating life and repeatability on coaxial electromechanical switches.

Application Note 2007-04-09

Power Handling Capability of Electromechanical Switches
This application note discusses the power handling of the hot switching and cold switching of EM switches.

Application Note 2007-03-05

Standardized Core Makes Building and Supporting a Functional Test System Easier and Less Costly
This note demonstrates how to use LXI instruments to create a standardized core - the open test platform (OTP), for building test systems.

Application Note 2007-02-23

How to Verify the Functionality of Your 34980A Switch Modules
This application note outlines the benefits of the Y1131A and demonstrates its effectiveness using a 34980A multifunction switch/measurement unit.

Application Note 2006-11-06

PDF PDF 220 KB
Optimizing Test Systems for Highest Throughput, Lowest Cost and Easy LXI Instrument Integration
A new class of LXI instruments can save rack space, money and integration time over PXI. This application note discusses the tradeoffs and also explains how to optimize execution time through careful use of SCPI to avoid LAN latency issues.

Application Note 2006-03-23

Optimizing Test System Throughput, Cost and Integration Time Using LAN-Based Instruments
This application note explains how to minimize latency when using LAN to control your instrumentation and explains why LAN is an excellent choice for cost savings and ease of integration.

Application Note 2006-01-09

LAN Connection using Telnet
When communicating with a LAN instrument using TELNET, do the following...

Application Note 2005-06-29

Optimizing Thermocouple Measurement Accuracy With the Keysight 34980A
The 34921A/34921T is currently the only multiplexer module for the 34980A that provides an isothermal reference and temperature sensor for thermocouple measurements on the terminal block...

Application Note 2005-04-12

Moving from the HP 3852A Data Acquisition System to the Keysight 34980A Switch/Measure Unit
This application note describes the migration path of the HP 3852A data acquisition product to the new Keysight 34980A switch/measure unit; scanning versus matrix switches.

Application Note 2005-04-05

PDF PDF 137 KB

Previous 1 2 3 Next