Creating and Optimizing 802.11ac Signals Application Note
This application note details how to create and optimize 802.11ac signals using the N7617B Signal Studio for WLAN 802.11a/b/g/n/ac software with Keysight's RF signal generators to get the highest quality signals from the instruments.

Application Note 2012-07-19

PDF PDF 2.10 MB
Spectrum and Signal Analysis Pulsed RF Application Note 150-2
This application note is intended as an aid for the operation of spectrum and signal analyzers and the interpretation of the displayed pulse spectra.

Application Note 2012-07-05

Testing a Low-Noise Block Downcoverter-Feedhorn Application Note
This application note provides an example of a LNBF test configuration using a CXA signal analyzer and illustrates how easy it is to perform tests and make measurements.

Application Note 2012-07-05

PDF PDF 2.05 MB
Conducting Site Surveys Using the N934xC Series Handheld Spectrum Analyzers
This brief application note explains how the N9344C, N9343C, and N9342C handheld spectrum analyzers are an effective tool for measuring signal strength and performing a site survey.

Application Note 2012-06-01

Spectrum and Signal Analyzer Measurements and Noise Application Note 1303
Noise is the classical limitation of electronics. In this application note, the characteristics of noise and its direct measurement are discussed in detail.

Application Note 2012-05-04

Microwave and Millimeter Signal Measurements: Tools and Best Practices Application Note
Accurate microwave and millimeter frequency signal measurements are important in many applications. This note will help you make the right choices and steps to get accurate, reliable measurements.

Application Note 2012-04-26

Optimizing Performance and Cost for Millimeter Wave Signal Analysis - Application Note
This application note discusses recent advances in millimeter wave signal analysis and instrumentation that can be optimized for "just enough" performance versus cost.

Application Note 2012-04-18

PDF PDF 559 KB
Making Wideband Measurements - Application Note
This paper will discuss using the Keysight PXA signal analyzer as a microwave down converter for an Infiniium oscilloscope or Acqiris digitizer running the 89600 VSA software.

Application Note 2012-01-24

EMI Pre-Compliance Testing - Application Note
X-Series signal analyzers with the EMI measurement application offer a cost-effective pre-compliance testing solution.

Application Note 2012-01-16

PDF PDF 1.32 MB
10 Hints for Making Successful Noise Figure Measurements (AN 57-3) - Application Note
This document will help minimize the uncertainties in your noise figure measurements. Key topics include minimizing extraneous signals, mismatch uncertainties, nonlinearities, and path losses.

Application Note 2011-12-21

Evaluating Fluorescent Lighting Interference on Passive UHF RFID Systems
This paper highlights how the use of N934xC handheld spectrum analyzers are an effective way to determine if the effects of fluorescent lighting is impacting an RFID system

Application Note 2011-11-30

Optimizing Dynamic Range for Distortion Measurements
This Product Note covers high dynamic range measurement techniques for the new PSA Performance Spectrum Analyzer Series. The Note describes the best way to use the PSA series to make distortion measurements such as ACP, intermodulation, and harmonic distortion.

Application Note 2011-10-27

PDF PDF
Wireless Keyboard and Mouse Testing Made Easy - Application Note
Application note on wireless mouse and keyboards using the Keysight N9320B RF spectrum analyzer.

Application Note 2011-10-25

PDF PDF 2.21 MB
Interference Testing with Handheld Spectrum Analyzers - Application Note
This application note describes the techniques and procedures for interference testing in a wireless environment using the Keysight family of N934xC/N9340B handheld spectrum analyzers.

Application Note 2011-10-11

Procedures to Verify and Locate Interference Application Note
This application note looks at the process and techniques for measuring, verifying and locating wireless interference using the portable N934xC handheld spectrum analyzers.

Application Note 2011-10-11

Interference Classifications and Measurement Application Note
This paper defines the various types of interference and explains how the use of N934xC handheld spectrum analyzers are used to quickly identify the type of interference for quick resolution.

Application Note 2011-10-11

Gaining Deeper Insights into Dynamic BTS/UE Signals with WLA
This application note introduces link operation, wireless link analysis, a graphical approach to WLA, dynamic measurements, and additional capabilities specific to the analysis of LTE devices.

Application Note 2011-10-04

PDF PDF 214 KB
Optimizing Oscilloscope Measurement Accuracy on High-Performance Systems with Keysight Active Probes
This application note covers the following information that you should consider when selecting an oscilloscope probe to capture high-speed signals: Consider the effect that probe input impedance will have on your circuit. Capacitive loading becomes increasingly important at high frequencies and it is important to use the shortest possible ground lead to minimize inductance. The probe will introduce distortion into your measurements unless it has a flat transmitted response throughout the bandwidth of the probe. A flat transmitted response will closely track the signal at the probe tip and pass it to the oscilloscope with minimal degradation.

Application Note 2011-05-20

Infiniium Oscilloscopes Performance Guide
Infiniium Link to 89601A Software, Performance Guide.

Application Note 2011-03-31

Making EMI Compliance Measurements
This application note provides an overview of EMI compliance test requirements and measurement approaches.

Application Note 2011-03-09

Streamlining Field Test with Task Planner
For use with Keysight N9344C/43C/42C handheld spectrum analyzers (HSAs)

Application Note 2011-02-25

IEEE 802.16e WiMAX OFDMA Signal Measurements and Troubleshooting, AN 1578
This note provides a broad overview of measurement and troubleshooting approaches for OFDMA signals, and is not limited to digital demodulation or modulation quality analysis.

Application Note 2011-02-17

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T
The technology used in these ports, commonly known as “LAN” or “NIC” ports, is usually one of the 10BASE-T, 100BASE-TX, and 1000BASE-T standards or a combination of them.

Application Note 2011-01-11

Custom OFDM Signal Generation Using SystemVue - Application Note
This application note describes a new comms standard based on OFDM which is provided by SystemVue 2011 to create both simulation and measurement, with links to the new 89600B VSA software for further demodulation and analysis.

Application Note 2010-12-09

Fundamentals of RF and Microwave Noise Figure Measurements - Application Note
This 32-page, black-and-white application note providesinformation on RF and Microwave noise figure measurementts. Topics include noise figure and temperature, noise characteristics of two-port networks, and the measurement of noise figure.