SATA II Drive TX/RX Testing & Cable SI Testing Using the 86100C DCA-J - Technical Overview
SATA II Drive Tx/Rx Testing & Cable SI Test using 86100C DCA-J. Product Note 86100-8

Application Note 2014-08-02

PDF PDF 1.94 MB
Evaluating Oscilloscopes to Debug Mixed-Signal Designs - Application Note
Discusses the number of channels, bandwidth, sample rates and triggering required to effectively monitor various analog and digital I/O signals in typical MCU/DSP-based embedded designs.

Application Note 2014-08-01

FlexRay Physical Layer Eye-diagram Mask Testing - Application Note
Keysight provides seven different FlexRay mask files based on FlexRay physical layer standards/specifications for use with InfiniiVision 5000, 6000, and 7000 Series oscilloscopes (DSO or MSO)from Agilent.

Application Note 2014-08-01

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details - Application Note
The quality of your oscilloscope’s display can make a big difference in your ability to troubleshoot your designs effectively.

Application Note 2014-08-01

Finding the Cause of an Infrequent Glitch Using the InfiniiVision 6000 X-Series - Application Note
This application note is a supplement to “Finding the coupling signal that causes the glitch”a built-in and automatic demonstration on the Keysight InfiniiVision 6000 X-series.

Application Note 2014-04-29

PDF PDF 1.92 MB
Characterizing CAN Bus Arbitration - Application note
This app note will explain the CAN non-destructive bit-wise arbitration process. The InfiniiVision 4000 and 6000 X-Series oscilloscopes show examples of triggering and decoding those messages.

Application Note 2014-04-28

PDF PDF 1.23 MB
Evaluating Oscilloscope Bandwidths for Your Application - Application Note
How much bandwidth does your oscilloscope really need? Learn how to choose the correct bandwidth oscilloscope for your application.

Application Note 2014-04-23

ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note
Eye-diagram and pulse-shape pass/fail mask testing can be performed on differential ARINC 429 signals using a Keysight 3000 X-Series oscilloscope licensed with the DSOX3AERO and DSOX3MASK options.

Application Note 2014-04-21

PDF PDF 2.40 MB
Triggering on Infrequent Anomalies and Complex Signals using InfiniiScan Zone - Application Note
Learn how Keysight's exclusive InfiniiScan Zone touch trigger helps you trigger on infrequent anomalies and complex signals with ease.

Application Note 2014-04-21

Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity - Application Note
Make the most accurate digital measurements by learning how to evaluate oscilloscope sample rates vs. signal fidelity.

Application Note 2014-04-21

Waveform Update Rate Determines Probability of Capturing Elusive Events - Application Note
See how you can increase your odds of finding infrequent glitches with a high oscilloscope update rate.

Application Note 2014-04-18

Selecting the Right Scope for Protocol Analysis Applications - Application Note
When evaluating a new oscilloscope that will include serial protocol applications you should consider the six questions discussed in this application note.

Application Note 2014-04-17

PDF PDF 3.10 MB
Evaluating Oscilloscopes for Low-Power Measurements - Application Note
The Infiniium 9000 Series oscilloscope is three instruments in one: scope, logic analyzer, and protocol analyzer, and it offers the widest range of debug and compliance application software.

Application Note 2014-04-16

Evaluating Oscilloscope Signal Integrity - Application Note
This application note articulates key signal integrity attributes and uses Keysight Infiniium S-Series oscilloscopes for examples in the 500 MHz to 8 GHz bandwidth ranges.

Application Note 2014-04-15

MIL-STD 1553 Eye-diagram Mask Testing - Application Note
Learn about how eye-diagram testing can be performed on differential MIL-STD 1553 signals using an oscilloscope.

Application Note 2014-04-14

PDF PDF 1.86 MB
Debug Automotive Designs Faster with CAN-dbc Symbolic Trigger and Decode - Application Note
Learn about CAN-dbc symbolic triggering and how to improve debug of your automotive designs using an oscilloscope.

Application Note 2014-04-14

Switch Mode Power Supply Measurements - Application Note
Oscilloscope power measurement options provide a quick and easy way to analyze the reliability and efficiency of switching power supplies.

Application Note 2014-04-14

Physical Layer Testing of the USB 2.0 Serial Bus - Application Note
This application note discussed measurement requirements for the USB 2.0 serial bus and how both Keysight’s 6000 X-Series and Infiniium Series oscilloscopes address those challenges.

Application Note 2014-04-11

Using Oscilloscope Segmented Memory for Serial Bus Applications - Application Note
Learn how to use an oscilloscope's segmented memory to capture a longer time span and more serial packets while still digitizing at a high sample rate.

Application Note 2014-04-11

PDF PDF 1.90 MB
Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster - Application Note
Keysight's InfiniiVision Series oscilloscopes offer some unique measurement capabilities for debugging and characterizing the physical layer of automotive serial buses.

Application Note 2014-04-09

PDF PDF 3.03 MB
Oscilloscope Mask Testing for Six Sigma Quality Standards - Application Note
Learn about the QA process and Six Sigma efficiency, and explore the benefits mask testing brings to the QA process for electronic signals and achieving Six Sigma quality in as little as 1.1 seconds.

Application Note 2014-04-03

Automotive Serial Bus Testing - Application Note
This application note will show examples of characterizing the performance of various automotive serial buses using Keysight oscilloscopes and provide a summary of recommended probing solutions.

Application Note 2014-03-17

Jitter Analysis Using Keysight's InfiniiVision 6000 X-Series and Infiniium Series - Application Note
A discussion of various display formats used to view jitter including horizontal waveform histograms, TIE histograms, TIE trend waveforms, and jitter spectrum waveforms.

Application Note 2014-03-12

Characterizing Hi-speed USB 2.0 Serial Buses in Embedded Designs - Application Note
Learn about probing the hi-speed USB 2.0 serial bus and see some unique debugging tools and capabilities that can help you get your embedded designs to market faster.

Application Note 2014-03-03

CAN Eye-Diagram Mask Testing - Application Note
InfiniiVision X-Series scopes can trigger, decode, and perform eye-diagram mask test measurements on differential CAN bus signals, as well as perform analysis on other serial bus standards.