전문가 상담

기술 지원

전자 측정

모델번호로 검색: 예제: 34401A, E4440A

51-75 / 736

정렬방식:
N4962A Serial BERT 12.5 Gb/s - Data Sheet
The N4962A is a low cost 0.5 to 12.5 Gb/s pseudo-random bit sequence generator and bit error rate tester designed for automated production-line testing, manufacturing, and R&D use.

데이터시트 2014-08-25

IEEE 802.3 Ethernet KR/CR Compliance and Debug Applications - Data Sheet
This easy-to-use oscilloscope app helps you understand the details of standards; reduce your IEEE 802.3 test times from hours to minutes; and debug your device using custom configurations.

데이터시트 2014-08-04

PDF PDF 2.61 MB
N5435A Infiniium Server-Based License for Infiniium Oscilloscopes - Data Sheet
The N5435A Infiniium server-based license allows you to move your oscilloscope application license from one Infiniium oscilloscope to another, using a license server.

데이터시트 2014-08-04

N1021B 18 GHz Differential TDR Probe Kit - Data Sheet
The TDR 18 GHz differential TDR probe kit gives you connectivity to printed circuit boards and other devices without connectors.

데이터시트 2014-08-03

E5052B Signal Source Analyzer - Data Sheet
This 21-page data sheet provides technical specifications for the E5052B (10 MHz to 7 GHz) signal source analyzer and the E5053A Downconverter (3 GHz to 26.5 GHz). The E5052B is a single-instrument solution that offers an indispensable set of measurement functions for evaluating RF & microwave signal sources such as VCOs, crystal oscillators, SAW oscillators, dielectric resonator oscillators, YIG oscillators, PLL synthesizers, RFICs, and L.O. circuits.

데이터시트 2014-08-03

PDF PDF 1.87 MB
USB 2.0 Compliance Testing with Infiniium Oscilloscopes - Application Note
This Application Note discusses the solution for the USB 2.0 test suite. The Keysight solution is the only one-box solution that uses the official USB-IF scripts for precompliance ans compliance testing.

어플리케이션 노트 2014-08-03

DCA Probes and Accessories - Technical Overview
See recommended DCA probes and accessories for sampling oscilloscopes.

기술 개요 2014-08-03

PDF PDF 3.70 MB
8163B Lightwave Multimeter, 8164B Measurement System, 8166B Multichannel - Technical Specifications
Lightwave,Multimeter,Lightwave,Measurement,System,Lightwave,Multichannel,System

데이터시트 2014-08-03

PDF PDF 198 KB
86116C 40 to 65 GHz Optical and 80 GHz Electrical Plug-in Modules - Brochure
Keysight 86116C 40 to 65 GHz Optical and 80 GHz Electrical Plug-in Modules for the 86100C DCA-J wideband oscilloscope. 86116C-025 optimized for high-speed LAN/SAN signals. 86116C-040 optimized for high-speed telecom signals.

브로셔 2014-08-02

PDF PDF 389 KB
Bandwidth and Rise Time Requirements for Making Accurate Oscilloscope Measurements
How much oscilloscope bandwidth do you need and how fast does the rise time need to be to measure your signals accurately?

어플리케이션 노트 2014-08-02

PDF PDF 724 KB
SATA II Drive TX/RX Testing & Cable SI Testing Using the 86100C DCA-J - Technical Overview
SATA II Drive Tx/Rx Testing & Cable SI Test using 86100C DCA-J. Product Note 86100-8

어플리케이션 노트 2014-08-02

PDF PDF 1.94 MB
N5392A Ethernet Electrical Performance Validation and Compliance Software - Data Sheet
The Keysight Technologies N5392A Ethernet electrical performance validation and compliance software for Infiniium 54830 and 54850 Series oscilloscopes provides you with a fast and easy way to verify and debug your 1000Base-T, 100Base-TX and 10Base-T Ethernet designs. The Ethernet electrical test software

데이터시트 2014-08-01

N1010A FlexDCA Virtual Device Demonstration
This 3-minute video shows how the Keysight N1010A FlexDCA software can help semiconductor companies sell high-speed semiconductors

기본 데모 2014-08-01

86100D Option 201 Advanced Waveform Analysis Software - Product Fact Sheet
Keysight 86100C Option 201 Advanced Waveform Analysis Software. Option 201 offers breakthrough insights and faster standard compliance measurements such as Transmitter Waveform Dispersion Penalty (TWDP)

데이터시트 2014-07-31

PDF PDF 1.25 MB
Understanding Oscilloscope Frequency Response & Its Effect on Rise-Time Accuracy - Application Note
In this application note, we review the properties of both Gaussian and flat-response oscilloscopes, then discuss rise time accuracy for each response type. We show that flat-response oscilloscope, give more accurate rise-time measurement than a Gaussian-response oscilloscope of equal bandwidth, and we show you how to estimate the bandwidth you need. The application note will show you which type of frequency response offers the best measurement accuracy; there are two issues to consider, the maximum signal frequency, and the oscilloscope sampling alias errors. It will also determine how much bandwidth you need.

어플리케이션 노트 2014-07-31

86115D Multi-Port Plug-In Module for High-Volume/Parallel Optical Transceiver Test - Data Sheet
The 86115D is the ideal solution for high volume waveform analysis of transceivers operating, they Dramatically reduce the cost of test with high throughput test configurations

데이터시트 2014-07-31

N1010A De-Embedding Software - Data Sheet
N1010A FlexDCA Remote Access Software provides oscilloscope, eye/mask and jitter mode measurement capabilities on your PC. The powerful new software application provides offline and connected measurement capability for both the 86100C DCA-J and 86100D DCA-X oscilloscopes.

데이터시트 2014-07-31

PDF PDF 205 KB
Keysight L4610A PRM - 34B Radio Test Set - Brochure
Rugged, portable, radio test set provides true one-button operational testing of SINCGARS radios

브로셔 2014-07-31

PDF PDF 1.53 MB
Time Domain Reflectometry Theory - Application Note
When compared to other measurement techniques, time domain reflectometry provides a more intuitive and direct look at the DUT's characteristics.

어플리케이션 노트 2014-07-31

15431A Filter Set for 81150A - Data Sheet
The Agilent 15431A is a filter set for the 81150A. It generates the random jitter profile for testing PCI Express 2.0 receivers. To be used in conjunction with the N4903A.

데이터시트 2014-07-31

PDF PDF 1.09 MB
81133A and 81134A, 3.35 GHz Pulse Pattern Generators - Data Sheet
81133A and 81134A 3.35 GHz Pulse Pattern Generators. The need for pulse and pattern generation is fundamental to any device characterization task.The ability to emulate the pulse and pattern conditions to which the device will be subjected is essential.This emulation should include both typical and worst case conditions.Such accurate emulation requires superlative signal integrity and timing performance along with full control over parameters that allow specific worst case testing.

데이터시트 2014-07-31

PDF PDF 1.41 MB
86100CU-400 86100DU-400 PLL and Jitter Spectrum Measurement Software - Data Sheet
86100CU-Option 400 for the 86100C Infiniium Digital Communication Analyzer (DCA-J) is an advanced software application that makes fast, accurate, and repeatable phase locked loop (PLL)/jitter transfer measurements, using a precision jitter source and receiver.

데이터시트 2014-07-31

Understanding and Using Offset in InfiniiMax Active Probes - Application Note
This application note explains how offset is applied in the Keysight InfiniiMax Active Probes and how to use offset for various applications

어플리케이션 노트 2014-07-31

Introduces Industry's Most Accurate Test Solution for USB 3.1 Receivers
Achieve accurate receiver characterization with the J-BERT high-performance BERT

보도자료 2014-07-09

User's Guides, Programmer's Guides, and Online Help (Version 04.60.0024)
This installer places an "Keysight Infiniium Docs" folder shortcut on your desktop. In this folder you can find user's guides, programmer's guides, and other manuals that go with Infiniium 90000 Series and 9000 Series oscilloscope system software.

도움말 파일 2014-06-18

EXE EXE 239.71 MB

이전 1 2 3 4 5 6 7 8 9 10 ... 다음