Attenuation Measurement of Step Attenuators - Application Note 
Describes the T-matrix measurement method for achieving high accuracy in calibrating step attenuators.

アプリケーション・ノート 2015-05-20

PDF PDF 715 KB
Connector Pin Recession and its Effect on Network Analyzer Accuracy - White Paper 
Outlines an experiment undertaken to assess the impact on the measurement of reflection coefficient when using 3.5 mm connectors.

アプリケーション・ノート 2015-05-20

PDF PDF 406 KB
Uncertainty Analysis for Uncorrelated Input Quantities - White Paper 
The Guide to the Expression of Uncertainty in Measurement (GUM) has been widely adopted in the different fields of the industry and science. Learn how to use for uncorrelated input quantities.

アプリケーション・ノート 2015-05-19

PDF PDF 502 KB
Fully-Automatic DMM Calibration System - White Paper 
Describes a fully-automatic calibration system for digtial multimeters (DMMs), including the uncertainty estimation of DC Voltage measurements.

アプリケーション・ノート 2015-05-15

PDF PDF 1008 KB
Keysight Technologies スペクトラム・アナライザ測定を成功させる8つのヒント 
スペクトラム・アナライザはオシロスコープと同様、信号の観測に使用する基本測定器です。オシロスコープがタイム・ドメインの観測をするのに対し、スペクトラム・アナライザは周波数ドメインの観測をします。

アプリケーション・ノート 2015-05-13

A Guard-Band Strategy for Managing False-Accept Risk - White Paper 
Presents guard-band strategy for managing false-accept risk with only limited knowledge of the a priori probability that a device is in tolerance.

アプリケーション・ノート 2015-05-13

PDF PDF 260 KB
Defining Your Calibration Requirement - Technical Overview 
These are the steps that can be taken when actually placing an order to ensure you get a "proper" calibration.

技術概要 2015-05-12

PDF PDF 96 KB
Selecting a Calibration Vendor - Application Note 
Cost is important but are there any other questions that need to be asked in selecting a calibration supplier?

アプリケーション・ノート 2015-05-07

Paperless Calibration - Application Note 
Discusses the benefits of storing calibration records electronically rather than on paper in filing cabinets and explains why having a hard copy of these files is not necessary.

アプリケーション・ノート 2015-05-07

PDF PDF 86 KB
Evaluation of the Performance of a State-of-the-Art Digital Multimeter - White Paper 
Describes several methods used to verify the performance of a very accurate automatically calibrated DMM, the HP 3458A.

アプリケーション・ノート 2015-05-07

PDF PDF 864 KB
Instrument Design Validation and Recommended Calibration Policy - Application Note 
Provides background information on the test philosophies and methods used when developing instrument verification and adjustment procedures.

アプリケーション・ノート 2015-05-07

The Metrological & Financial Implications of a Clogged Fan Filter - Application Note 
This article discussed the implications of having a clogged air filter and addresses solutions to helping in the prevention of clogged air filters.

アプリケーション・ノート 2015-05-07

Language of Specifications - Application Note 
This paper explains some of the arcane language used in describing a product's characteristics.

アプリケーション・ノート 2015-05-07

PDF PDF 695 KB
Sensitivity Analysis of One-port Characterized Devices in Vector Network Analyzer Calibrations 
Results of a study on the use of characterized devices in microwave vector network analyzer (VNA) calibrations and measurements. A review of the theory of one-port characterized device calibration.

アプリケーション・ノート 2015-05-05

PDF PDF 290 KB
Too Much Calibration? - White Paper 
This paper explains the variables at work in the world of calibration - how they can be used to find the elusive balance point between cost and confidence, or "too much" and "not enough" calibration.

アプリケーション・ノート 2015-05-05

PDF PDF 569 KB
Establishing Traceability for Quantities Derived from Multiple Traceable Quantities - White Paper 
Provides method of developing traceability for measurements (eg. phase noise) that have no SI units.

アプリケーション・ノート 2015-05-05

PDF PDF 413 KB
Peak Power Solutions Brochure for Radar and Wireless Applications - Brochure  
This peak power solutions brochure cover various radar & wireless applications. Get a summary of applications in this brochure and learn where to download the application note and videos accordingly.

ブローシャ 2015-04-30

PDF PDF 3.78 MB
Using a Manufacturer's Specification as a Type B Error Contribution - White Paper 
Examines the implications of using a manufacturer's specification in an uncertainty analysis; and how calibration laboratories use uncertainty data in their quality systems and customer-facing documents.

アプリケーション・ノート 2015-04-27

PDF PDF 1.03 MB
Isolating Frequency Measurement Error and Sourcing Frequency by Robert Leiby 
When performing a calibration, the risk of incorrectly declaring a device as in-tolerance (false-accept risk) is dependent upon several factors such as the specified tolerance limit and guard band.

アプリケーション・ノート 2015-04-27

PDF PDF 3.09 MB
Qualitative Assessment on the Effects of Damage Connectors & Interfaces in Fiber Optic Measurements 
To qualify or predict the effects of damaged fiber optic connectors or optical interfaces, a qualitative assessment can ensure that these connectors are kept in a condition of optimum performance.

アプリケーション・ノート 2015-04-24

PDF PDF 3.18 MB
Calibration Process Innovation Using Non-Required Guard Banded Testing by Richard Ogg 
Calibration services vary as to how to set the acceptance limits compared to the required tolerance. Using a guard band to reduce the acceptance limit will increase the confidence in the calibration.

アプリケーション・ノート 2015-04-24

PDF PDF 258 KB
Business Considerations of Equipment Refresh in a Calibration Laboratory - White Paper 
Calibration laboratories operate in a world of constant change, and this is never more evident than in the products that are requested to be calibrated.

アプリケーション・ノート 2015-04-21

Setting and Adjusting Instrument Calibration Intervals - Application Note 
This document explains how Keysight determines the recommended calibration interval, and why and how this can be extended or reduced.

アプリケーション・ノート 2015-04-21

Calibration of Time Base Oscillators - White Paper  
As more accurate clocks were produced, new uses of time measurement were explored. As new uses were discovered, the need for even more accurate clocks became apparent.

アプリケーション・ノート 2015-04-13

PDF PDF 250 KB
E8663D PSG RF Analog Signal Generator - Data Sheet 
This datasheet includes information on the E8663D PSG RF Analog Signal Generator.

データシート 2015-04-01

PDF PDF 3.22 MB